메뉴 건너뛰기




Volumn 26, Issue 3, 2009, Pages 145-149

Engineering aspects of the quantified amplitude-integrated electroencephalogram in neonatal cerebral monitoring

Author keywords

Amplitude EEG; EEG; Hypothermia therapy; Hypoxic ischemic encephalopathy; Neonatal monitoring

Indexed keywords

ARTICLE; BRAIN ISCHEMIA; DEVICE; ELECTRODE; ELECTROENCEPHALOGRAM; HUMAN; HYPOTHERMIA; IMPEDANCE; PATIENT MONITORING; BIOMEDICAL ENGINEERING; BRAIN; BRAIN DISEASE; COMPARATIVE STUDY; COMPUTER ASSISTED DIAGNOSIS; EQUIPMENT; EQUIPMENT DESIGN; EVALUATION; FEMALE; INSTRUMENTATION; MALE; METHODOLOGY; NEWBORN; PATHOPHYSIOLOGY; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; SYSTEM ANALYSIS;

EID: 68849116019     PISSN: 07360258     EISSN: None     Source Type: Journal    
DOI: 10.1097/WNP.0b013e3181a18711     Document Type: Article
Times cited : (28)

References (13)
  • 1
    • 40849116197 scopus 로고    scopus 로고
    • Anesthesia awareness and the bispectral index
    • Avidan MS, Zhang L, Burnside BA, et al. Anesthesia awareness and the bispectral index. N Engl J Med. 2008;358:1097-1108.
    • (2008) N Engl J Med , vol.358 , pp. 1097-1108
    • Avidan, M.S.1    Zhang, L.2    Burnside, B.A.3
  • 2
    • 0141959083 scopus 로고    scopus 로고
    • Cerebral function monitoring: A new scoring system for the evaluation of brain maturation in neonates
    • DOI 10.1542/peds.112.4.855
    • Burdjalov VF, Baumgart S, Spitzer AR. Cerebral function monitoring: a new scoring system for the evaluation of brain maturation in neonates. Pediatrics. 2003;112:855-861. (Pubitemid 37248694)
    • (2003) Pediatrics , vol.112 , Issue.4 , pp. 855-861
    • Burdjalov, V.F.1    Baumgart, S.2    Spitzer, A.R.3
  • 5
    • 0028832920 scopus 로고
    • Predictive value of early continuous amplitude integrated EEG recordings on outcome after severe birth asphyxia in full term infants
    • Hellström-Westas L, Rosen I, Svenningsen N. Predictive value of early continuous amplitude integrated EEG recordings on outcome after severe birth asphyxia in full term infants. Arch Dis Child Fetal Neonatal Ed. 1995;72:34-38.
    • (1995) Arch Dis Child Fetal Neonatal Ed , vol.72 , pp. 34-38
    • Hellström-Westas, L.1    Rosen, I.2    Svenningsen, N.3
  • 7
    • 2542562742 scopus 로고    scopus 로고
    • Bispectral index monitoring to prevent awareness during anaesthesia: The B-Aware randomised controlled trial
    • DOI 10.1016/S0140-6736(04)16300-9, PII S0140673604163009
    • Myles PS, Leslie K, McNeil J, et al. Bispectral index monitoring to prevent awareness during anaesthesia: the B-Aware randomised controlled trial. Lancet. 2004;363:1757-1763. (Pubitemid 38698378)
    • (2004) Lancet , vol.363 , Issue.9423 , pp. 1757-1763
    • Myles, P.S.1    Leslie, K.2    McNeil, J.3    Forbes, A.4    Chan, M.T.V.5
  • 8
    • 0014765311 scopus 로고
    • A new device for continuous monitoring of cerebral activity: Its use following cerebral anoxia
    • Prior PF, Maynard D, Scott DF. A new device for continuous monitoring of cerebral activity: its use following cerebral anoxia. Electroencephalogr Clin Neurophysiol. 1970;28:423-424.
    • (1970) Electroencephalogr Clin Neurophysiol , vol.28 , pp. 423-424
    • Prior, P.F.1    Maynard, D.2    Scott, D.F.3
  • 10
    • 38949187924 scopus 로고    scopus 로고
    • Should amplitude-integrated electroencephalography be used to identify infants suitable for hypothermic neuroprotection?
    • DOI 10.1038/sj.jp.7211882, PII 7211882
    • Sarkar S, Barks JD, Donn SM. Should amplitude-integrated electroencephalography be used to identify infants suitable for hypothermic neuroprotection. J Perinatol. 2008;28:117-122. (Pubitemid 351217638)
    • (2008) Journal of Perinatology , vol.28 , Issue.2 , pp. 117-122
    • Sarkar, S.1    Barks, J.D.2    Donn, S.M.3
  • 11
    • 33746786517 scopus 로고    scopus 로고
    • Use of 2-channel bedside electroencephalogram monitoring in term-born encephalopathic infants related to cerebral injury defined by magnetic resonance imaging
    • DOI 10.1542/peds.2005-1294
    • Shah DK, Lavery S, Doyle LW, et al. Use of 2-channel bedside electroencephalogram monitoring in term-born encephalopathic infants related to cerebral injury defined by magnetic resonance imaging. Pediatrics. 2006;118:47-55. (Pubitemid 46071146)
    • (2006) Pediatrics , vol.118 , Issue.1 , pp. 47-55
    • Shah, D.K.1    Lavery, S.2    Doyle, L.W.3    Wong, C.4    McDougall, P.5    Inder, T.E.6
  • 12
    • 0037315259 scopus 로고    scopus 로고
    • Amplitude-integrated electroencephalography coupled with an early neurologic examination enhances prediction of term infants at risk for persistent encephalopathy
    • Shalak LF, Laptook AR, Velaphi SC, et al. Amplitude-integrated electroencephalography coupled with an early neurologic examination enhances prediction of term infants at risk for persistent encephalopathy. Pediatrics. 2003;111:351-357.
    • (2003) Pediatrics , vol.111 , pp. 351-357
    • Shalak, L.F.1    Laptook, A.R.2    Velaphi, S.C.3
  • 13
    • 0036247410 scopus 로고    scopus 로고
    • Comparison between simultaneously recorded amplitude integrated electroencephalogram (cerebral function monitor) and standard electroencephalogram in neonates
    • Toet MC, van der Meij W, de Vries LS, et al. Comparison between simultaneously recorded amplitude integrated electroencephalogram (cerebral function monitor) and standard electroencephalogram in neonates. Pediatrics. 2002;109:772-779.
    • (2002) Pediatrics , vol.109 , pp. 772-779
    • Toet, M.C.1    Van Der Meij, W.2    De Vries, L.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.