메뉴 건너뛰기




Volumn 23, Issue 5, 2009, Pages 688.e11-688.e13

Use of the Starclose Device for Closure of Inadvertent Subclavian Artery Punctures

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTERIOTOMY; ARTERY CATHETERIZATION; ARTERY INJURY; ARTICLE; CASE REPORT; CENTRAL VENOUS CATHETER; DEVICE; FLUOROSCOPY; HUMAN; MALE; PRIORITY JOURNAL; SUBCLAVIAN ARTERY;

EID: 69749104945     PISSN: 08905096     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.avsg.2009.06.005     Document Type: Article
Times cited : (13)

References (11)
  • 1
    • 0024244014 scopus 로고
    • Complications associated with central venous catheters. A survey
    • Scott W.L. Complications associated with central venous catheters. A survey. Chest 94 (1988) 1221-1224
    • (1988) Chest , vol.94 , pp. 1221-1224
    • Scott, W.L.1
  • 2
    • 33750874453 scopus 로고    scopus 로고
    • The StarClose vascular closure system: interventional results from the CLIP study
    • Hermiller J.B., Simonton C., Hinohara T., et al. The StarClose vascular closure system: interventional results from the CLIP study. Catheter Cardiovasc Interv 68 (2006) 677-683
    • (2006) Catheter Cardiovasc Interv , vol.68 , pp. 677-683
    • Hermiller, J.B.1    Simonton, C.2    Hinohara, T.3
  • 4
    • 34250217726 scopus 로고    scopus 로고
    • Percutaneous closure after inadvertent subclavian artery cannulation
    • Shetty S.V., Kwolek C.J., and Garasic J.M. Percutaneous closure after inadvertent subclavian artery cannulation. Catheter Cardiovasc Interv 69 (2007) 1050-1052
    • (2007) Catheter Cardiovasc Interv , vol.69 , pp. 1050-1052
    • Shetty, S.V.1    Kwolek, C.J.2    Garasic, J.M.3
  • 5
    • 69749113070 scopus 로고    scopus 로고
    • Management of inadvertent carotid artery sheath insertion during jugular venous cannulation for pulmonary artery catheter placement: A comparison of operative and endovascular treatment
    • Presented at the, Available at
    • Bechara CF, Bismuth J, Cheng C, et al. Management of inadvertent carotid artery sheath insertion during jugular venous cannulation for pulmonary artery catheter placement: a comparison of operative and endovascular treatment. Presented at the SCVS Annual Meeting, Las Vegas, NV, 2008. Available at http://www.scvs.vascularweb.org/SCVS_Contribution_pages/2008Program.html
    • (2008) SCVS Annual Meeting, Las Vegas, NV
    • Bechara, C.F.1    Bismuth, J.2    Cheng, C.3    et al4
  • 6
    • 33846918207 scopus 로고    scopus 로고
    • Subclavian artery puncture repair with Angio-Seal deployment
    • Micha J.P., Goldstein B.H., Lindsay S.F., et al. Subclavian artery puncture repair with Angio-Seal deployment. Gynecol Oncol 104 (2007) 761-763
    • (2007) Gynecol Oncol , vol.104 , pp. 761-763
    • Micha, J.P.1    Goldstein, B.H.2    Lindsay, S.F.3
  • 7
    • 33845428368 scopus 로고    scopus 로고
    • Closure of the subclavian artery puncture site with a percutaneous suture device after removal of an arterial pacemaker lead
    • Meyhoefer J., Lehmann H., Minden H.H., and Butter C. Closure of the subclavian artery puncture site with a percutaneous suture device after removal of an arterial pacemaker lead. Europace 8 (2006) 1070-1072
    • (2006) Europace , vol.8 , pp. 1070-1072
    • Meyhoefer, J.1    Lehmann, H.2    Minden, H.H.3    Butter, C.4
  • 8
    • 11244261264 scopus 로고    scopus 로고
    • The use of a collagen-based puncture closure device in the subclavian artery after inadvertent introduction of an 11.5 French hemodialysis catheter
    • Railo M., and Roth W.D. The use of a collagen-based puncture closure device in the subclavian artery after inadvertent introduction of an 11.5 French hemodialysis catheter. Cardiovasc Intervent Radiol 27 (2004) 681-682
    • (2004) Cardiovasc Intervent Radiol , vol.27 , pp. 681-682
    • Railo, M.1    Roth, W.D.2
  • 9
    • 1242319454 scopus 로고    scopus 로고
    • Managing inadvertent arterial catheterization during central venous access procedures
    • Nicholson T., Ettles D., and Robinson G. Managing inadvertent arterial catheterization during central venous access procedures. Cardiovasc Intervent Radiol 27 (2004) 21-25
    • (2004) Cardiovasc Intervent Radiol , vol.27 , pp. 21-25
    • Nicholson, T.1    Ettles, D.2    Robinson, G.3
  • 10
    • 0037678449 scopus 로고    scopus 로고
    • Use of a percutaneous vascular suture device for closure of an inadvertent subclavian artery puncture
    • Fraizer M.C., Chu W.W., Gudjonsson T., and Wolff M.R. Use of a percutaneous vascular suture device for closure of an inadvertent subclavian artery puncture. Catheter Cardiovasc Interv 59 (2003) 369-371
    • (2003) Catheter Cardiovasc Interv , vol.59 , pp. 369-371
    • Fraizer, M.C.1    Chu, W.W.2    Gudjonsson, T.3    Wolff, M.R.4
  • 11
    • 0035011441 scopus 로고    scopus 로고
    • Closure using a surgical closure device of inadvertent subclavian artery punctures during central venous catheter placement
    • Berlet M.H., Steffen D., Shaughness G., and Hanner J. Closure using a surgical closure device of inadvertent subclavian artery punctures during central venous catheter placement. Cardiovasc Intervent Radiol 24 (2001) 122-124
    • (2001) Cardiovasc Intervent Radiol , vol.24 , pp. 122-124
    • Berlet, M.H.1    Steffen, D.2    Shaughness, G.3    Hanner, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.