메뉴 건너뛰기




Volumn 7318, Issue , 2009, Pages

Microfabrication of nanowires-based GMR biosensor

Author keywords

Ferrofluid; Giant magnetoresistance (GMR); Hall measurements; Magnetic field; Microfluidic sensor

Indexed keywords

EXTERNAL MAGNETIC FIELD; FERROFLUID; HALL MEASUREMENTS; IN-CELL; MAGNETIC NANOPARTICLES; MICRO-FLUIDIC SENSORS; MICROFLUIDIC BIOSENSORS; MICROFLUIDIC SENSOR; MULTI-LAYERED; NONMAGNETIC MEDIUM; PROTOTYPE DEVICES; RESISTANCE CHANGE;

EID: 69549116873     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.819076     Document Type: Conference Paper
Times cited : (2)

References (17)
  • 1
    • 0001474380 scopus 로고    scopus 로고
    • Magnetic materials and structures for thin-film recording media
    • Johnson, K. E., "Magnetic materials and structures for thin-film recording media, " J. Appl. Phys., 87, 5365 (2000).
    • (2000) J. Appl. Phys. , vol.87 , pp. 5365
    • Johnson, K.E.1
  • 2
    • 11944262717 scopus 로고
    • Large magnetoresistance at room temperature in ferromagnetic thin film tunnel junctions
    • Moodera, Kinder, L. R., Wong, T. M., and Merservey, R., "Large magnetoresistance at room temperature in ferromagnetic thin film tunnel junctions, " Phys. Rev. Lett., 74, 3273 (1995).
    • (1995) Phys. Rev. Lett. , vol.74 , pp. 3273
    • Kinder, L.R.M.1    Wong, T.M.2    Merservey, R.3
  • 4
    • 12044259238 scopus 로고
    • Perpendicular giant magnetoresistance of microstructured Fe/Cr magnetic multilayers from 4.2 to 300 K
    • Gijs, M. A. M., Lenczowski, S. K. J., and Giesbers, J. B., "Perpendicular giant magnetoresistance of microstructured Fe/Cr magnetic multilayers from 4.2 to 300 K, " Phys. Rev. Lett., 70 (21), 3343 (1993).
    • (1993) Phys. Rev. Lett. , vol.70 , Issue.21 , pp. 3343
    • Gijs, M.A.M.1    Lenczowski, S.K.J.2    Giesbers, J.B.3
  • 5
    • 0000606628 scopus 로고    scopus 로고
    • Current perpendicular to plane giant magnetoresistance of multilayered nanowires electrodeposited in anodic aluminum oxide membranes
    • Evans, P. R., Yi, G., and Schwarzacher, W., "Current perpendicular to plane giant magnetoresistance of multilayered nanowires electrodeposited in anodic aluminum oxide membranes, " Appl. Phys. Lett., 76(4), 481 (2000).
    • (2000) Appl. Phys. Lett. , vol.76 , Issue.4 , pp. 481
    • Evans, P.R.1    Yi, G.2    Schwarzacher, W.3
  • 8
    • 0242364773 scopus 로고    scopus 로고
    • Design and performance of GMR sensors for the detection of magnetic microbeads in biosensors
    • Rife, J. C., Miller, M. M., Sheehan, P. E., Tamanaha, C. R., Tondra, M., and Whitman, L. J., "Design and performance of GMR sensors for the detection of magnetic microbeads in biosensors, " Sens. Actuators, A, 107, 209 (2003).
    • (2003) Sens. Actuators, A , vol.107 , pp. 209
    • Rife, J.C.1    Miller, M.M.2    Sheehan, P.E.3    Tamanaha, C.R.4    Tondra, M.5    Whitman, L.J.6
  • 9
    • 45849086137 scopus 로고    scopus 로고
    • Advances in giant magnetoresistance biosensors with magnetic nanoparticle tags: Review and outlook
    • Wang, S. X., and Li, G., "Advances in giant magnetoresistance biosensors with magnetic nanoparticle tags: Review and outlook, " IEEE Trans. Magn., 44, 1687 (2008).
    • (2008) IEEE Trans. Magn , vol.44 , pp. 1687
    • Wang, S.X.1    Li, G.2
  • 10
    • 10944247056 scopus 로고    scopus 로고
    • Giant magnetoresistance monitoring of magnetic picodroplets in an integrated microfluidic system
    • Pekas, N., Porter, M. D., Tondra, M., Popple, A., and Jander, A., "Giant magnetoresistance monitoring of magnetic picodroplets in an integrated microfluidic system", Appl. Phys. Lett., 85(20), 4783 (2004).
    • (2004) Appl. Phys. Lett. , vol.85 , Issue.20 , pp. 4783
    • Pekas, N.1    Porter, M.D.2    Tondra, M.3    Popple, A.4    Jander, A.5
  • 11
    • 42549125999 scopus 로고    scopus 로고
    • Determining the optimal PDMS-PDMS bonding technique for microfluidic devices
    • Eddings, M. A., Johnson, M. A., Gale, B. K., "Determining the optimal PDMS-PDMS bonding technique for microfluidic devices, " J. Micromech. Microeng., 18, 067001 (2008).
    • (2008) J. Micromech. Microeng. , vol.18 , pp. 067001
    • Eddings, M.A.1    Johnson, M.A.2    Gale, B.K.3
  • 13
    • 1642373750 scopus 로고    scopus 로고
    • Comparison of a prototype magnetoresistive biosensor to standard fluorescent DNA detection
    • Schotter, J., Kamp, P. B., Becker, A., Puhler, A., Reiss, G., and Bruckl, H., "Comparison of a prototype magnetoresistive biosensor to standard fluorescent DNA detection, " Biosens. Bioelectron., 19(10), 1149 (2004).
    • (2004) Biosens. Bioelectron. , vol.19 , Issue.10 , pp. 1149
    • Schotter, J.1    Kamp, P.B.2    Becker, A.3    Puhler, A.4    Reiss, G.5    Bruckl, H.6
  • 14
    • 0037094859 scopus 로고    scopus 로고
    • Single magnetic microsphere placement and detection on-chip using current line designs with integrated spin valve sensors: Biotechnological applications
    • Graham, D. L., Ferreira, H., Bernardo, J., Freitas, P. P., and Cabral, J. M. S., "Single magnetic microsphere placement and detection on-chip using current line designs with integrated spin valve sensors: Biotechnological applications, " J. Appl. Phys., 91, 7786 (2007).
    • (2007) J. Appl. Phys. , vol.91 , pp. 7786
    • Graham, D.L.1    Ferreira, H.2    Bernardo, J.3    Freitas, P.P.4    Cabral, J.M.S.5
  • 15
    • 36849067016 scopus 로고    scopus 로고
    • Biosensing: New probes offer much faster results
    • Sandhu, A., "Biosensing: New probes offer much faster results, " Nat. Nanotechnol., News and View, 2, 748 (2007).
    • (2007) Nat. Nanotechnol., News and View , vol.2 , pp. 748
    • Sandhu, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.