메뉴 건너뛰기




Volumn 28, Issue 4, 2009, Pages 397-405

Thrombus size and doppler embolic signal intensity

Author keywords

Carotid endarterectomy; Embolus detection; Micro embolic signals; Thrombus formation; Transcranial Doppler ultrasound

Indexed keywords

ARTICLE; CAROTID ARTERY SURGERY; CAROTID ARTERY THROMBOSIS; CORRELATION COEFFICIENT; DOPPLER ECHOGRAPHY; EMBOLISM; ERYTHROCYTE AGGREGATION; IN VITRO STUDY; MICROSCOPY; OSCILLATION; PRIORITY JOURNAL; SIGNAL TRANSDUCTION; THROMBUS;

EID: 69149109879     PISSN: 10159770     EISSN: None     Source Type: Journal    
DOI: 10.1159/000235627     Document Type: Article
Times cited : (12)

References (29)
  • 1
    • 33846955080 scopus 로고    scopus 로고
    • Current concepts: Perioperative stroke
    • Selim M: Current concepts: perioperative stroke. N Engl J Med 2007; 356: 706-713
    • (2007) N Engl J Med , vol.356 , pp. 706-713
    • Selim, M.1
  • 2
    • 1842486668 scopus 로고    scopus 로고
    • Beneficial effects of clopidogrel combined with aspirin in reducing cerebral emboli in patients undergoing carotid endarterectomy
    • Payne DA, Jones CI, Hayes PD, Thompson MM, London NJ, Bell PR, Goodall AH, Naylor AR: Beneficial effects of clopidogrel combined with aspirin in reducing cerebral emboli in patients undergoing carotid endarterectomy. Circulation 2004;109: 1476-1481
    • (2004) Circulation , vol.109 , pp. 1476-1481
    • Payne, D.A.1    Jones, C.I.2    Hayes, P.D.3    Thompson, M.M.4    London, N.J.5    Bell, P.R.6    Goodall, A.H.7    Naylor, A.R.8
  • 3
    • 36348998071 scopus 로고    scopus 로고
    • Prevention of perioperative thromboembolism in patients with atrial fibrillation
    • Beldi G, Beng L, Siegel G, Bisch-Knaden S, Candinas D: Prevention of perioperative thromboembolism in patients with atrial fibrillation. Br J Surg 2007; 94: 1351-1355
    • (2007) Br J Surg , vol.94 , pp. 1351-1355
    • Beldi, G.1    Beng, L.2    Siegel, G.3    Bisch-Knaden, S.4    Candinas, D.5
  • 4
    • 70349339427 scopus 로고    scopus 로고
    • Detection of microemboli; in Babikian VL, Wechsler LR (eds): Transcranial Doppler Ultrasonography, ed 2
    • Evans DH: Detection of microemboli; in Babikian VL, Wechsler LR (eds): Transcranial Doppler Ultrasonography, ed 2. Boston, Butterworth Heinemann, 1999, pp 141-155
    • (1999) Boston, Butterworth Heinemann , pp. 141-155
    • Evans, D.H.1
  • 5
    • 33745590653 scopus 로고    scopus 로고
    • Characteristics of Doppler embolic signals observed following carotid endarterectomy
    • Chung EML, Fan L, Naylor AR, Evans DH: Characteristics of Doppler embolic signals observed following carotid endarterectomy. Ultrasound Med Biol 2006; 32: 1011-1023
    • (2006) Ultrasound Med Biol , vol.32 , pp. 1011-1023
    • Chung, E.M.L.1    Fan, L.2    Naylor, A.R.3    Evans, D.H.4
  • 6
    • 33846937048 scopus 로고    scopus 로고
    • Impact of clinical environment on embolus detection: A comparison of automated and manual detection of embolic signals
    • Chung EML, Fan L, Naylor AR, Evans DH: Impact of clinical environment on embolus detection: A comparison of automated and manual detection of embolic signals. Cerebrovasc Dis 2007; 23: 169-174
    • (2007) Cerebrovasc Dis , vol.23 , pp. 169-174
    • Chung, E.M.L.1    Fan, L.2    Naylor, A.R.3    Evans, D.H.4
  • 7
    • 0015360662 scopus 로고
    • Ultrasonic detection of bubbles with Doppler flow transducers
    • Nishi RY: Ultrasonic detection of bubbles with Doppler flow transducers. Ultrasonics 1972; 10: 173-179
    • (1972) Ultrasonics , vol.10 , pp. 173-179
    • Nishi, R.Y.1
  • 8
    • 0017341377 scopus 로고
    • An ultrasonic detector for microgas emboli in a bloodflow line
    • Lubbers J, Van den Berg JW: An ultrasonic detector for microgas emboli in a bloodflow line. Ultrasound Med Biol 1977; 2: 301-310
    • (1977) Ultrasound Med Biol , vol.2 , pp. 301-310
    • Lubbers, J.1    Van Den Berg, J.W.2
  • 9
    • 0028329071 scopus 로고
    • Pulse Doppler ultrasound detection, characterization and size estimation of emboli in flowing blood
    • Moehring MA, Klepper JR: Pulse Doppler ultrasound detection, characterization and size estimation of emboli in flowing blood. IEEE Trans Biomed Eng 1994; 41: 35-44
    • (1994) IEEE Trans Biomed Eng , vol.41 , pp. 35-44
    • Moehring, M.A.1    Klepper, J.R.2
  • 11
    • 10144232394 scopus 로고
    • The intensity of the Doppler signal caused by arterial emboli depends on embolus size
    • Oka M, von Teutern GM, Furuhata H, Kodaira K (eds). Amsterdam, Elsevier Science Publishing
    • Russell D, Brucher R, Madden K, Clark WM, Sandset PM, Zivin J: The intensity of the Doppler signal caused by arterial emboli depends on embolus size; in Oka M, von Teutern GM, Furuhata H, Kodaira K (eds): Recent Advances in Neurosonology. Amsterdam, Elsevier Science Publishing, 1992, pp 57-60
    • (1992) Recent Advances in Neurosonology , pp. 57-60
    • Russell, D.1    Brucher, R.2    Madden, K.3    Clark, W.M.4    Sandset, P.M.5    Zivin, J.6
  • 12
    • 0027434362 scopus 로고
    • Differentiation between different pathological cerebral embolic materials using transcranial Doppler in an in vitro model
    • Markus HS, Brown MM: Differentiation between different pathological cerebral embolic materials using transcranial Doppler in an in vitro model. Stroke 1993; 24: 1-5
    • (1993) Stroke , vol.24 , pp. 1-5
    • Markus, H.S.1    Brown, M.M.2
  • 13
    • 84961021933 scopus 로고
    • In vitro thrombotic coagulation of the blood: A method for producing a thrombus
    • Chandler AB: In vitro thrombotic coagulation of the blood: A method for producing a thrombus. Lab Invest 1958; 7: 110-114
    • (1958) Lab Invest , vol.7 , pp. 110-114
    • Chandler, A.B.1
  • 14
    • 0344751013 scopus 로고
    • A study of artificial thrombi produced by a modification of Chandler's method
    • Poole JCF: A study of artificial thrombi produced by a modification of Chandler's method. Q J Exp Physiol 1959; 44: 377-384
    • (1959) Q J Exp Physiol , vol.44 , pp. 377-384
    • Poole, J.C.F.1
  • 15
    • 0030942189 scopus 로고    scopus 로고
    • Thrombi formed in the Chandler loop mimic human arterial thrombi in structure and PAI-1 content and distribution
    • Robbie LA, Young SP, Bennett B, Booth NA: Thrombi formed in the Chandler loop mimic human arterial thrombi in structure and PAI-1 content and distribution. Thromb Haemost 1997; 77: 510-515
    • (1997) Thromb Haemost , vol.77 , pp. 510-515
    • Robbie, L.A.1    Young, S.P.2    Bennett, B.3    Booth, N.A.4
  • 18
    • 0032033499 scopus 로고    scopus 로고
    • Validation of a new blood-mimicking fluid for use in Doppler flow test objects
    • Ramnarine KV, Nassiri DK, Hoskins PR, Lubbers J: Validation of a new blood-mimicking fluid for use in Doppler flow test objects. Ultrasound Med Biol 1998; 24: 451-459
    • (1998) Ultrasound Med Biol , vol.24 , pp. 451-459
    • Ramnarine, K.V.1    Nassiri, D.K.2    Hoskins, P.R.3    Lubbers, J.4
  • 20
    • 33845622547 scopus 로고    scopus 로고
    • Multigate transcranial Doppler ultrasound system with real-time embolic signal identification and archival
    • Fan L, Boni E, Tortoli P, Evans DH: Multigate transcranial Doppler ultrasound system with real-time embolic signal identification and archival. IEEE Trans Ultrason Ferroelectr Freq Control 2006; 53: 1853-1861
    • (2006) IEEE Trans Ultrason Ferroelectr Freq Control , vol.53 , pp. 1853-1861
    • Fan, L.1    Boni, E.2    Tortoli, P.3    Evans, D.H.4
  • 21
    • 34848820138 scopus 로고    scopus 로고
    • Performance analyses of two transcranial Doppler systems using an electronic phantom and a flow phantom
    • Fan L, Ramnarine KV, Gittins J, Evans DH: Performance analyses of two transcranial Doppler systems using an electronic phantom and a flow phantom. Ultrasound 2006; 14: 272
    • (2006) Ultrasound , vol.14 , pp. 272
    • Fan, L.1    Ramnarine, K.V.2    Gittins, J.3    Evans, D.H.4
  • 22
    • 0037767501 scopus 로고    scopus 로고
    • Limits of uncertainty in measured values of embolus-to-blood ratio due to Doppler sample volume shape and location
    • Angell EL, Evans DH: Limits of uncertainty in measured values of embolus-to-blood ratio due to Doppler sample volume shape and location. Ultrasound Med Biol 2003; 29: 1037-1044
    • (2003) Ultrasound Med Biol , vol.29 , pp. 1037-1044
    • Angell, E.L.1    Evans, D.H.2
  • 23
    • 13644256046 scopus 로고    scopus 로고
    • Limits of uncertainty in measured values of embolus-to-blood ratios in dual-frequency TCD recordings due to nonidentical sample volume shapes
    • Evans DH, Gittins J: Limits of uncertainty in measured values of embolus-to-blood ratios in dual-frequency TCD recordings due to nonidentical sample volume shapes. Ultrasound Med Biol 2005; 31: 233-242
    • (2005) Ultrasound Med Biol , vol.31 , pp. 233-242
    • Evans, D.H.1    Gittins, J.2
  • 24
    • 0037237319 scopus 로고    scopus 로고
    • Experimental demonstration of noninvasive transskull adaptive focusing based on prior computed tomography scans
    • Aubry JF, Tanter M, Pernot M, Thomas JL, Fink M: Experimental demonstration of noninvasive transskull adaptive focusing based on prior computed tomography scans. J Acoust Soc Am 2003; 113: 84-93
    • (2003) J Acoust Soc Am , vol.113 , pp. 84-93
    • Aubry, J.F.1    Tanter, M.2    Pernot, M.3    Thomas, J.L.4    Fink, M.5
  • 27
    • 0036956649 scopus 로고    scopus 로고
    • Real-time detection of activation patterns in individual platelets during thrombo- embolism in vivo: Differences between thrombus growth and embolus formation
    • Van Gestel MA, Heemskerk JWM, Slaaf DW, et al: Real-time detection of activation patterns in individual platelets during thrombo- embolism in vivo: differences between thrombus growth and embolus formation. J Vasc Res 2002; 39: 534-543
    • (2002) J Vasc Res , vol.39 , pp. 534-543
    • Van Gestel, M.A.1    Heemskerk, J.W.M.2    Slaaf, D.W.3
  • 29
    • 70349307106 scopus 로고    scopus 로고
    • Baker AC, Duck FA, Starritt HC (eds): Ultrasound in Medicine. Boca Raton, CRC Press
    • Baker AC, Duck FA, Starritt HC (eds): Ultrasound in Medicine. Boca Raton, CRC Press, 1998
    • (1998)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.