메뉴 건너뛰기




Volumn 19, Issue 5, 2009, Pages

Test-retest reliability of cardinal plane isokinetic hip torque and EMG

Author keywords

Abduction; Adduction; Electromyography; Extension; Flexion

Indexed keywords

ABDUCTION; ADDUCTION; ADULT; ARTICLE; CONCENTRIC MUSCLE CONTRACTION; CONTROLLED STUDY; DYNAMOMETRY; ECCENTRIC MUSCLE CONTRACTION; ELECTROMYOGRAPHY; FEMALE; GLUTEUS MAXIMUS MUSCLE; HAMSTRING; HIP; HUMAN; HUMAN EXPERIMENT; ISOKINETIC EXERCISE; KINEMATICS; MALE; MEASUREMENT ERROR; MUSCLE FUNCTION; NORMAL HUMAN; PRIORITY JOURNAL; RECTUS FEMORIS MUSCLE; TEST RETEST RELIABILITY; TORQUE;

EID: 68949194274     PISSN: 10506411     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jelekin.2008.07.005     Document Type: Article
Times cited : (44)

References (40)
  • 1
    • 0003410008 scopus 로고    scopus 로고
    • American College of Sports Medicine, Franklin BA, Whaley MH, Howley ET, editors, 6th ed. Baltimore: Lippincott Williams & Wilkins;
    • American College of Sports Medicine. In: Franklin BA, Whaley MH, Howley ET, editors. ACSM's guidelines for exercise testing and prescription. 6th ed. Baltimore: Lippincott Williams & Wilkins; 2000. p. 22-32.
    • (2000) ACSM's guidelines for exercise testing and prescription , pp. 22-32
  • 3
    • 33750976379 scopus 로고    scopus 로고
    • Reliability of electromyographic normalization methods for evaluating the hip musculature
    • Bolgla L.A., and Uhl T.L. Reliability of electromyographic normalization methods for evaluating the hip musculature. Journal of Electromyography and Kinesiology 17 (2007) 102-111
    • (2007) Journal of Electromyography and Kinesiology , vol.17 , pp. 102-111
    • Bolgla, L.A.1    Uhl, T.L.2
  • 5
    • 0030834520 scopus 로고    scopus 로고
    • Concentric and eccentric isokinetic assessment of flexor-extensor torque ratios at the hip, knee, and ankle in a sample population of healthy subjects
    • Calmels P.M., Nellen M., Inge van der Borne B.S., Jourdin P., and Minaire P. Concentric and eccentric isokinetic assessment of flexor-extensor torque ratios at the hip, knee, and ankle in a sample population of healthy subjects. Archives of Physical Medicine and Rehabilitation 78 (1997) 1224-1230
    • (1997) Archives of Physical Medicine and Rehabilitation , vol.78 , pp. 1224-1230
    • Calmels, P.M.1    Nellen, M.2    Inge van der Borne, B.S.3    Jourdin, P.4    Minaire, P.5
  • 7
    • 34249784813 scopus 로고    scopus 로고
    • Quadriceps and hamstring isokinetic strength and electromyographic activity measured at different ranges of motion: a reproducibility study
    • Croisier J.L., Malnati M., Reichard L.B., Peretz C., and Dvir Z. Quadriceps and hamstring isokinetic strength and electromyographic activity measured at different ranges of motion: a reproducibility study. Journal of Electromyography and Kinesiology 17 (2007) 484-492
    • (2007) Journal of Electromyography and Kinesiology , vol.17 , pp. 484-492
    • Croisier, J.L.1    Malnati, M.2    Reichard, L.B.3    Peretz, C.4    Dvir, Z.5
  • 10
    • 0033109455 scopus 로고    scopus 로고
    • Test-retest reliability of isokinetic hip adductor and flexor muscle strength
    • Emery C.A., Maitland M.E., and Meeuwisse W.H. Test-retest reliability of isokinetic hip adductor and flexor muscle strength. Clinical Journal of Sports Medicine 9 2 (1999) 79-85
    • (1999) Clinical Journal of Sports Medicine , vol.9 , Issue.2 , pp. 79-85
    • Emery, C.A.1    Maitland, M.E.2    Meeuwisse, W.H.3
  • 12
    • 0023409497 scopus 로고
    • Relationship between isokinetic strength and sprint times in college-age men
    • Farrar M., and Thorland W. Relationship between isokinetic strength and sprint times in college-age men. Journal of Sports Medicine and Physical Fitness 27 (1987) 368-372
    • (1987) Journal of Sports Medicine and Physical Fitness , vol.27 , pp. 368-372
    • Farrar, M.1    Thorland, W.2
  • 15
    • 10044226285 scopus 로고    scopus 로고
    • An evaluation of differences in hip external rotation strength and range of motion between female dancers and non-dancers
    • Gupta A., Fernihough B., Bailey G., Bombeck P., Clarke A., and Hopper D. An evaluation of differences in hip external rotation strength and range of motion between female dancers and non-dancers. British Journal of Sports Medicine 38 (2004) 778-783
    • (2004) British Journal of Sports Medicine , vol.38 , pp. 778-783
    • Gupta, A.1    Fernihough, B.2    Bailey, G.3    Bombeck, P.4    Clarke, A.5    Hopper, D.6
  • 16
    • 84974767705 scopus 로고
    • The relationship between sprint speed and hip flexion/extension strength in collegiate athletes
    • Guskiewicz K., Lephart S., and Burkholder R. The relationship between sprint speed and hip flexion/extension strength in collegiate athletes. Isokinetics and Exercise Science 3 2 (1993) 111-116
    • (1993) Isokinetics and Exercise Science , vol.3 , Issue.2 , pp. 111-116
    • Guskiewicz, K.1    Lephart, S.2    Burkholder, R.3
  • 17
    • 0023220765 scopus 로고
    • Effect of visual feedback on maximal and submaximal isokinetic test measurements of normal quadriceps and hamstrings
    • Hald R.D., and Bottjen E.J. Effect of visual feedback on maximal and submaximal isokinetic test measurements of normal quadriceps and hamstrings. Journal of Orthopaedic and Sports Physical Therapy 9 (1987) 86-93
    • (1987) Journal of Orthopaedic and Sports Physical Therapy , vol.9 , pp. 86-93
    • Hald, R.D.1    Bottjen, E.J.2
  • 18
    • 0036338684 scopus 로고    scopus 로고
    • Test-retest reliability of isokinetic muscle strength of the lower extremities in patients with stroke
    • Hsu A.L., Tang P.F., and Jan M.H. Test-retest reliability of isokinetic muscle strength of the lower extremities in patients with stroke. Archives of Physical Medicine and Rehabilitation 83 (2002) 1130-1137
    • (2002) Archives of Physical Medicine and Rehabilitation , vol.83 , pp. 1130-1137
    • Hsu, A.L.1    Tang, P.F.2    Jan, M.H.3
  • 19
    • 0034903423 scopus 로고    scopus 로고
    • Hip abduction-adduction strength and one-leg hop tests: test-retest reliability and relationship to function in elite ice hockey players
    • Kea J., Kramer J., Forwell L., and Birmingham T. Hip abduction-adduction strength and one-leg hop tests: test-retest reliability and relationship to function in elite ice hockey players. Journal of Orthopaedic and Sports Physical Therapy 31 8 (2001) 446-455
    • (2001) Journal of Orthopaedic and Sports Physical Therapy , vol.31 , Issue.8 , pp. 446-455
    • Kea, J.1    Kramer, J.2    Forwell, L.3    Birmingham, T.4
  • 20
    • 0030063071 scopus 로고    scopus 로고
    • Resistive eccentric exercise: effects of visual feedback on maximal moment of knee extensors and flexors
    • Kellis E., and Baltzopolous V. Resistive eccentric exercise: effects of visual feedback on maximal moment of knee extensors and flexors. Journal of Orthopaedic and Sports Physical Therapy 23 2 (1996) 120-124
    • (1996) Journal of Orthopaedic and Sports Physical Therapy , vol.23 , Issue.2 , pp. 120-124
    • Kellis, E.1    Baltzopolous, V.2
  • 22
    • 0032322670 scopus 로고    scopus 로고
    • Effect of visual feedback and verbal encouragement on eccentric quadriceps and hamstrings peak torque
    • Kimura E.F., Gulick D.T., and Lukasiewicz W.C. Effect of visual feedback and verbal encouragement on eccentric quadriceps and hamstrings peak torque. Sports Medicine, Training and Rehabilitation 9 1 (1999) 61-70
    • (1999) Sports Medicine, Training and Rehabilitation , vol.9 , Issue.1 , pp. 61-70
    • Kimura, E.F.1    Gulick, D.T.2    Lukasiewicz, W.C.3
  • 23
    • 0037409993 scopus 로고    scopus 로고
    • Test-retest reliability of EMG and peak torque during repetitive maximum concentric knee extensions
    • Larsson B., Karlsson S., Eriksson M., and Gerdle B. Test-retest reliability of EMG and peak torque during repetitive maximum concentric knee extensions. Journal of Electromyography and Kinesiology 13 (2003) 281-287
    • (2003) Journal of Electromyography and Kinesiology , vol.13 , pp. 281-287
    • Larsson, B.1    Karlsson, S.2    Eriksson, M.3    Gerdle, B.4
  • 24
    • 0020563311 scopus 로고
    • Myoelectric signal versus force relationship in different human muscles
    • Lawrence J.H., and DeLuca C.J. Myoelectric signal versus force relationship in different human muscles. Journal of Applied Physiology 54 (1983) 1653-1659
    • (1983) Journal of Applied Physiology , vol.54 , pp. 1653-1659
    • Lawrence, J.H.1    DeLuca, C.J.2
  • 27
  • 31
    • 1042286387 scopus 로고    scopus 로고
    • Femoral anteversion influences vastus medialis and gluteus medius EMG amplitude: composite hip abductor EMG amplitude ratios during isometric combined hip abduction-external rotation
    • Nyland J., Kuzemchek S., Parks M., and Caborn D.N. Femoral anteversion influences vastus medialis and gluteus medius EMG amplitude: composite hip abductor EMG amplitude ratios during isometric combined hip abduction-external rotation. Journal of Electromyography and Kinesiology 14 2 (2004) 255-261
    • (2004) Journal of Electromyography and Kinesiology , vol.14 , Issue.2 , pp. 255-261
    • Nyland, J.1    Kuzemchek, S.2    Parks, M.3    Caborn, D.N.4
  • 32
    • 0031044433 scopus 로고    scopus 로고
    • Reliability and precision of isokinetic strength and musclar endurance for the quadriceps and hamstrings
    • Pincivero D.M., Lephart S.M., and Karunakara R.A. Reliability and precision of isokinetic strength and musclar endurance for the quadriceps and hamstrings. International Journal of Sports Medicine 18 (1997) 113-117
    • (1997) International Journal of Sports Medicine , vol.18 , pp. 113-117
    • Pincivero, D.M.1    Lephart, S.M.2    Karunakara, R.A.3
  • 33
    • 0034004773 scopus 로고    scopus 로고
    • Activation linearity and parallelism of the superficial quadriceps across the isometric intensity spectrum
    • Pincivero D.M., and Coelho A.J. Activation linearity and parallelism of the superficial quadriceps across the isometric intensity spectrum. Muscle and Nerve 23 3 (2000) 393-398
    • (2000) Muscle and Nerve , vol.23 , Issue.3 , pp. 393-398
    • Pincivero, D.M.1    Coelho, A.J.2
  • 35
    • 33745192477 scopus 로고    scopus 로고
    • Assessment of hip extensor and flexor strength two months after unilateral total hip arthroplasty
    • Rossi M.D., Brown L.E., and Whitehurst M.A. Assessment of hip extensor and flexor strength two months after unilateral total hip arthroplasty. Journal of Strength and Conditioning Research 20 2 (2006) 262-267
    • (2006) Journal of Strength and Conditioning Research , vol.20 , Issue.2 , pp. 262-267
    • Rossi, M.D.1    Brown, L.E.2    Whitehurst, M.A.3
  • 36
    • 48249153186 scopus 로고
    • Intraclass correlations: uses in assessing rater reliability
    • Shrout P.E., and Fleiss J.L. Intraclass correlations: uses in assessing rater reliability. Psychological Bulletin 86 (1979) 420-428
    • (1979) Psychological Bulletin , vol.86 , pp. 420-428
    • Shrout, P.E.1    Fleiss, J.L.2
  • 38
    • 0035217966 scopus 로고    scopus 로고
    • Influence of joint position on electromyographic and torque generation during maximal voluntary isometric contractions of the hamstrings and gluteus maximus muscles
    • Worrell T.W., Karst G., Adamczyk D., Moore R., Stanley C., Steimel B., et al. Influence of joint position on electromyographic and torque generation during maximal voluntary isometric contractions of the hamstrings and gluteus maximus muscles. Journal of Orthopaedic and Sports Physical Therapy 31 12 (2001) 730-740
    • (2001) Journal of Orthopaedic and Sports Physical Therapy , vol.31 , Issue.12 , pp. 730-740
    • Worrell, T.W.1    Karst, G.2    Adamczyk, D.3    Moore, R.4    Stanley, C.5    Steimel, B.6
  • 39
    • 0021163138 scopus 로고
    • Electromyographic amplitude normalization methods: improving their sensitivity as diagnostic tools in gait analysis
    • Yang J.F., and Winter D.A. Electromyographic amplitude normalization methods: improving their sensitivity as diagnostic tools in gait analysis. Archives of Physical Medicine and Rehabilitation 65 (1984) 517-521
    • (1984) Archives of Physical Medicine and Rehabilitation , vol.65 , pp. 517-521
    • Yang, J.F.1    Winter, D.A.2
  • 40
    • 0020378690 scopus 로고
    • Recommendations for the standardization of lead positions in surface electromyography
    • Zipp P. Recommendations for the standardization of lead positions in surface electromyography. European Journal of Applied Physiology 50 (1982) 41-54
    • (1982) European Journal of Applied Physiology , vol.50 , pp. 41-54
    • Zipp, P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.