메뉴 건너뛰기




Volumn 42, Issue 13, 2009, Pages 2124-2128

The influence of concentric and eccentric loading on the finger pulley system

Author keywords

Biomechanics; Climbing; Eccentric concentric loading; Friction; Pulley rupture

Indexed keywords

CLIMBING; CONCENTRIC LOADING; ECCENTRIC LOADING; ECCENTRIC/CONCENTRIC LOADING; FINGER PULLEY SYSTEM; FLEXOR TENDON; LOADING CONDITION; LOADING DEVICES; PULLEY RUPTURE; PULLEY SYSTEMS;

EID: 69449095001     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2009.05.033     Document Type: Article
Times cited : (41)

References (35)
  • 1
    • 0023690478 scopus 로고
    • The interior of the flexor tendon sheath of the finger. The functional significance of its structure
    • Amis A.A., and Jones M.M. The interior of the flexor tendon sheath of the finger. The functional significance of its structure. J. Bone Joint Surg. (Br.) 70 (1988) 583-587
    • (1988) J. Bone Joint Surg. (Br.) , vol.70 , pp. 583-587
    • Amis, A.A.1    Jones, M.M.2
  • 2
    • 0025183031 scopus 로고
    • Injury to the A2 pulley in rock climbers
    • Bollen S.R. Injury to the A2 pulley in rock climbers. J. Hand Surg. (Br.) 15 (1990) 268-270
    • (1990) J. Hand Surg. (Br.) , vol.15 , pp. 268-270
    • Bollen, S.R.1
  • 3
    • 0028108917 scopus 로고
    • Closed traumatic rupture of finger flexor pulleys
    • Bowers W.H., Kuzma G.R., and Bynum D.K. Closed traumatic rupture of finger flexor pulleys. J. Hand Surg. (Am.) 19 (1994) 782-787
    • (1994) J. Hand Surg. (Am.) , vol.19 , pp. 782-787
    • Bowers, W.H.1    Kuzma, G.R.2    Bynum, D.K.3
  • 6
    • 0030221002 scopus 로고    scopus 로고
    • A tendon-locking mechanism in two climbing rodents, Muscardinus avellanarius and Micromys minutus (Mammalia, Rodentia)
    • Haffner M. A tendon-locking mechanism in two climbing rodents, Muscardinus avellanarius and Micromys minutus (Mammalia, Rodentia). J. Morphol. 229 (1996) 219-227
    • (1996) J. Morphol. , vol.229 , pp. 219-227
    • Haffner, M.1
  • 7
    • 0029658856 scopus 로고    scopus 로고
    • Die Ringbänder der fingerbeugesehnen. Anatomie, biomechanik, wiederherstellung
    • Hahn P., and Lanz U. Die Ringbänder der fingerbeugesehnen. Anatomie, biomechanik, wiederherstellung. Handchir Mikrochir Plast Chir 28 (1996) 265-270
    • (1996) Handchir Mikrochir Plast Chir , vol.28 , pp. 265-270
    • Hahn, P.1    Lanz, U.2
  • 9
    • 0029945156 scopus 로고    scopus 로고
    • Elbow, forearm, wrist, and hand injuries among sport rock climbers
    • Holtzhausen L.M., and Noakes T.D. Elbow, forearm, wrist, and hand injuries among sport rock climbers. Clin. J. Sport Med. 6 (1996) 196-203
    • (1996) Clin. J. Sport Med. , vol.6 , pp. 196-203
    • Holtzhausen, L.M.1    Noakes, T.D.2
  • 12
    • 0031845311 scopus 로고    scopus 로고
    • Pathomechanics of closed rupture of the flexor tendon pulleys in rock climbers
    • Marco R.A., Sharkey N.A., Smith T.S., and Zissimos A.G. Pathomechanics of closed rupture of the flexor tendon pulleys in rock climbers. J. Bone Joint Surg. (Am.) 80 (1998) 1012-1019
    • (1998) J. Bone Joint Surg. (Am.) , vol.80 , pp. 1012-1019
    • Marco, R.A.1    Sharkey, N.A.2    Smith, T.S.3    Zissimos, A.G.4
  • 13
    • 0029101887 scopus 로고
    • Biomechanics of the human flexor tendon sheath investigated by tenography
    • Mester S., Schmidt B., Derczy K., Nyarady J., and Biro V. Biomechanics of the human flexor tendon sheath investigated by tenography. J. Hand Surg. (Br.) 20 (1995) 500-504
    • (1995) J. Hand Surg. (Br.) , vol.20 , pp. 500-504
    • Mester, S.1    Schmidt, B.2    Derczy, K.3    Nyarady, J.4    Biro, V.5
  • 14
    • 0037309427 scopus 로고    scopus 로고
    • Flexor tendon pulley system: anatomy, pathology, treatment
    • Moutet F. Flexor tendon pulley system: anatomy, pathology, treatment. Chir. Main 22 (2003) 1-12
    • (2003) Chir. Main , vol.22 , pp. 1-12
    • Moutet, F.1
  • 15
    • 0032459929 scopus 로고    scopus 로고
    • Excursion properties of tendon graft sources: interaction between tendon and A2 pulley
    • Nishida J., Amadio P.C., Bettinger P.C., and An K.N. Excursion properties of tendon graft sources: interaction between tendon and A2 pulley. J. Hand Surg. (Am.) 23 (1998) 274-278
    • (1998) J. Hand Surg. (Am.) , vol.23 , pp. 274-278
    • Nishida, J.1    Amadio, P.C.2    Bettinger, P.C.3    An, K.N.4
  • 17
    • 0000261075 scopus 로고
    • The digital locking mechanism of the avian foot
    • Quinn T.H., and Baumel J.J. The digital locking mechanism of the avian foot. Zoomorphology 109 (1990) 281-293
    • (1990) Zoomorphology , vol.109 , pp. 281-293
    • Quinn, T.H.1    Baumel, J.J.2
  • 18
    • 0027603188 scopus 로고
    • Chiropteran tendon locking mechanism
    • Quinn T.H., and Baumel J.J. Chiropteran tendon locking mechanism. J. Morphol. 216 (1993) 197-208
    • (1993) J. Morphol. , vol.216 , pp. 197-208
    • Quinn, T.H.1    Baumel, J.J.2
  • 20
    • 69449105117 scopus 로고    scopus 로고
    • Roloff, I., 2004. (Biomechanical modelling of the climbers hand: estimation of the mechanical constrains applied on the finger flexor tendon pulleys) Modélisation biomécanique de la main du grimpeur: estimation des contraintes mécaniques exercées sur les poulies digitalis. Master 2 Technologie, homme et société mention sport, santé, société spécialité mouvement, performance, santé. Grenoble: Université Joseph Fourier Grenoble 1.
    • Roloff, I., 2004. (Biomechanical modelling of the climbers hand: estimation of the mechanical constrains applied on the finger flexor tendon pulleys) Modélisation biomécanique de la main du grimpeur: estimation des contraintes mécaniques exercées sur les poulies digitalis. Master 2 Technologie, homme et société mention sport, santé, société spécialité mouvement, performance, santé. Grenoble: Université Joseph Fourier Grenoble 1.
  • 21
    • 32644449945 scopus 로고    scopus 로고
    • Biomechanical model for the determination of the forces acting on the finger pulley system
    • Roloff I., Schöffl V.R., Vigouroux L., and Quaine F. Biomechanical model for the determination of the forces acting on the finger pulley system. J. Biomech. 39 (2006) 915-923
    • (2006) J. Biomech. , vol.39 , pp. 915-923
    • Roloff, I.1    Schöffl, V.R.2    Vigouroux, L.3    Quaine, F.4
  • 24
    • 33645991484 scopus 로고    scopus 로고
    • Strength measurement after conservatively treated pulley ruptures in climbers
    • Schöffl, V., Einwag, F., Strecker, W.,Schöffl, I., 2006. Strength measurement after conservatively treated pulley ruptures in climbers. Med. Sci. Sports Exerc. 38, 637-643.
    • (2006) Med. Sci. Sports Exerc , vol.38 , pp. 637-643
    • Schöffl, V.1    Einwag, F.2    Strecker, W.3    Schöffl, I.4
  • 27
    • 33646066872 scopus 로고    scopus 로고
    • Closed flexor pulley injuries in nonclimbing activities
    • Schoffl V.R., and Jungert J. Closed flexor pulley injuries in nonclimbing activities. J. Hand Surg. (Am.) 31 (2006) 806-810
    • (2006) J. Hand Surg. (Am.) , vol.31 , pp. 806-810
    • Schoffl, V.R.1    Jungert, J.2
  • 28
    • 0027715895 scopus 로고
    • Digital morphology in the chiroptera: the passive digital lock
    • Schutt Jr. W.A. Digital morphology in the chiroptera: the passive digital lock. Acta Anat. (Basel) 148 (1993) 219-227
    • (1993) Acta Anat. (Basel) , vol.148 , pp. 219-227
    • Schutt Jr., W.A.1
  • 29
    • 0037212673 scopus 로고    scopus 로고
    • Friction between human finger flexor tendons and pulleys at high loads
    • Schweizer A., Frank O., Ochsner P.E., and Jacob H.A. Friction between human finger flexor tendons and pulleys at high loads. J. Biomech. 36 (2003) 63-71
    • (2003) J. Biomech. , vol.36 , pp. 63-71
    • Schweizer, A.1    Frank, O.2    Ochsner, P.E.3    Jacob, H.A.4
  • 32
    • 0029057775 scopus 로고
    • An anatomical study of the mechanical interactions of flexor digitorum superficialis and profundus and the flexor tendon sheath in zone 2
    • Walbeehm E.T., and McGrouther D.A. An anatomical study of the mechanical interactions of flexor digitorum superficialis and profundus and the flexor tendon sheath in zone 2. J. Hand Surg. (Br.) 20 (1995) 269-280
    • (1995) J. Hand Surg. (Br.) , vol.20 , pp. 269-280
    • Walbeehm, E.T.1    McGrouther, D.A.2
  • 33
    • 0028860701 scopus 로고
    • A new type of flexor tendon repair. Biomechanical evaluation by cyclic loading, ultimate strength and assessment of pulley friction in vitro
    • Williams R.J., and Amis A.A. A new type of flexor tendon repair. Biomechanical evaluation by cyclic loading, ultimate strength and assessment of pulley friction in vitro. J. Hand Surg. (Br.) 20 (1995) 578-583
    • (1995) J. Hand Surg. (Br.) , vol.20 , pp. 578-583
    • Williams, R.J.1    Amis, A.A.2
  • 34
    • 0019788437 scopus 로고
    • The importance of controlled passive mobilization on flexor tendon healing. A biomechanical study
    • Woo S.L., Gelberman R.H., Cobb N.G., Amiel D., Lothringer K., and Akeson W.H. The importance of controlled passive mobilization on flexor tendon healing. A biomechanical study. Acta Orthop. (Scand.) 52 (1981) 615-622
    • (1981) Acta Orthop. (Scand.) , vol.52 , pp. 615-622
    • Woo, S.L.1    Gelberman, R.H.2    Cobb, N.G.3    Amiel, D.4    Lothringer, K.5    Akeson, W.H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.