Volumn 56, Issue 4, 2009, Pages 2284-2289

A first application of the FRAM isotopic analysis code to high-resolution microcalorimetry gamma-ray spectra

Author keywords

Gamma rays; Gamma ray spectroscopy; Microcalorimetry; Plutonium

Indexed keywords

ADVANCED SOFTWARE PACKAGE; CRYOGENIC MICROCALORIMETER DETECTORS; GAMMA RAY SPECTRA; GAMMA-RAY SPECTROMETRY; GAMMA-RAY SPECTROSCOPY; HIGH RESOLUTION; HIGH-PURITY GERMANIUM; ISOTOPIC ANALYSIS; ISOTOPIC COMPOSITION; LOS ALAMOS NATIONAL LABORATORY; MICROCALORIMETRY; ORDER OF MAGNITUDE; SPECIAL NUCLEAR MATERIALS; X-RAY PEAKS;

EID: 69549088493     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2009.2022938     Document Type: Conference Paper
Times cited : (2)

References (12)
  • 1
    • 69549107919 scopus 로고
    • MGA: A Gamma-Ray Spectrum Analysis Code for Determining Plutonium Isotopic Abundances Volume I, Methods and Algorithms
    • Report UCRL-LR-103220 Task No. A.161
    • R. Gunnink, "MGA: A Gamma-Ray Spectrum Analysis Code for Determining Plutonium Isotopic Abundances, Volume I, Methods and Algorithms," Lawrence Livermore National Lab., Report UCRL-LR-103220, Vol I/ISPO, Task No. A.161, 1990.
    • (1990) Lawrence Livermore National Lab. , vol.1 ISPO
    • Gunnink, R.1
  • 2
    • 15944420872 scopus 로고    scopus 로고
    • Application Guide to Gamma-Ray Isotopic Analysis Using the FRAM Software
    • Document LA-14018
    • T. E. Sampson, T. A. Kelly, and D. T. Vo, "Application Guide to Gamma-Ray Isotopic Analysis Using the FRAM Software," Los Alamos National Lab., Document LA-14018, 2003.
    • (2003) Los Alamos National Lab.
    • Sampson, T.E.1    Kelly, T.A.2    Vo, D.T.3
  • 3
    • 69549125827 scopus 로고    scopus 로고
    • Generalization of FRAM's Bias
    • Report LA-14253
    • D. T. Vo, "Generalization of FRAM's Bias," Los Alamos National Lab., Report LA-14253, 2005.
    • (2005) Los Alamos National Lab.
    • Vo, D.T.1
  • 9
    • 69549133175 scopus 로고    scopus 로고
    • Large-area microcalorimeter detectors for ultra-high-resolution x- and gamma-ray spectroscopy
    • to be published
    • M. Bacrania et al., "Large-area microcalorimeter detectors for ultra-high-resolution x- and gamma-ray spectroscopy," SORMA WEST, 2008, to be published.
    • (2008) SORMA WEST
    • Bacrania, M.1
  • 12
    • 69549134916 scopus 로고    scopus 로고
    • The possibility of direct Pu measurements with cryogenic gamma-ray spectrometers
    • S. Alietal., "The possibility of direct Pu measurements with cryogenic gamma-ray spectrometers," in INMM Conf. Proc., 2006.
    • (2006) INMM Conf. Proc.
    • Alietal., S.1