메뉴 건너뛰기




Volumn 37, Issue 8 SPEC. ISS. PART 1, 2009, Pages 1438-1445

Relationship between the voltage distribution ratio and the post arc current in double-break vacuum circuit breakers

Author keywords

Double break vacuum circuit breakers; Grading capacitors; Post arc current; Vacuum interrupters

Indexed keywords

AXIAL MAGNETIC FIELD; CIRCUIT BREAKER; DOUBLE BREAK; DOUBLE-BREAK VACUUM CIRCUIT BREAKERS; GRADING CAPACITORS; POST ARC CURRENT; SPIRAL CONTACTS; VACUUM CIRCUIT BREAKER; VACUUM INTERRUPTERS; VOLTAGE DISTRIBUTION RATIO;

EID: 69249223471     PISSN: 00933813     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPS.2009.2015883     Document Type: Conference Paper
Times cited : (74)

References (16)
  • 1
    • 0036394576 scopus 로고    scopus 로고
    • Investigation of dielectric breakdown probability distribution for double-break vacuum circuit breaker
    • Xi'an, China
    • T. Shioiri, Y. Niwa, T. Kamikawaji, and M. Homma, "Investigation of dielectric breakdown probability distribution for double-break vacuum circuit breaker," in Proc. 20th Int. Symp. Discharges Elect. Insul. Vac., Xi'an, China, 2002, pp. 323-326.
    • (2002) Proc. 20th Int. Symp. Discharges Elect. Insul. Vac , pp. 323-326
    • Shioiri, T.1    Niwa, Y.2    Kamikawaji, T.3    Homma, M.4
  • 3
    • 0141884998 scopus 로고    scopus 로고
    • Influence of grading capacitors on the breaking performance of a 24-kV vacuum breaker series design
    • Aug
    • T. Fugel and D. Konig, "Influence of grading capacitors on the breaking performance of a 24-kV vacuum breaker series design," IEEE Trans. Dielectr. Electr. Insul., vol. 10, no. 4, pp. 569-575, Aug. 2003.
    • (2003) IEEE Trans. Dielectr. Electr. Insul , vol.10 , Issue.4 , pp. 569-575
    • Fugel, T.1    Konig, D.2
  • 4
    • 0026138501 scopus 로고
    • Post arc currents in medium voltage interrupting devices
    • Apr
    • A. Girard, G. Bernard, and P. Malkin, "Post arc currents in medium voltage interrupting devices," IEEE Trans. Power Del., vol. 6, no. 2, pp. 849-857, Apr. 1991.
    • (1991) IEEE Trans. Power Del , vol.6 , Issue.2 , pp. 849-857
    • Girard, A.1    Bernard, G.2    Malkin, P.3
  • 5
    • 0024087922 scopus 로고
    • Post arc current of vacuum interrupter after large current interruption
    • Oct
    • Y. Hakamata, Y. Kurosawa, K. Natsui, K. Hirasawa, and K. Kurita, "Post arc current of vacuum interrupter after large current interruption," IEEE Trans. Power Del., vol. 3, no. 4, pp. 1692-1697, Oct. 1988.
    • (1988) IEEE Trans. Power Del , vol.3 , Issue.4 , pp. 1692-1697
    • Hakamata, Y.1    Kurosawa, Y.2    Natsui, K.3    Hirasawa, K.4    Kurita, K.5
  • 9
    • 34548280825 scopus 로고    scopus 로고
    • Vacuum circuit breaker postarc current modeling based on the theory of Langmuir probes
    • Aug
    • E. van Lanen, R. Smeets, M. Popov, and L. van der Sluis, "Vacuum circuit breaker postarc current modeling based on the theory of Langmuir probes," IEEE Trans. Plasma Sci., vol. 35, no. 4, pp. 925-932, Aug. 2007.
    • (2007) IEEE Trans. Plasma Sci , vol.35 , Issue.4 , pp. 925-932
    • van Lanen, E.1    Smeets, R.2    Popov, M.3    van der Sluis, L.4
  • 10
    • 0033353250 scopus 로고    scopus 로고
    • Influence of interrupted current amplitude on the post-arc current and gap recovery after current zeroexperiment and simulation
    • Aug
    • E. Huber, K. Weltmann, and K. Froehlich, "Influence of interrupted current amplitude on the post-arc current and gap recovery after current zeroexperiment and simulation," IEEE Trans. Plasma Sci., vol. 27, no. 4, pp. 930-937, Aug. 1999.
    • (1999) IEEE Trans. Plasma Sci , vol.27 , Issue.4 , pp. 930-937
    • Huber, E.1    Weltmann, K.2    Froehlich, K.3
  • 11
    • 69249245138 scopus 로고    scopus 로고
    • The current interruption process in vacuum,
    • Ph.D. dissertation, Tech. Univ. Delft, Delft, The Netherlands
    • E. van Lanen, "The current interruption process in vacuum," Ph.D. dissertation, Tech. Univ. Delft, Delft, The Netherlands, 2007.
    • (2007)
    • van Lanen, E.1
  • 12
    • 0019248544 scopus 로고
    • The high current metal vapor arc column between separating electrodes
    • Dec
    • J. Heberlein and J. Gorman, "The high current metal vapor arc column between separating electrodes," IEEE Trans. Plasma Sci., vol. PS-8, no. 4, pp. 283-288, Dec. 1980.
    • (1980) IEEE Trans. Plasma Sci , vol.PS-8 , Issue.4 , pp. 283-288
    • Heberlein, J.1    Gorman, J.2
  • 13
    • 0020244853 scopus 로고
    • A review of arcing phenomena in vacuum and in the transition to atmospheric pressure arcs
    • Dec
    • C. Kimblin, "A review of arcing phenomena in vacuum and in the transition to atmospheric pressure arcs," IEEE Trans. Plasma Sci. vol. 10, no. 4, pp. 322-330, Dec. 1982.
    • (1982) IEEE Trans. Plasma Sci , vol.10 , Issue.4 , pp. 322-330
    • Kimblin, C.1
  • 14
    • 0035485318 scopus 로고    scopus 로고
    • Numerical simulation of the residual charge of vacuum interrupters
    • Oct
    • R. Gilles, K. Weltmann, E. Schade, and M. Claessens, "Numerical simulation of the residual charge of vacuum interrupters," IEEE Trans. Plasma Sci., vol. 29, no. 5, pp. 754-758, Oct. 2001.
    • (2001) IEEE Trans. Plasma Sci , vol.29 , Issue.5 , pp. 754-758
    • Gilles, R.1    Weltmann, K.2    Schade, E.3    Claessens, M.4
  • 16
    • 0032304813 scopus 로고    scopus 로고
    • Influence of interrupted current amplitude on the residual current and gap recovery after current zero
    • Eindhoven, The Netherlands
    • E. Huber and K. Frohlich, "Influence of interrupted current amplitude on the residual current and gap recovery after current zero," in Proc. 18th Int. Symp. Discharges Elect. Insul. Vac., Eindhoven, The Netherlands, 1998, vol. 2, pp. 476-79.
    • (1998) Proc. 18th Int. Symp. Discharges Elect. Insul. Vac , vol.2 , pp. 476-479
    • Huber, E.1    Frohlich, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.