메뉴 건너뛰기




Volumn 9, Issue 5, 2004, Pages 452-461

Clinical accuracy evaluation of femoral canal preparation using the ROBODOC system

Author keywords

Clinical accuracy evaluation; Femoral canal preparation; ORTHODOC; ROBODOC

Indexed keywords

ACCURACY; ADULT; AGED; ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; DEVICE; EVALUATION; FEMALE; HUMAN; MAJOR CLINICAL STUDY; MALE; PREOPERATIVE EVALUATION; TOTAL HIP PROSTHESIS;

EID: 6944229307     PISSN: 09492658     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00776-004-0804-5     Document Type: Article
Times cited : (46)

References (29)
  • 1
    • 0031719836 scopus 로고    scopus 로고
    • Primary and revision total hip replacement using the Robodoc system
    • Bargar WL, Bauer A, Börner M. Primary and revision total hip replacement using the Robodoc system. Clin Orthop 1998;354:82-91.
    • (1998) Clin Orthop , vol.354 , pp. 82-91
    • Bargar, W.L.1    Bauer, A.2    Börner, M.3
  • 2
    • 0036954034 scopus 로고    scopus 로고
    • Internal architecture of the proximal femur - Adam's or Adams' arch? Historical mystery
    • Bartonicek J. Internal architecture of the proximal femur - Adam's or Adams' arch? Historical mystery. Arch Orthop Trauma Surg 2002;122:551-3.
    • (2002) Arch Orthop Trauma Surg , vol.122 , pp. 551-553
    • Bartonicek, J.1
  • 3
    • 0028084810 scopus 로고
    • Ingrowth surfaces. Plasma spray coating to titanium alloy hip replacements
    • Bourne RB, Rorabeck CH, Burkart BC et al. Ingrowth surfaces. Plasma spray coating to titanium alloy hip replacements. Clin Orthop 1994;298:37-46.
    • (1994) Clin Orthop , vol.298 , pp. 37-46
    • Bourne, R.B.1    Rorabeck, C.H.2    Burkart, B.C.3
  • 4
    • 0031765139 scopus 로고    scopus 로고
    • A critical look at cementless stems
    • Bourne RB, Rorabeck CH. A critical look at cementless stems. Clin Orthop 1998;355:212-23.
    • (1998) Clin Orthop , vol.355 , pp. 212-223
    • Bourne, R.B.1    Rorabeck, C.H.2
  • 5
    • 0027495699 scopus 로고
    • Thigh pain in cementless total hip arthroplasty: A comparison of two systems at 2 years' follow-up
    • Burkart BC, Bourne RB, Rorabeck CH, et al. Thigh pain in cementless total hip arthroplasty: a comparison of two systems at 2 years' follow-up. Orthop Clin North Am 1993;24:645-53.
    • (1993) Orthop Clin North Am , vol.24 , pp. 645-653
    • Burkart, B.C.1    Bourne, R.B.2    Rorabeck, C.H.3
  • 6
    • 0015789149 scopus 로고
    • Low-friction arthroplasty in congenital subluxation of the hip
    • Charnley J, Feagin JA. Low-friction arthroplasty in congenital subluxation of the hip. Clin Orthop 1973;91:98-113.
    • (1973) Clin Orthop , vol.91 , pp. 98-113
    • Charnley, J.1    Feagin, J.A.2
  • 7
    • 0026674164 scopus 로고
    • Computerized templating in uncemented total hip arthroplasty to assess component fit and fill
    • Clarke HJ, Jinnah RH, Cox QGN, et al. Computerized templating in uncemented total hip arthroplasty to assess component fit and fill. J Arthroplasty 1992;7:235-9.
    • (1992) J Arthroplasty , vol.7 , pp. 235-239
    • Clarke, H.J.1    Jinnah, R.H.2    Cox, Q.G.N.3
  • 8
    • 0018383689 scopus 로고
    • Total hip replacement in congenital dislocation and dysplasia of the hip
    • Crowe JF, Mani VJ, Ranawat CS. Total hip replacement in congenital dislocation and dysplasia of the hip. J Bone Joint Surg Am 1979;61:15-23.
    • (1979) J Bone Joint Surg Am , vol.61 , pp. 15-23
    • Crowe, J.F.1    Mani, V.J.2    Ranawat, C.S.3
  • 10
    • 0031021439 scopus 로고    scopus 로고
    • Failure mechanisms of anatomic porous replacement I cementless total hip replacement
    • Dorr LD, Lewonowski K, Lucero M, et al. Failure mechanisms of Anatomic Porous Replacement I cementless total hip replacement. Clin Orthop 1997;334:157-67.
    • (1997) Clin Orthop , vol.334 , pp. 157-167
    • Dorr, L.D.1    Lewonowski, K.2    Lucero, M.3
  • 11
    • 0017078724 scopus 로고
    • Total hip reconstruction in chronically dislocated hips
    • Dunn HK, Hess WE. Total hip reconstruction in chronically dislocated hips. J Bone Joint Surg Am 1976;58:838-45.
    • (1976) J Bone Joint Surg Am , vol.58 , pp. 838-845
    • Dunn, H.K.1    Hess, W.E.2
  • 12
    • 0028129576 scopus 로고
    • Effect of rotation on the radiographie appearance of the femoral canal
    • Eckrich SGJ, Noble PC, Tullos HS. Effect of rotation on the radiographie appearance of the femoral canal. J Arthroplasty 1994;9:419-26.
    • (1994) J Arthroplasty , vol.9 , pp. 419-426
    • Eckrich, S.G.J.1    Noble, P.C.2    Tullos, H.S.3
  • 13
    • 0025695691 scopus 로고
    • The case for porous-coated hip implants. The femoral side
    • Engh CA, Classman AH, Suthers KE. The case for porous-coated hip implants. The femoral side. Clin Orthop 1990;261:63-81.
    • (1990) Clin Orthop , vol.261 , pp. 63-81
    • Engh, C.A.1    Classman, A.H.2    Suthers, K.E.3
  • 14
    • 84872239557 scopus 로고    scopus 로고
    • Efficacy of robot-assisted hip stem implantation. A radiographic comparison of matched-pair femurs prepared manually and with the Robodoc system using an anatomic prosthesis
    • Delp SL, DiGioia AM, Jaramaz B, editors, Heidelberg: Springer
    • Gossé F, Wenger KH, Knabe K, et al. Efficacy of robot-assisted hip stem implantation. A radiographic comparison of matched-pair femurs prepared manually and with the Robodoc system using an anatomic prosthesis. In: Delp SL, DiGioia AM, Jaramaz B, editors. Medical image computing and computer-assisted intervention, Heidelberg: Springer 2000; p. 1180-4.
    • (2000) Medical Image Computing and Computer-Assisted Intervention , pp. 1180-1184
    • Gossé, F.1    Wenger, K.H.2    Knabe, K.3
  • 15
    • 0025642527 scopus 로고
    • The various stress patterns of press-fit, ingrown, and cemented femoral stems
    • Huiskes R. The various stress patterns of press-fit, ingrown, and cemented femoral stems. Clin Orthop 1990;261:27-38.
    • (1990) Clin Orthop , vol.261 , pp. 27-38
    • Huiskes, R.1
  • 16
    • 0029591994 scopus 로고
    • Total hip arthroplasty using the Zweymuller stem implanted without cement
    • Huo MH, Martin RP, Zatorski LE, et al. Total hip arthroplasty using the Zweymuller stem implanted without cement. J Arthroplasty 1995;10:793-9.
    • (1995) J Arthroplasty , vol.10 , pp. 793-799
    • Huo, M.H.1    Martin, R.P.2    Zatorski, L.E.3
  • 17
    • 85030825842 scopus 로고    scopus 로고
    • Is there a difference between the planning and the real position of the shaft 300 days after a robot assisted total hip replacement?
    • Lemke HU, Vannier MW, Inamura K, et al., editors; 1998 June 24-7; Tokyo. Amsterdam: Elsevier
    • Lahmer A, Bauer A, Hollmann G, et al. Is there a difference between the planning and the real position of the shaft 300 days after a robot assisted total hip replacement? In: Lemke HU, Vannier MW, Inamura K, et al., editors. Computer assisted radiology and surgery: proceedings of the 12th International Symposium and Exhibition (CAR'98); 1998 June 24-7; Tokyo. Amsterdam: Elsevier; 1998. p. 694-8.
    • (1998) Computer Assisted Radiology and Surgery: Proceedings of the 12th International Symposium and Exhibition (CAR'98) , pp. 694-698
    • Lahmer, A.1    Bauer, A.2    Hollmann, G.3
  • 18
    • 0026583171 scopus 로고
    • Total hip replacement in the 1990s: The procedure, the patient, the surgeon
    • Mallory TH. Total hip replacement in the 1990s: the procedure, the patient, the surgeon. Orthopedics 1992;15:427-30.
    • (1992) Orthopedics , vol.15 , pp. 427-430
    • Mallory, T.H.1
  • 19
    • 0029796988 scopus 로고    scopus 로고
    • Clinical and radiographie outcome of a cementless, titanium, plasma-spray coated total hip arthroplasty femoral component. Justification for continuance of use
    • Mallory TH, Head WC, Lombardi Jr AV, et al. Clinical and radiographie outcome of a cementless, titanium, plasma-spray coated total hip arthroplasty femoral component. Justification for continuance of use. J Arthroplasty 1996;11:653-60.
    • (1996) J Arthroplasty , vol.11 , pp. 653-660
    • Mallory, T.H.1    Head, W.C.2    Lombardi Jr., A.V.3
  • 20
    • 77049159486 scopus 로고
    • Functional results of hip arthroplasty with acrylic prosthesis
    • Merle d'Aubigné R, Postel M. Functional results of hip arthroplasty with acrylic prosthesis. J Bone Joint Surg Am 1954; 36:451-75.
    • (1954) J Bone Joint Surg Am , vol.36 , pp. 451-475
    • Merle D'Aubigné, R.1    Postel, M.2
  • 21
    • 0029842374 scopus 로고    scopus 로고
    • A tapered titanium femoral stem inserted without cement in a total hip arthroplasty
    • Mulliken BD, Bourne RB, Rorabeck CH, et al. A tapered titanium femoral stem inserted without cement in a total hip arthroplasty. J Bone Joint Surg Am 1996;78:1214-25.
    • (1996) J Bone Joint Surg Am , vol.78 , pp. 1214-1225
    • Mulliken, B.D.1    Bourne, R.B.2    Rorabeck, C.H.3
  • 22
    • 0038120878 scopus 로고    scopus 로고
    • Comparison of the fit and fill between the Anatomic Hip femoral component and the VerSys taper femoral component using virtual implantation on the ORTHODOC workstation
    • Nishihara S, Sugano N, Nishii T, et al. Comparison of the fit and fill between the Anatomic Hip femoral component and the VerSys taper femoral component using virtual implantation on the ORTHODOC workstation. J Orthop Sci 2003;8:352-60.
    • (2003) J Orthop Sci , vol.8 , pp. 352-360
    • Nishihara, S.1    Sugano, N.2    Nishii, T.3
  • 23
    • 6944241951 scopus 로고    scopus 로고
    • The morphology of the Japanese femur: Computerized reconstruction of 255 dysplastic and normal cases
    • Noble PC, Kamaric E, Sugano N, et al. The morphology of the Japanese femur: computerized reconstruction of 255 dysplastic and normal cases. J Jpn Orthop Assoc 2001;75:228.
    • (2001) J Jpn Orthop Assoc , vol.75 , pp. 228
    • Noble, P.C.1    Kamaric, E.2    Sugano, N.3
  • 24
    • 0034767618 scopus 로고    scopus 로고
    • Knee pain caused by a fiducial marker in the medial femoral condyle
    • Nogler M, Mauer H, Wimmer C, et al. Knee pain caused by a fiducial marker in the medial femoral condyle. Acta Orthop Scand 2001;72:477-80.
    • (2001) Acta Orthop Scand , vol.72 , pp. 477-480
    • Nogler, M.1    Mauer, H.2    Wimmer, C.3
  • 25
    • 0027279793 scopus 로고
    • The effect of axial and torsional loading on strain distribution in the proximal femur as related to cementless total hip arthroplasty
    • Otani T, Whiteside LA, White SE. The effect of axial and torsional loading on strain distribution in the proximal femur as related to cementless total hip arthroplasty. Clin Orthop 1993;292:376-83.
    • (1993) Clin Orthop , vol.292 , pp. 376-383
    • Otani, T.1    Whiteside, L.A.2    White, S.E.3
  • 26
    • 0026471929 scopus 로고
    • Development of a surgical robot for cementless total hip arthroplasty
    • Paul HA, Bargar WL, Mittlestadt B, et al. Development of a surgical robot for cementless total hip arthroplasty. Clin Orthop 1992;285:57-66.
    • (1992) Clin Orthop , vol.285 , pp. 57-66
    • Paul, H.A.1    Bargar, W.L.2    Mittlestadt, B.3
  • 27
    • 0026452590 scopus 로고
    • A knowledge-based computer-aided and manufacturing system for total hip replacement
    • Reuben JD, Chang C, Akin JE, et al. A knowledge-based computer-aided and manufacturing system for total hip replacement. Clin Orthop 1992;285:48-56.
    • (1992) Clin Orthop , vol.285 , pp. 48-56
    • Reuben, J.D.1    Chang, C.2    Akin, J.E.3
  • 28
    • 0031828510 scopus 로고    scopus 로고
    • The morphology of the femur in developmental dysplasia of the hip
    • Sugano N, Noble PC, Kamaric E, et al. The morphology of the femur in developmental dysplasia of the hip. J Bone Joint Surg Br 1998;80:711-9.
    • (1998) J Bone Joint Surg Br , vol.80 , pp. 711-719
    • Sugano, N.1    Noble, P.C.2    Kamaric, E.3
  • 29
    • 0020523578 scopus 로고
    • Complex total hip replacement for dysplastic or hypoplastic hips using miniature or microminiature components
    • Woolson ST, Harris WH. Complex total hip replacement for dysplastic or hypoplastic hips using miniature or microminiature components. J Bone Joint Surg Am 1983;65:1099-108.
    • (1983) J Bone Joint Surg Am , vol.65 , pp. 1099-1108
    • Woolson, S.T.1    Harris, W.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.