메뉴 건너뛰기




Volumn 140, Issue 8, 2009, Pages 1013-1017

The validity of pulp testing: A clinical study

Author keywords

Dental pulp test; Diagnostic tests; Endodontic therapy

Indexed keywords


EID: 69749094492     PISSN: 00028177     EISSN: None     Source Type: Journal    
DOI: 10.14219/jada.archive.2009.0312     Document Type: Article
Times cited : (88)

References (13)
  • 1
    • 0033145268 scopus 로고    scopus 로고
    • Evaluation of the ability of thermal and electrical tests to register pulp vitality
    • Petersson K, Soderstrom C, Kiani-Anaraki M, Levy G. Evaluation of the ability of thermal and electrical tests to register pulp vitality. Endod Dent Traumatol 1999;15(3):127-131.
    • (1999) Endod Dent Traumatol , vol.15 , Issue.3 , pp. 127-131
    • Petersson, K.1    Soderstrom, C.2    Kiani-Anaraki, M.3    Levy, G.4
  • 2
    • 50549213652 scopus 로고
    • The dynamics of pulp inflammation: Correlations between diagnostic data and actual histologic findings in the pulp
    • Seltzer S, Bender IB, Ziontz M. The dynamics of pulp inflammation: correlations between diagnostic data and actual histologic findings in the pulp. Oral Surg Oral Med Oral Pathol 1963;16:969-977.
    • (1963) Oral Surg Oral Med Oral Pathol , vol.16 , pp. 969-977
    • Seltzer, S.1    Bender, I.B.2    Ziontz, M.3
  • 3
    • 0028527485 scopus 로고
    • Adult pulpal diagnosis, part I: Evaluation of the positive and negative responses to cold and electrical pulp tests
    • Peters DD, Baumgartner JC, Lorton L. Adult pulpal diagnosis, part I: evaluation of the positive and negative responses to cold and electrical pulp tests. J Endod 1994;20(10):506-511.
    • (1994) J Endod , vol.20 , Issue.10 , pp. 506-511
    • Peters, D.D.1    Baumgartner, J.C.2    Lorton, L.3
  • 4
    • 0022568560 scopus 로고
    • Assessment of reliability of electrical and thermal pulp testing agents
    • Fuss Z, Trowbridge H, Bender IB, Rickoff B, Sorin S. Assessment of reliability of electrical and thermal pulp testing agents. J Endod 1986;12(7):301-305.
    • (1986) J Endod , vol.12 , Issue.7 , pp. 301-305
    • Fuss, Z.1    Trowbridge, H.2    Bender, I.B.3    Rickoff, B.4    Sorin, S.5
  • 5
    • 0018912581 scopus 로고
    • Clinical signs and symptoms in pulp disease
    • Dummer PM, Hicks R, Huws D. Clinical signs and symptoms in pulp disease. Int Endod J 1980;13(l):27-35.
    • (1980) Int Endod J , vol.13 , Issue.1 , pp. 27-35
    • Dummer, P.M.1    Hicks, R.2    Huws, D.3
  • 8
    • 0027616199 scopus 로고
    • Reliability of electric pulp testing after pulpal testing with dichlorodifluoromethane
    • Pantera EA, Anderson RW, Pantera CT. Reliability of electric pulp testing after pulpal testing with dichlorodifluoromethane. J Endod 1993;19(6):312-314.
    • (1993) J Endod , vol.19 , Issue.6 , pp. 312-314
    • Pantera, E.A.1    Anderson, R.W.2    Pantera, C.T.3
  • 9
    • 0033202553 scopus 로고    scopus 로고
    • Effect of the type carrier used on the results of dichlorodifluoromethane application to teeth
    • Jones DM. Effect of the type carrier used on the results of dichlorodifluoromethane application to teeth. J Endod 1999;25(10): 692-694.
    • (1999) J Endod , vol.25 , Issue.10 , pp. 692-694
    • Jones, D.M.1
  • 10
    • 0032016244 scopus 로고    scopus 로고
    • Demonstration of a possible source of error with an electric pulp tester
    • Myers JW. Demonstration of a possible source of error with an electric pulp tester. J Endod 1998;24(3): 199-200.
    • (1998) J Endod , vol.24 , Issue.3 , pp. 199-200
    • Myers, J.W.1
  • 11
    • 0024093440 scopus 로고
    • Effects of thermal vitality tests on human dental pulp
    • Rickoff B, Trowbridge H, Fuss Z, Bender IB. Effects of thermal vitality tests on human dental pulp. J Endod 1988;14(10):482-485.
    • (1988) J Endod , vol.14 , Issue.10 , pp. 482-485
    • Rickoff, B.1    Trowbridge, H.2    Fuss, Z.3    Bender, I.B.4
  • 12
    • 0019546918 scopus 로고
    • 2 snow on intrapulpal temperature
    • 2 snow on intrapulpal temperature. J Endod 1981;7(3):110-116.
    • (1981) J Endod , vol.7 , Issue.3 , pp. 110-116
    • Augsburger, R.A.1    Peters, D.D.2
  • 13
    • 0024721631 scopus 로고
    • The reliability of electrical and thermal pulp tests: A clinical study [in Greek]
    • Georgopoulou M, Kerani M. The reliability of electrical and thermal pulp tests: a clinical study [in Greek]. Stomatologia (Athenai) 1989;46(5):317-326.
    • (1989) Stomatologia (Athenai) , vol.46 , Issue.5 , pp. 317-326
    • Georgopoulou, M.1    Kerani, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.