메뉴 건너뛰기




Volumn 7309, Issue , 2009, Pages

Evaluation of a passive millimeter wave (PMMW) imager for wire detection in degraded visual conditions

Author keywords

Brown out; Ddegraded visual conditions; Imaging; Millimeter Wave; Passive millimeter wave; Wire detection

Indexed keywords

BROWN-OUT; COMMERCIAL OFF THE SHELVES; DATA COLLECTION; DDEGRADED VISUAL CONDITIONS; DIGITAL RECORDING SYSTEM; GPS DATA; IMAGING; LAND ROVERS; LONGWAVE INFRARED; PASSIVE MILLIMETER WAVE; POWER LINES; REDUCED VISIBILITY; SPECIFIC SITES; TRANSITION PERIOD; VISIBLE IMAGING; VISIBLE SENSORS; VISUAL CONDITION; WEATHER CONDITIONS;

EID: 69549118716     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.820827     Document Type: Conference Paper
Times cited : (24)

References (17)
  • 1
    • 0029713382 scopus 로고    scopus 로고
    • Infrared thermography at EDF : A common technique for high-voltage lines but new in monitoring and diagnosis of PWR plant components
    • Provost, D., "Infrared thermography at EDF : a common technique for high-voltage lines but new in monitoring and diagnosis of PWR plant components", Proc. SPIE 2766, 83-90, (1996).
    • (1996) Proc. SPIE 2766 , pp. 83-90
    • Provost, D.1
  • 3
    • 0141750351 scopus 로고    scopus 로고
    • A radar cross-Section model for power lines at millimeter-Wave frequencies
    • Sarabandi, K. and Park, M., "A Radar Cross-Section Model for Power Lines at Millimeter-Wave Frequencies", IEEE Trans. on Ant. and Prop., 51(9), 2353-2360, (2003).
    • (2003) IEEE Trans. on Ant. and Prop. , vol.51 , Issue.9 , pp. 2353-2360
    • Sarabandi, K.1    Park, M.2
  • 4
    • 69549149302 scopus 로고    scopus 로고
    • http://www.ioindustries.com
  • 5
    • 69549152727 scopus 로고    scopus 로고
    • http//:www.xybioncameras.com
  • 6
    • 69549145754 scopus 로고    scopus 로고
    • http://www.indigosystems.com
  • 8
    • 69549147008 scopus 로고    scopus 로고
    • http://aluminium.matter.org.uk/content/html/ENG/default.asp?catid= 164&pageid=2144416510
  • 13
    • 39149121444 scopus 로고    scopus 로고
    • Optical attenuation in fog at a wavelength of 1.55 micrometers
    • Fischer, K.W., Witiw, M.R. and Eisenberg, E. "Optical attenuation in fog at a wavelength of 1.55 micrometers, Atmospheric Research", 252-258, (2008).
    • (2008) Atmospheric Research , pp. 252-258
    • Fischer, K.W.1    Witiw, M.R.2    Eisenberg, E.3
  • 15
    • 50949101692 scopus 로고    scopus 로고
    • Transmission line conductor temperature impact on state estimation accuracy
    • Bockarjova, M., and anderson, G., "Transmission Line Conductor Temperature Impact on State Estimation Accuracy", Power Tech 2007 IEEE Lausanne, 701-706, (2007).
    • (2007) Power Tech 2007 IEEE Lausanne , pp. 701-706
    • Bockarjova, M.1    Anderson, G.2
  • 17
    • 69549142616 scopus 로고    scopus 로고
    • http://www.hrl.com/media/hemt/hemt-cmrcl.html


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.