메뉴 건너뛰기




Volumn 2, Issue , 1999, Pages 930-936

An adaptive fault locator system for transmission lines

Author keywords

Discrete Fourier Transforms (DFT); Fault DetectiodLocation Index; Parameter Estimation Algorithm; Phasor Measurement Unit (PMU)

Indexed keywords

DISCRETE FOURIER TRANSFORMS; ERRORS; GLOBAL POSITIONING SYSTEM; LOCATION; PHASE MEASUREMENT; PHASOR MEASUREMENT UNITS; SYNCHRONIZATION; UNITS OF MEASUREMENT;

EID: 69049096739     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/PESS.1999.787441     Document Type: Conference Paper
Times cited : (13)

References (16)
  • 1
    • 0019548243 scopus 로고
    • A New Alogrithm of an Accurate Fault Location for EHV/UHV Transmission Lines: Part i - Fourier Transformation Method
    • March
    • T. Takagi, Y. Yamakoshi, J. Baba, K. Uemura, and T. Sakaguchi, "A New Alogrithm of an Accurate Fault Location for EHV/UHV Transmission Lines: Part I - Fourier Transformation Method", IEEE Transactions on Power Apparatus and Systems, Vol. PAS-100, No. 3, March 1981, pp.1316-1323.
    • (1981) IEEE Transactions on Power Apparatus and Systems , vol.PAS-100 , Issue.3 , pp. 1316-1323
    • Takagi, T.1    Yamakoshi, Y.2    Baba, J.3    Uemura, K.4    Sakaguchi, T.5
  • 2
    • 0019534863 scopus 로고
    • A New Algorithm of an Accurate Fault Location for EHV/UHV Transmission Lines: Part II - Laplace Transform Method
    • March
    • T. Takagi, Y. Yamakoshi, J. Baba, K. Uemura, and T. Sakaguchi, "A New Algorithm of an Accurate Fault Location for EHV/UHV Transmission Lines: Part II - Laplace Transform Method", IEEE Transactions on Power Apparatus and Systems, Vol. PAS-101, No. 3, March 1982, pp.564-573.
    • (1982) IEEE Transactions on Power Apparatus and Systems , vol.PAS-101 , Issue.3 , pp. 564-573
    • Takagi, T.1    Yamakoshi, Y.2    Baba, J.3    Uemura, K.4    Sakaguchi, T.5
  • 3
    • 0028426833 scopus 로고
    • An Accurate Fault Location Algorithm Using Synchronized Sampling
    • M. Kezunovi, J. Mrki, and B. Perunici, "An Accurate Fault Location Algorithm Using Synchronized Sampling", Electric Power Systems Research, Vol. 29, 1994, pp.161-169.
    • (1994) Electric Power Systems Research , vol.29 , pp. 161-169
    • Kezunovi, M.1    Mrki, J.2    Perunici, B.3
  • 4
    • 0026623757 scopus 로고
    • A New Fault Location Technique for Two- and Three-Terminal Lines
    • January
    • A. A. Girgis, D. G. Hart, and W.L. Peterson, "A New Fault Location Technique For Two- and Three-Terminal Lines", IEEE Transactions on Power Delivery, Vol. 7, No.l, January 1992, pp.98-107.
    • (1992) IEEE Transactions on Power Delivery , vol.7 , Issue.1 , pp. 98-107
    • Girgis, A.A.1    Hart, D.G.2    Peterson, W.L.3
  • 6
    • 0025517399 scopus 로고
    • Accurate Fault Location Technique for Power Transmission Lines
    • November
    • A. T. Johns, and S. Jamali, "Accurate Fault Location Technique For Power Transmission Lines", IEE Proceedings, Vol.137, Pt.C, No. 6, November 1990, pp.395-402.
    • (1990) IEE Proceedings , vol.137 , Issue.6 , pp. 395-402
    • Johns, A.T.1    Jamali, S.2
  • 7
    • 0027635001 scopus 로고
    • A Practical Approach to Accurate Fault Location on Extra High Voltage Teed Feeders
    • July
    • P. K. Aggarwal, D. V. Coury, A. T. Johns, and A. Kalam, "A Practical Approach To Accurate Fault Location on Extra High Voltage Teed Feeders", IEEE Transactions on Power Delivery, Vol. 8, No. 3, July 1992, pp.874-883.
    • (1992) IEEE Transactions on Power Delivery , vol.8 , Issue.3 , pp. 874-883
    • Aggarwal, P.K.1    Coury, D.V.2    Johns, A.T.3    Kalam, A.4
  • 8
    • 0026938291 scopus 로고
    • Development of an Advanced Transmission Line Fault Location System, Part I: Input Transducer Analysis and Requirements
    • October
    • D. J. Lawrence, L. Z. Cabeza, and L. T. Hochberg, "Development of an Advanced Transmission Line Fault Location System, Part I: Input Transducer Analysis and Requirements", IEEE Transactions on Power Delivery, Vol. 7, No. 4, October 1992, pp. 1963-1971.
    • (1992) IEEE Transactions on Power Delivery , vol.7 , Issue.4 , pp. 1963-1971
    • Lawrence, D.J.1    Cabeza, L.Z.2    Hochberg, L.T.3
  • 9
    • 0026939751 scopus 로고
    • Development of An Advanced Transmission Line Fault Location System, Part 11: Algorithm Development and Simulation
    • October
    • D. J. Lawrence, L. Z. Cabeza, and L. T. Hochberg, "Development of An Advanced Transmission Line Fault Location System, Part 11: Algorithm Development and Simulation", IEEE Transactions on Power Delivery, Vol. 7, No. 4, October 1992, pp. 1972-1981.
    • (1992) IEEE Transactions on Power Delivery , vol.7 , Issue.4 , pp. 1972-1981
    • Lawrence, D.J.1    Cabeza, L.Z.2    Hochberg, L.T.3
  • 10
    • 0028368968 scopus 로고
    • An Overview of Digital Fault Location Algorithms for Power Transmission Lines Using Transient Waveforms
    • B. Lian and M. M. A. Salama, "An Overview Of Digital Fault Location Algorithms For Power Transmission Lines Using Transient Waveforms", Electric Power Systems Research, Vol. 29, 1994. pp. 17-25.
    • (1994) Electric Power Systems Research , vol.29 , pp. 17-25
    • Lian, B.1    Salama, M.M.A.2
  • 11
    • 0003521931 scopus 로고    scopus 로고
    • Advancements in Microprocessor Based Protection and Communication
    • Power Engineering Education Committee and the Power System Relaying Committee of the IEEE Power Engineering Society, "Advancements in Microprocessor Based Protection and Communication", IEEE Tutorial Course, 1997, pp. 63-72.
    • (1997) IEEE Tutorial Course , pp. 63-72
  • 14
    • 84947668221 scopus 로고
    • State Estimation with Phasor Measurements
    • February
    • A. G. Phadke, J. S. Thorp, and K. J. Karimi, "State Estimation with Phasor Measurements", IEEE Transactions on Power Systems, Vol. PWRS-1, No. 1, February 1986, pp. 233-241.
    • (1986) IEEE Transactions on Power Systems , vol.PWRS-1 , Issue.1 , pp. 233-241
    • Phadke, A.G.1    Thorp, J.S.2    Karimi, K.J.3
  • 15
    • 0030779301 scopus 로고    scopus 로고
    • Modal Analysis of Untransposed Bilateral Three-Phase Lines - A Perterbation Approach
    • October
    • J. A. Brandao Faria, and J. H. Bricefio Mendez, "Modal Analysis of Untransposed Bilateral Three-Phase Lines - A Perterbation Approach", IEEE Transactions on Power Delivery, Vol.12, No. 1, October, 1997, pp. 497-504.
    • (1997) IEEE Transactions on Power Delivery , vol.12 , Issue.1 , pp. 497-504
    • Brandao Faria, J.A.1    Bricefio Mendez, J.H.2
  • 16
    • 0032674438 scopus 로고    scopus 로고
    • A Smart Method Makes DFT More Precise for Power System Frequency Estimation
    • January
    • J. Z. Yang and C. W. Liu, "A Smart Method Makes DFT More Precise for Power System Frequency Estimation", In IEEE/PES Winter Meeting, January 1999, pp. 909-913.
    • (1999) IEEE/PES Winter Meeting , pp. 909-913
    • Yang, J.Z.1    Liu, C.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.