메뉴 건너뛰기




Volumn 62, Issue 3, 2009, Pages 808-814

Elliptical field-of-view PROPELLER imaging

Author keywords

Elliptical FOV; Nonuniform angular sampling; PROPELLER

Indexed keywords

OPTICAL TRANSFER FUNCTION; PHANTOMS; PROPELLERS;

EID: 69449097889     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.22006     Document Type: Article
Times cited : (4)

References (13)
  • 1
    • 0028364190 scopus 로고
    • Reduction of field of view for dynamic imaging
    • DOI 10.1002/mrm.1910310618
    • Hu X, Parrish T. Reduction of field of view for dynamic imaging. Magn Reson Med 1994;31:691-694. (Pubitemid 24166826)
    • (1994) Magnetic Resonance in Medicine , vol.31 , Issue.6 , pp. 691-694
    • Hu, X.1    Parrish, T.2
  • 2
    • 0029856450 scopus 로고    scopus 로고
    • 2D locally focused MRI: Applications to dynamic and spectroscopic imaging
    • Yao L, Cao Y, Levin DN. 2D Locally focused MRI: applications to dynamic and spectroscopic imaging. Magn Reson Med 1996;36:834-846. (Pubitemid 26396811)
    • (1996) Magnetic Resonance in Medicine , vol.36 , Issue.6 , pp. 834-846
    • Yao, L.1    Cao, Y.2    Levin, D.N.3
  • 3
    • 0031850913 scopus 로고    scopus 로고
    • Reduced circular field-of-view imaging
    • Scheffler K, Hennig J. Reduced circular field-of-view imaging. Magn Reson Med 1998;40:474-480.
    • (1998) Magn Reson Med , vol.40 , pp. 474-480
    • Scheffler, K.1    Hennig, J.2
  • 4
    • 0033005053 scopus 로고    scopus 로고
    • Tomographic imaging with nonuniform angular sampling
    • DOI 10.1097/00004728-199901000-00032
    • Scheffler K. Tomographic imaging with nonuniform angular sampling. J Comput Assist Tomogr 1999;23:162-166. (Pubitemid 29095488)
    • (1999) Journal of Computer Assisted Tomography , vol.23 , Issue.1 , pp. 162-166
    • Scheffler, K.1
  • 6
    • 0031906299 scopus 로고    scopus 로고
    • Spiral scanning with anisotropic field of view
    • King KF. Spiral scanning with anisotropic field of view. Magn Reson Med 1998;39:448-456.
    • (1998) Magn Reson Med , vol.39 , pp. 448-456
    • King, K.F.1
  • 8
    • 0032754594 scopus 로고    scopus 로고
    • Motion correction with PROPELLER MRI: Application to head motion and free-breathing cardiac imaging
    • Pipe JG. Motion correction with PROPELLER MRI: Application to head motion and free-breathing cardiac imaging. Mag Reson Med 1999;42:963-969.
    • (1999) Mag Reson Med , vol.42 , pp. 963-969
    • Pipe, J.G.1
  • 9
    • 0001556554 scopus 로고
    • Modular equations and approximations to Pi
    • Oxford
    • Ramanujan S. Modular equations and approximations to Pi. Q J Math (Oxford) 1914;45:350-372.
    • (1914) Q J Math , vol.45 , pp. 350-372
    • Ramanujan, S.1
  • 11
    • 0026219520 scopus 로고
    • Selections of a convolution function for fourier inversion using gridding
    • Jackson JI, Meyer CH, Nishimura DG. Selections of a convolution function for fourier inversion using gridding. IEEE Trans Med Imaging 1991;10:473-478.
    • (1991) IEEE Trans Med Imaging , vol.10 , pp. 473-478
    • Jackson, J.I.1    Meyer, C.H.2    Nishimura, D.G.3
  • 12
    • 0032957342 scopus 로고    scopus 로고
    • Sampling density compensation in MRI: Rationale and an iterative numerical solution
    • DOI 10.1002/(SICI)1522-2594(199901)41:1<179::AID-MRM25>3.0.CO;2-V
    • Pipe JG, Menon P. Sampling density compensation in MRI: rationale and an iterative numerical solution. Mag Reson Med 1999;41:179-186. (Pubitemid 29068051)
    • (1999) Magnetic Resonance in Medicine , vol.41 , Issue.1 , pp. 179-186
    • Pipe, J.G.1    Menon, P.2
  • 13
    • 0032800940 scopus 로고    scopus 로고
    • A comparison of two methods for measuring the signal to noise ratio on MR images
    • Firbank MJ, Coulthard A, Harrison RM, Williams ED. A comparison of two methods for measuring the signal to noise ratio on MR images. Phys Med Biol 1999;44:N261-N264.
    • (1999) Phys Med Biol , vol.44
    • Firbank, M.J.1    Coulthard, A.2    Harrison, R.M.3    Williams, E.D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.