메뉴 건너뛰기




Volumn 11, Issue 2, 2009, Pages 253-260

Blood perfusion of the contralateral testis evaluated with contrast-enhanced ultrasound in rabbits with unilateral testicular torsion

Author keywords

[No Author keywords available]

Indexed keywords

SONOVUE; CONTRAST MEDIUM; DIAGNOSTIC AGENT;

EID: 69249214278     PISSN: 1008682X     EISSN: 17457262     Source Type: Journal    
DOI: 10.1038/aja.2008.13     Document Type: Article
Times cited : (16)

References (20)
  • 1
    • 0035029481 scopus 로고    scopus 로고
    • Glucocorticoid hormone can suppress apoptosis of rat testicular germ cells induced by testicular ischemia
    • Yazawa H, Sasagawa I, Suzuki Y, Nakada T. Glucocorticoid hormone can suppress apoptosis of rat testicular germ cells induced by testicular ischemia. Fertil Steril 2001; 75: 980-5.
    • (2001) Fertil Steril , vol.75 , pp. 980-985
    • Yazawa, H.1    Sasagawa, I.2    Suzuki, Y.3    Nakada, T.4
  • 2
    • 0032427011 scopus 로고    scopus 로고
    • Division of the genitofemoral nerve and late orchiectomy: Effects on the contralateral testis in ipsilateral testicular torsion
    • Tander B, Sarica K, Baskin D, Abbasoglu L, Sakiz D, et al. Division of the genitofemoral nerve and late orchiectomy: Effects on the contralateral testis in ipsilateral testicular torsion. Pediatr Surg Int 1998; 14: 14-6.
    • (1998) Pediatr Surg Int , vol.14 , pp. 14-16
    • Tander, B.1    Sarica, K.2    Baskin, D.3    Abbasoglu, L.4    Sakiz, D.5
  • 3
    • 0034126003 scopus 로고    scopus 로고
    • The protective effects of nitric oxide on the contralateral testis in prepubertal rats with unilateral testicular torsion
    • Dokucu AI, Ozturk H, Ozdemir E, Ketani A, Buyukbayram H, et al. The protective effects of nitric oxide on the contralateral testis in prepubertal rats with unilateral testicular torsion. BJU Int 2000; 85: 767-71.
    • (2000) BJU Int , vol.85 , pp. 767-771
    • Dokucu, A.I.1    Ozturk, H.2    Ozdemir, E.3    Ketani, A.4    Buyukbayram, H.5
  • 4
    • 0031801708 scopus 로고    scopus 로고
    • Hemodynamic monitoring of the contralateral testis during unilateral testicular torsion describes the mechanism of damage
    • Salman AB, Mutlu S, Iskit AB, Guc MO, Mutlu M, et al. Hemodynamic monitoring of the contralateral testis during unilateral testicular torsion describes the mechanism of damage. Eur Urol 1998; 33: 576-80.
    • (1998) Eur Urol , vol.33 , pp. 576-580
    • Salman, A.B.1    Mutlu, S.2    Iskit, A.B.3    Guc, M.O.4    Mutlu, M.5
  • 5
    • 0034892626 scopus 로고    scopus 로고
    • Essential role of neutrophils in germ cell-specific apoptosis following ischemia/reperfusion injury of the mouse testis
    • Lysiak JJ, Turner SD, Nguyen QA, Singbartl K, Ley K, et al. Essential role of neutrophils in germ cell-specific apoptosis following ischemia/reperfusion injury of the mouse testis. Biol Reprod 2001; 65: 718-25.
    • (2001) Biol Reprod , vol.65 , pp. 718-725
    • Lysiak, J.J.1    Turner, S.D.2    Nguyen, Q.A.3    Singbartl, K.4    Ley, K.5
  • 6
    • 0034524283 scopus 로고    scopus 로고
    • Effects of unilateral testicular torsion on the blood flow of contralateral testis - an experimental study on dogs
    • Tarhan F, Erbay ME, Erdogan E, Ozgül A, Kuyumcuoglu U. Effects of unilateral testicular torsion on the blood flow of contralateral testis - an experimental study on dogs. Scand J Urol Nephrol 2000; 34: 229-32.
    • (2000) Scand J Urol Nephrol , vol.34 , pp. 229-232
    • Tarhan, F.1    Erbay, M.E.2    Erdogan, E.3    Ozgül, A.4    Kuyumcuoglu, U.5
  • 8
    • 0032322272 scopus 로고    scopus 로고
    • Increased apoptosis in the contralateral testes of patients with testicular torsion as a factor for infertility
    • Hadziselimovic F, Geneto R, Emmons L. Increased apoptosis in the contralateral testes of patients with testicular torsion as a factor for infertility. J Urol 1998; 160: 1158-60.
    • (1998) J Urol , vol.160 , pp. 1158-1160
    • Hadziselimovic, F.1    Geneto, R.2    Emmons, L.3
  • 10
    • 0035995891 scopus 로고    scopus 로고
    • Ischemia, whether from libation or torsion, causes ultrastructural changes on the contralateral testis
    • Savas C, Ozogul C, Karaoz E, Bezir M. Ischemia, whether from libation or torsion, causes ultrastructural changes on the contralateral testis. Scand J Urol Nephrol 2002; 36: 302-6.
    • (2002) Scand J Urol Nephrol , vol.36 , pp. 302-306
    • Savas, C.1    Ozogul, C.2    Karaoz, E.3    Bezir, M.4
  • 11
    • 33747624741 scopus 로고    scopus 로고
    • Immunohistopathology of the contralateral testis of rats undergoing experimental torsion of the spermatic cord
    • Rodriguez MG, Rival C, Theas MS, Lustig L. Immunohistopathology of the contralateral testis of rats undergoing experimental torsion of the spermatic cord. Asian J Androl 2006; 8: 576-83.
    • (2006) Asian J Androl , vol.8 , pp. 576-583
    • Rodriguez, M.G.1    Rival, C.2    Theas, M.S.3    Lustig, L.4
  • 12
    • 0026772077 scopus 로고
    • Contralateral testicular blood flow in unilateral testicular torsion measured by the 133Xe clearance technique
    • Melikoglu M, Guntekin E, Erkilic M, Karaveli S. Contralateral testicular blood flow in unilateral testicular torsion measured by the 133Xe clearance technique. Br J Urol 1992; 69: 633-5.
    • (1992) Br J Urol , vol.69 , pp. 633-635
    • Melikoglu, M.1    Guntekin, E.2    Erkilic, M.3    Karaveli, S.4
  • 13
    • 0024602199 scopus 로고
    • Contralateral testicular blood flow during unilateral testicular torsion
    • Tanyel FC, Büyükpamukçu N, Hiçsönmez A. Contralateral testicular blood flow during unilateral testicular torsion. Br J Urol 1989; 63: 522-4.
    • (1989) Br J Urol , vol.63 , pp. 522-524
    • Tanyel, F.C.1    Büyükpamukçu, N.2    Hiçsönmez, A.3
  • 14
    • 33744801112 scopus 로고    scopus 로고
    • Pulse-inversion US imaging of testicular ischemia: Quantitative and qualitative analyses in a rabbit model
    • Paltiel HJ, Kalish LA, Susaeta RA, Frauscher F, O'Kane PL, et al. Pulse-inversion US imaging of testicular ischemia: Quantitative and qualitative analyses in a rabbit model. Radiology 2006; 239: 718-29.
    • (2006) Radiology , vol.239 , pp. 718-729
    • Paltiel, H.J.1    Kalish, L.A.2    Susaeta, R.A.3    Frauscher, F.4    O'Kane, P.L.5
  • 15
    • 0035661673 scopus 로고    scopus 로고
    • Peptidergic innervation of blood vessels and interstitial cells in the testis of the cat
    • Suburo AM, Chiocchio SR, Soler MV, Nieponice A, Tramezzani JH. Peptidergic innervation of blood vessels and interstitial cells in the testis of the cat. J Androl 2002; 23: 121-34.
    • (2002) J Androl , vol.23 , pp. 121-134
    • Suburo, A.M.1    Chiocchio, S.R.2    Soler, M.V.3    Nieponice, A.4    Tramezzani, J.H.5
  • 16
    • 4544284203 scopus 로고    scopus 로고
    • Ultrasonography of the spermatic cord in children with testicular torsion: Impact on the surgical strategy
    • Kalfa N, Veyrac C, Baud C, Couture A, Averous M, et al. Ultrasonography of the spermatic cord in children with testicular torsion: Impact on the surgical strategy. J Urol 2004; 172: 1692-5.
    • (2004) J Urol , vol.172 , pp. 1692-1695
    • Kalfa, N.1    Veyrac, C.2    Baud, C.3    Couture, A.4    Averous, M.5
  • 18
    • 0036340309 scopus 로고    scopus 로고
    • Ultrasound imaging with Sonovue: Low mechanical index real-time imaging
    • Bauer A, Solbiati L, Wessman N. Ultrasound imaging with Sonovue: Low mechanical index real-time imaging. Acad Radiol 2002; 9(Suppl): 282-4.
    • (2002) Acad Radiol , vol.9 , Issue.SUPPL. , pp. 282-284
    • Bauer, A.1    Solbiati, L.2    Wessman, N.3
  • 19
    • 0027496845 scopus 로고
    • Second harmonic ultrasound blood perfusion measurement
    • Schrope BA, Newhouse VL. Second harmonic ultrasound blood perfusion measurement. Ultrasound Med Biol 1993; 19: 567-79.
    • (1993) Ultrasound Med Biol , vol.19 , pp. 567-579
    • Schrope, B.A.1    Newhouse, V.L.2
  • 20
    • 0035180412 scopus 로고    scopus 로고
    • Accuracy and reproducibility of coronary flow rate assessment by real-time contrast echocardiography: In vitro and in vivo studies
    • Lafitte S, Masugata H, Peters B, Togni M, Strachan M, et al. Accuracy and reproducibility of coronary flow rate assessment by real-time contrast echocardiography: in vitro and in vivo studies. J Am Soc Echocardiogr 2001; 14: 1010-9.
    • (2001) J Am Soc Echocardiogr , vol.14 , pp. 1010-1019
    • Lafitte, S.1    Masugata, H.2    Peters, B.3    Togni, M.4    Strachan, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.