메뉴 건너뛰기




Volumn 21, Issue 6, 2009, Pages 295-299

Cutting balloon angioplasty for aortic coarctation

Author keywords

[No Author keywords available]

Indexed keywords

AORTA COARCTATION; ARM BLOOD FLOW; ARTERIOVENOUS FISTULA; ARTICLE; BALLOON DILATATION; BODY WEIGHT; CHILD; CLINICAL ARTICLE; COHORT ANALYSIS; CUTTING BALLOON ANGIOPLASTY; FALSE ANEURYSM; FEMALE; FEMORAL ARTERY; FEMORAL VEIN; FOLLOW UP; HUMAN; INFANT; LEG BLOOD FLOW; MALE; OUTCOME ASSESSMENT; PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY; PRESCHOOL CHILD; PRESSURE GRADIENT; RETROSPECTIVE STUDY; RISK ASSESSMENT; SYSTOLIC BLOOD PRESSURE; VASCULAR LESION;

EID: 69249138228     PISSN: 10423931     EISSN: 15572501     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (7)

References (17)
  • 1
    • 0020025484 scopus 로고
    • Balloon dilatation of excised aortic coarctations
    • Lock JE, Castaneda-Zuniga WR, Bass JL, et al. Balloon dilatation of excised aortic coarctations. Radiology 1982;143:689-691.
    • (1982) Radiology , vol.143 , pp. 689-691
    • Lock, J.E.1    Castaneda-Zuniga, W.R.2    Bass, J.L.3
  • 2
    • 0021090864 scopus 로고
    • Treatment of restenosis of coarctation by percutaneous transluminal angioplasty
    • Kan JS, White RI Jr, Mitchell SE, et al. Treatment of restenosis of coarctation by percutaneous transluminal angioplasty. Circulation 1983;68:1087-1094. (Pubitemid 14238487)
    • (1983) Circulation , vol.68 , Issue.5 , pp. 1087-1094
    • Kan, J.S.1    White Jr., R.I.2    Mitchell, S.E.3
  • 3
    • 0023279013 scopus 로고
    • Balloon dilation angioplasty of postoperative aortic obstructions
    • DOI 10.1016/0002-9149(87)91130-1
    • Saul JP, Keane JF, Fellows KE, Lock JE. Balloon dilatation angioplasty of postoperative aortic obstructions. Am J Cardiol 1987;59:943-948. (Pubitemid 17074239)
    • (1987) American Journal of Cardiology , vol.59 , Issue.9 , pp. 943-948
    • Saul, J.P.1    Keane, J.F.2    Fellows, K.E.3    Lock, J.E.4
  • 4
    • 0027619144 scopus 로고
    • Balloon-expandable stent treatment of experimental coarctation of the aorta: Early hemodynamic and pathological evaluation
    • Beekman RH, Muller DW, Reynolds PI, et al. Balloon-expandable stent treatment of experimental coarctation of the aorta: Early hemodynamic and pathological evaluation. J Interv Cardiol 1993;6:113-123.
    • (1993) J Interv Cardiol , vol.6 , pp. 113-123
    • Beekman, R.H.1    Muller, D.W.2    Reynolds, P.I.3
  • 5
    • 0031539286 scopus 로고    scopus 로고
    • Use of balloon-expandable stents for coarctation of the aorta: Initial results and intermediate-term follow-up
    • Ebeid MR, Prieto LR, Latson LA. Use of balloon-expandable stents for coarctation of the aorta: Initial results and intermediate-term follow-up. J Am Coll Cardiol 1997;30:1847-1852.
    • (1997) J Am Coll Cardiol , vol.30 , pp. 1847-1852
    • Ebeid, M.R.1    Prieto, L.R.2    Latson, L.A.3
  • 7
    • 0037299631 scopus 로고    scopus 로고
    • Effect of cutting balloon angioplasty on resistant pulmonary artery stenosis
    • DOI 10.1016/S0002-9149(02)03107-7, PII S0002914902031077
    • Bergersen LJ, Perry SB, Lock JE. Effect of cutting balloon angioplasty on resistant pulmonary artery stenosis. Am J Cardiol 2003;91:185-189. (Pubitemid 36084304)
    • (2003) American Journal of Cardiology , vol.91 , Issue.2 , pp. 185-189
    • Bergersen, L.J.1    Perry, S.B.2    Lock, J.E.3
  • 9
    • 33645073698 scopus 로고    scopus 로고
    • Comparison of efficacy of medium-sized cutting balloons versus standard balloons for dilatation of peripheral pulmonary stenosis
    • Suda K, Matsumura M, Hayashi H, Nishimura K. Comparison of efficacy of medium-sized cutting balloons versus standard balloons for dilatation of peripheral pulmonary stenosis. Am J Cardiol 2006;97:1060-1063.
    • (2006) Am J Cardiol , vol.97 , pp. 1060-1063
    • Suda, K.1    Matsumura, M.2    Hayashi, H.3    Nishimura, K.4
  • 10
    • 0026049106 scopus 로고
    • Cutting balloon: A novel approach to percutaneous angioplasty
    • Barath P, Fishbein MC, Vari S, Forrester JS. Cutting balloon: A novel approach to percutaneous angioplasty. Am J Cardiol 1991;68:1249-1252.
    • (1991) Am J Cardiol , vol.68 , pp. 1249-1252
    • Barath, P.1    Fishbein, M.C.2    Vari, S.3    Forrester, J.S.4
  • 12
    • 0042266856 scopus 로고    scopus 로고
    • Multivessel cutting balloon angioplasty in a patient with type III nonspecific aortoarteritis
    • Joseph G, Pati PK, Mathews P. Multivessel cutting balloon angioplasty in a patient with type III nonspecific aortoarteritis. Indian Heart J 2003;55:175-177. (Pubitemid 36917229)
    • (2003) Indian Heart Journal , vol.55 , Issue.2 , pp. 175-177
    • Joseph, G.1    Pati, P.K.2    Mathews, P.3
  • 13
    • 0037382013 scopus 로고    scopus 로고
    • Cutting balloon angioplasty for undilatable venous stenoses causing dialysis graft failure
    • Bittl JA, Feldman RL. Cutting balloon angioplasty for undilatable venous stenoses causing dialysis graft failure. Catheter Cardiovasc Interv 2003;58:524-526.
    • (2003) Catheter Cardiovasc Interv , vol.58 , pp. 524-526
    • Bittl, J.A.1    Feldman, R.L.2
  • 14
    • 0035465435 scopus 로고    scopus 로고
    • Use of a cutting balloon catheter to dilate resistant stenoses in major aortic-to-pulmonary collateral arteries
    • Mertens L, Dens J, Gewillig M. Use of a cutting balloon catheter to dilate resistant stenoses in major aortic-to-pulmonary collateral arteries. Cardiol Young 2001;11:574-577. (Pubitemid 33735196)
    • (2001) Cardiology in the Young , vol.11 , Issue.5 , pp. 574-577
    • Mertens, L.1    Dens, J.2    Gewillig, M.3
  • 15
    • 14444275200 scopus 로고    scopus 로고
    • Microsurgical dilatation concept: Animal data
    • Barath P. Microsurgical dilatation concept: Animal data. J Invasive Cardiol 1996;8(Suppl A):2A-5A. (Pubitemid 126736401)
    • (1996) Journal of Invasive Cardiology , vol.8 , Issue.SUPPL. A
    • Barath, P.1
  • 16
    • 0032581031 scopus 로고    scopus 로고
    • Lower expression of neutrophil adhesion molecule indicates less vessel wall injury and might explain lower restenosis rate after cutting balloon angioplasty
    • Inoue T, Sakai Y, Hoshi K, et al. Lower expression of neutrophil adhesion molecule indicates less vessel wall injury and might explain lower restenosis rate after cutting balloon angioplasty. Circulation 1998;97:2511-2518. (Pubitemid 28294497)
    • (1998) Circulation , vol.97 , Issue.25 , pp. 2511-2518
    • Inoue, T.1    Sakai, Y.2    Hoshi, K.3    Yaguchi, I.4    Fujito, T.5    Morooka, S.6
  • 17
    • 0002428149 scopus 로고    scopus 로고
    • Comparison of angiographie and clinical outcome after cutting balloon and conventional balloon angioplasty in vessels smaller than 3 mm in diameter: A randomized trial
    • Ergene O, Seyithanoglu BY, Tastan A, et al. Comparison of angiographic and clinical outcome after cutting balloon and conventional balloon angioplasty in vessels smaller than 3 mm in diameter: A randomized trial. J Invasive Cardiol 1998;10:70-75. (Pubitemid 128708922)
    • (1998) Journal of Invasive Cardiology , vol.10 , Issue.2 , pp. 70-75
    • Ergene, O.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.