메뉴 건너뛰기




Volumn 19, Issue 5, 2009, Pages 1005-1012

Precision of measurements of physical workload during standardized manual handling part III: Goniometry of the wrists

Author keywords

Assembly work; Exposure variability; Inter subjects; Intra subjects

Indexed keywords

ACCURACY; ADULT; ARTICLE; CONTROLLED STUDY; ELECTROMYOGRAPHY; FEMALE; GONIOMETRY; HUMAN; HUMAN EXPERIMENT; MOVEMENT (PHYSIOLOGY); NORMAL HUMAN; PRIORITY JOURNAL; STANDARDIZATION; TASK PERFORMANCE; VELOCITY; WORKLOAD; WRIST;

EID: 68949167529     PISSN: 10506411     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jelekin.2008.07.003     Document Type: Article
Times cited : (21)

References (25)
  • 1
    • 33745143600 scopus 로고    scopus 로고
    • Changes in physical workload with implementation of mouse-based information technology in air traffic control
    • Arvidsson I., Hansson G.A., Mathiassen S.E., and Skerfving S. Changes in physical workload with implementation of mouse-based information technology in air traffic control. Int J Ind Med 36 (2006) 613-622
    • (2006) Int J Ind Med , vol.36 , pp. 613-622
    • Arvidsson, I.1    Hansson, G.A.2    Mathiassen, S.E.3    Skerfving, S.4
  • 4
    • 0031106209 scopus 로고    scopus 로고
    • Practical operation of a biaxial goniometer at the wrist joint
    • Buchholtz B., and Wellman H. Practical operation of a biaxial goniometer at the wrist joint. Human Factors 39 (1997) 119-129
    • (1997) Human Factors , vol.39 , pp. 119-129
    • Buchholtz, B.1    Wellman, H.2
  • 5
    • 18944361980 scopus 로고    scopus 로고
    • Ergonomics and musculoskeletal disorders: overview
    • Buckle P. Ergonomics and musculoskeletal disorders: overview. Occup Med 55 (2005) 164-167
    • (2005) Occup Med , vol.55 , pp. 164-167
    • Buckle, P.1
  • 6
    • 0036284574 scopus 로고    scopus 로고
    • The nature of work-related neck and upper limb musculoskeletal disorders
    • Buckle P.W., and Devereux J.J. The nature of work-related neck and upper limb musculoskeletal disorders. Appl Ergon 33 (2002) 207-217
    • (2002) Appl Ergon , vol.33 , pp. 207-217
    • Buckle, P.W.1    Devereux, J.J.2
  • 7
    • 0028122284 scopus 로고
    • The validity of visual observation to assess posture in a laboratory-simulated, manual material handling task
    • De Looze M.P., Toussaint H.M., Ensink J., and Mangnus C. The validity of visual observation to assess posture in a laboratory-simulated, manual material handling task. Ergonomics 37 (1994) 1335-1343
    • (1994) Ergonomics , vol.37 , pp. 1335-1343
    • De Looze, M.P.1    Toussaint, H.M.2    Ensink, J.3    Mangnus, C.4
  • 8
    • 0031214751 scopus 로고    scopus 로고
    • Optimal digital filtering requires a different cut-off frequency strategy for determination of the higher derivates
    • Giakas G., and Baltzopoulus V. Optimal digital filtering requires a different cut-off frequency strategy for determination of the higher derivates. J Biomech 30 (1997) 851-855
    • (1997) J Biomech , vol.30 , pp. 851-855
    • Giakas, G.1    Baltzopoulus, V.2
  • 9
    • 0002660280 scopus 로고    scopus 로고
    • Kinematic evaluation of occupational work
    • Hansson G.A., and Mikkelsen S. Kinematic evaluation of occupational work. Adv Occup Med Rehab 3 (1997) 57-69
    • (1997) Adv Occup Med Rehab , vol.3 , pp. 57-69
    • Hansson, G.A.1    Mikkelsen, S.2
  • 10
    • 0029933407 scopus 로고    scopus 로고
    • Goniometer measurements and computer analysis of wrist angels and movements applied to occupational repetitive work
    • Hansson G.A., Balogh I., Ohlsson K., Rylander L., and Skerfving S. Goniometer measurements and computer analysis of wrist angels and movements applied to occupational repetitive work. J Electromyogr Kinesiol 6 (1996) 23-35
    • (1996) J Electromyogr Kinesiol , vol.6 , pp. 23-35
    • Hansson, G.A.1    Balogh, I.2    Ohlsson, K.3    Rylander, L.4    Skerfving, S.5
  • 12
    • 0035102659 scopus 로고    scopus 로고
    • Questionnaire versus direct technical measurements in assessing postures and movements of the head, upper back, arms and hands
    • Hansson G.A., Balogh I., Unge Byström J., Ohlsson K., Nordander C., Asterland P., et al. Questionnaire versus direct technical measurements in assessing postures and movements of the head, upper back, arms and hands. Scand J Work Environ Health 27 (2001) 30-40
    • (2001) Scand J Work Environ Health , vol.27 , pp. 30-40
    • Hansson, G.A.1    Balogh, I.2    Unge Byström, J.3    Ohlsson, K.4    Nordander, C.5    Asterland, P.6
  • 13
    • 0038523785 scopus 로고    scopus 로고
    • Modular data logger system for physical workload measurements
    • Hansson G.A., Asterland P., and Kellerman M. Modular data logger system for physical workload measurements. Ergonomics 46 (2003) 407-415
    • (2003) Ergonomics , vol.46 , pp. 407-415
    • Hansson, G.A.1    Asterland, P.2    Kellerman, M.3
  • 14
    • 1942500257 scopus 로고    scopus 로고
    • Measurements of wrist and forearm positions and movements - effect of, and compensation for, goniometer crosstalk
    • Hansson G.A., Balogh I., Ohlsson K., and Skerfving S. Measurements of wrist and forearm positions and movements - effect of, and compensation for, goniometer crosstalk. J Electromyogr Kinesiol 14 (2004) 355-367
    • (2004) J Electromyogr Kinesiol , vol.14 , pp. 355-367
    • Hansson, G.A.1    Balogh, I.2    Ohlsson, K.3    Skerfving, S.4
  • 15
    • 31644450925 scopus 로고    scopus 로고
    • Precision of measurements of physical workload during standardised manual handling. Part II: inclinometry of head, upper back, neck and upper arms
    • Hansson G.A., Arvidsson I., Ohlsson K., Nordander C., Mathiassen S.E., Skerfving S., et al. Precision of measurements of physical workload during standardised manual handling. Part II: inclinometry of head, upper back, neck and upper arms. J Electromyogr Kinesiol 16 (2006) 125-136
    • (2006) J Electromyogr Kinesiol , vol.16 , pp. 125-136
    • Hansson, G.A.1    Arvidsson, I.2    Ohlsson, K.3    Nordander, C.4    Mathiassen, S.E.5    Skerfving, S.6
  • 17
    • 0036805467 scopus 로고    scopus 로고
    • Comparison of measurement accuracy between two wrist goniometer systems during pronation and supination
    • Johnson P.W., Jonsson P., and Hagberg M. Comparison of measurement accuracy between two wrist goniometer systems during pronation and supination. J Electromyogr Kinesiol 12 (2002) 413-420
    • (2002) J Electromyogr Kinesiol , vol.12 , pp. 413-420
    • Johnson, P.W.1    Jonsson, P.2    Hagberg, M.3
  • 18
    • 0034809370 scopus 로고    scopus 로고
    • Comparison of measurement accuracy between two types of wrist goniometer systems
    • Jonsson P., and Johnson P.W. Comparison of measurement accuracy between two types of wrist goniometer systems. Appl Ergon 32 (2001) 599-607
    • (2001) Appl Ergon , vol.32 , pp. 599-607
    • Jonsson, P.1    Johnson, P.W.2
  • 19
    • 68949191812 scopus 로고    scopus 로고
    • National Research Council (NRC) and the Institute of Medicine. Musculoskeletal disorders in the workplace: low back and upper extremities. Panel on musculoskeletal disorders in the workplace. Commission on Behavioural and Social Sciences and Education. Washington, DC: National Academy Press; 2001.
    • National Research Council (NRC) and the Institute of Medicine. Musculoskeletal disorders in the workplace: low back and upper extremities. Panel on musculoskeletal disorders in the workplace. Commission on Behavioural and Social Sciences and Education. Washington, DC: National Academy Press; 2001.
  • 20
    • 2542588541 scopus 로고    scopus 로고
    • Precision of measurements of physical workload during standardised manual handling. Part I: surface electromyography of M. trapezius, M. infraspinatus and the forearm extensors
    • Nordander C., Balogh I., Mathiassen S.E., Ohlsson K., Unge J., Skerfving S., et al. Precision of measurements of physical workload during standardised manual handling. Part I: surface electromyography of M. trapezius, M. infraspinatus and the forearm extensors. J Electromyogr Kinesiol 14 (2004) 443-454
    • (2004) J Electromyogr Kinesiol , vol.14 , pp. 443-454
    • Nordander, C.1    Balogh, I.2    Mathiassen, S.E.3    Ohlsson, K.4    Unge, J.5    Skerfving, S.6
  • 21
    • 0027587898 scopus 로고
    • An analytical method for characterizing repetitive motion and postural stress using spectral analysis
    • Radwin R.G., and Lin M.L. An analytical method for characterizing repetitive motion and postural stress using spectral analysis. Ergonomics 36 (1993) 379-389
    • (1993) Ergonomics , vol.36 , pp. 379-389
    • Radwin, R.G.1    Lin, M.L.2
  • 22
    • 0034980398 scopus 로고    scopus 로고
    • Criteria document for evaluating the work-relatedness of upper-extremity musculoskeletal disorders
    • Sluiter J.K., Rest K.M., and Frings-Dresen M.H. Criteria document for evaluating the work-relatedness of upper-extremity musculoskeletal disorders. Scand J Work Environ Health 27 Suppl. 1 (2001) 1-102
    • (2001) Scand J Work Environ Health , vol.27 , Issue.SUPPL. 1 , pp. 1-102
    • Sluiter, J.K.1    Rest, K.M.2    Frings-Dresen, M.H.3
  • 23
    • 0035873716 scopus 로고    scopus 로고
    • Comparison of self-report, video observation and direct measurement methods for upper extremity musculoskeletal disorder physical risk factors
    • Spielholz P., Silverstein B., Morgan M., Checkoway H., and Kaufman J. Comparison of self-report, video observation and direct measurement methods for upper extremity musculoskeletal disorder physical risk factors. Ergonomics 44 (2001) 588-613
    • (2001) Ergonomics , vol.44 , pp. 588-613
    • Spielholz, P.1    Silverstein, B.2    Morgan, M.3    Checkoway, H.4    Kaufman, J.5
  • 24
    • 11344269178 scopus 로고    scopus 로고
    • Task-based exposure assessment in ergonomic epidemiology: a study of upper arm elevation in the jobs of machinists, car mechanics, and house painters
    • Svendsen S.W., Mathiassen S.E., and Bonde J.P. Task-based exposure assessment in ergonomic epidemiology: a study of upper arm elevation in the jobs of machinists, car mechanics, and house painters. Occup Environ Med 62 (2005) 18-26
    • (2005) Occup Environ Med , vol.62 , pp. 18-26
    • Svendsen, S.W.1    Mathiassen, S.E.2    Bonde, J.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.