메뉴 건너뛰기




Volumn 136, Issue 2, 2009, Pages 118-126

Patient doses in CT Examinations in 18 countries: Initial results from international atomic energy agency projects

(20)  Muhogora, W E a   Ahmed, N A b   Beganovic, A c   Benider, A d   Ciraj Bjelac, O e   Gershan, V f   Gershkevitsh, E g   Grupetta, E h   Kharita, M H i   Manatrakul, N j   Milakovic, M k   Ohno, K l   Ben Omrane, L m   Ptacek, J n   Schandorf, C o   Shabaan, M S p   Stoyanov, D q   Toutaoui, N r   Wambani, J S s   Rehani, M M t  


Author keywords

[No Author keywords available]

Indexed keywords

ABDOMINAL RADIOGRAPHY; ADULT; AFRICA; ARTICLE; ASIA; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; DEVELOPING COUNTRY; DIAGNOSTIC IMAGING; DOSIMETRY; EASTERN EUROPE; HIGH RESOLUTION COMPUTER TOMOGRAPHY; HUMAN; NUCLEAR ENERGY; PELVIS RADIOGRAPHY; RADIATION DOSE; RADIATION DOSE DISTRIBUTION; RADIATION EXPOSURE; RADIATION MONITORING; RADIODIAGNOSIS; SPINE RADIOGRAPHY; THORAX RADIOGRAPHY;

EID: 69949125102     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/rpd/ncp144     Document Type: Article
Times cited : (47)

References (25)
  • 1
    • 0003574442 scopus 로고    scopus 로고
    • United Nations Scientific Committee on the Effects of Atomic Radiation, Report to the General assembly, Annex D: Medical radiation exposures New York: United Nations
    • United Nations Scientific Committee on the Effects of Atomic Radiation. Sources and effects of ionizing radiation. Report to the General assembly, Annex D: Medical radiation exposures (New York: United Nations) (2000).
    • (2000) Sources and effects of ionizing radiation
  • 3
    • 30844435919 scopus 로고    scopus 로고
    • Survey of computed tomography techniques and absorbed dose in Italian hospitals: A comparison between two methods to estimate DLP and the effective dose and to verify fulfilment to the diagnostic reference levels
    • Origgi, D., Vigorito, S., Villa, G., Belloni, M. and Tosi, G. Survey of computed tomography techniques and absorbed dose in Italian hospitals: A comparison between two methods to estimate DLP and the effective dose and to verify fulfilment to the diagnostic reference levels. Eur. Radiol. 16, 227-237 (2006).
    • (2006) Eur. Radiol , vol.16 , pp. 227-237
    • Origgi, D.1    Vigorito, S.2    Villa, G.3    Belloni, M.4    Tosi, G.5
  • 4
    • 0026694643 scopus 로고
    • Average radiation dose in standard CT examinations of the head: Results of the 1990 NEXT survey
    • Conway, B. J., McCrohan, J. L., Antonsen, R. G., Rueter, F. G., Slayton, R. J. and Suleiman, O. H. Average radiation dose in standard CT examinations of the head: Results of the 1990 NEXT survey. Radiology 184, 135-140 (1992).
    • (1992) Radiology , vol.184 , pp. 135-140
    • Conway, B.J.1    McCrohan, J.L.2    Antonsen, R.G.3    Rueter, F.G.4    Slayton, R.J.5    Suleiman, O.H.6
  • 5
    • 69949140026 scopus 로고    scopus 로고
    • Conference of Radiation Control Program Directors (CRCPD). Nationwide Evaluation of X-ray Trends (NEXT). Tabulation of graphical summary of 2000 survey of Computed Tomography. CRCPD Publication E-07-2 (2007) (Available at http://www.crcpd.org).
    • Conference of Radiation Control Program Directors (CRCPD). Nationwide Evaluation of X-ray Trends (NEXT). Tabulation of graphical summary of 2000 survey of Computed Tomography. CRCPD Publication E-07-2 (2007) (Available at http://www.crcpd.org).
  • 7
    • 33645989136 scopus 로고    scopus 로고
    • Paediatric and adult computed tomography practices and patient dose in Australia
    • Moss, M. and McLean, D. Paediatric and adult computed tomography practices and patient dose in Australia. Australasian Radiol. 50 (1), 33-40 (2006).
    • (2006) Australasian Radiol , vol.50 , Issue.1 , pp. 33-40
    • Moss, M.1    McLean, D.2
  • 8
    • 33747620740 scopus 로고    scopus 로고
    • Dose reduction in CT while maintaining diagnostic confidence: Diagnostic reference levels at routine, head, chest and abdominal CT-IAEA coordinated research project
    • Tsapaki, V. et al. Dose reduction in CT while maintaining diagnostic confidence: Diagnostic reference levels at routine, head, chest and abdominal CT-IAEA coordinated research project. Radiology 240, 828-834 (2006).
    • (2006) Radiology , vol.240 , pp. 828-834
    • Tsapaki, V.1
  • 9
    • 69949171264 scopus 로고    scopus 로고
    • European Commission. European Guidelines on quality criteria for computed tomography. EUR 16262 EN, Luxembourg (1999).
    • European Commission. European Guidelines on quality criteria for computed tomography. EUR 16262 EN, Luxembourg (1999).
  • 10
    • 69949114571 scopus 로고    scopus 로고
    • Luxemborg , Available at, Accessed on 16 May 2005
    • European Commission. European Quality Criteria for Multislice CT. Luxemborg (2004) (Available at http://www.msct.eu/ CT_Quality_Criteria.htm). Accessed on 16 May 2005.
    • (2004) European Quality Criteria for Multislice CT
  • 11
    • 40049109570 scopus 로고    scopus 로고
    • Managing patient dose in multi-detector computed tomography (MDCT)
    • International Commission on Radiological Protection
    • International Commission on Radiological Protection. Managing patient dose in multi-detector computed tomography (MDCT). ICRP Publication 102. Ann. ICRP 37(1) (2007).
    • (2007) ICRP Publication 102. Ann. ICRP , vol.37 , Issue.1
  • 13
    • 0035174013 scopus 로고    scopus 로고
    • Managing patient dose in computed tomography. ICRP publication 87
    • International Commission on Radiological Protection
    • International Commission on Radiological Protection. Managing patient dose in computed tomography. ICRP publication 87. Ann. ICRP 30(4) (2001).
    • (2001) Ann. ICRP , vol.30 , Issue.4
  • 14
    • 0034603390 scopus 로고    scopus 로고
    • Radiation doses in computed tomography
    • Rehani, M. M. and Berry, M. Radiation doses in computed tomography BMJ 320, 593-594 (2000).
    • (2000) BMJ , vol.320 , pp. 593-594
    • Rehani, M.M.1    Berry, M.2
  • 15
    • 69949155394 scopus 로고    scopus 로고
    • Imaging Performance and Assessment of CT scanners (ImPACT, CT patient dosimetry Excel spreadsheet version 0.99x 20/01/06, Available at
    • Imaging Performance and Assessment of CT scanners (ImPACT). CT patient dosimetry Excel spreadsheet (version 0.99x 20/01/06) (Available at http://www.impactscan.org/ctdosimetry.htm).
  • 17
    • 0035143460 scopus 로고    scopus 로고
    • Minimizing radiation dose for pediatric body applications of single-detector helical CT: Strategies at a large children's hospital
    • Donnelly, L. F., Emery, K. H., Brody, A. S., Laor, T., Glylys-Monin, V. M., Anton, C. G., Thomas, S. R. and Frush, D. P. Minimizing radiation dose for pediatric body applications of single-detector helical CT: strategies at a large children's hospital. Am. J. Roentgenol. 176 303-306 (2001).
    • (2001) Am. J. Roentgenol , vol.176 , pp. 303-306
    • Donnelly, L.F.1    Emery, K.H.2    Brody, A.S.3    Laor, T.4    Glylys-Monin, V.M.5    Anton, C.G.6    Thomas, S.R.7    Frush, D.P.8
  • 19
    • 84992861239 scopus 로고    scopus 로고
    • Radiological protection and safety in medicine. ICRP Publication 73
    • International Commission on Radiological Protection
    • International Commission on Radiological Protection. Radiological protection and safety in medicine. ICRP Publication 73. Ann. ICRP 26 (2) (1996).
    • (1996) Ann. ICRP , vol.26 , Issue.2
  • 20
    • 21244494043 scopus 로고    scopus 로고
    • Implementation of DRLs in the UK
    • Wall, B. F. Implementation of DRLs in the UK. Radiat. Prot. Dosim. 114 (1-3), 183-187 (2005).
    • (2005) Radiat. Prot. Dosim , vol.114 , Issue.1-3 , pp. 183-187
    • Wall, B.F.1
  • 23
    • 27744501051 scopus 로고    scopus 로고
    • Patient dose reduction in CT
    • Lewis, M. A. and Edyvean, S. Patient dose reduction in CT. Br. J. Radiol. 78, 880-883 (2005).
    • (2005) Br. J. Radiol , vol.78 , pp. 880-883
    • Lewis, M.A.1    Edyvean, S.2
  • 24
    • 0042845953 scopus 로고    scopus 로고
    • Linton, O. W. and Mettler, F. A. National conference on dose reduction in CT with an emphasis on pediatric patients. Am. J. Rontgenol. 181, 321-329 (2003).
    • Linton, O. W. and Mettler, F. A. National conference on dose reduction in CT with an emphasis on pediatric patients. Am. J. Rontgenol. 181, 321-329 (2003).
  • 25
    • 0344961317 scopus 로고    scopus 로고
    • What needs to be done about reducing patient doses from CT? The North American approach
    • Wall, B. F. What needs to be done about reducing patient doses from CT? The North American approach. Br. J. Radiol. 76, 763-765 (2003).
    • (2003) Br. J. Radiol , vol.76 , pp. 763-765
    • Wall, B.F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.