-
1
-
-
0035140995
-
Mechanical cardiac support 2000: Current applications and future trial design
-
DOI 10.1016/S1053-2498(00)01099-8, PII S1053249800010998
-
Stevenson LW, Kormos RL: Mechanical cardiac support 2000: Current applications and future trial design. J Heart Lung Transplant 20: 1-38, 2001. (Pubitemid 32112383)
-
(2001)
Journal of Heart and Lung Transplantation
, vol.20
, Issue.1
, pp. 1-38
-
-
Stevenson, L.W.1
Kormos, R.L.2
-
2
-
-
0032170919
-
Characterization and optimization of the flow pattern inside a diaphragm blood pump based on flow visualization techniques
-
Nakata M, Masuzawa T, Tatsumi E, et al: Characterization and optimization of the flow pattern inside a diaphragm blood pump based on flow visualization techniques. ASAIO J 44: M714-M718, 1998. (Pubitemid 28468933)
-
(1998)
ASAIO Journal
, vol.44
, Issue.5
-
-
Nakata, M.1
Masuzawa, T.2
Tatsumi, E.3
Taenaka, Y.4
Nishimura, T.5
Tsukiya, T.6
Takano, H.7
Tsuchimoto, K.8
Ohba, K.9
-
3
-
-
35348899858
-
Advanced technologies for cardiac valvular replacement, transcatheter innovations and reconstructive surgery
-
Jamieson WR: Advanced technologies for cardiac valvular replacement, transcatheter innovations and reconstructive surgery. Surg Technol Int 15: 149-187, 2006.
-
(2006)
Surg Technol Int
, vol.15
, pp. 149-187
-
-
Jamieson, W.R.1
-
4
-
-
0028231956
-
Cavitation damage of pyrolytic carbon in mechanical heart valves
-
Kafesjian R, Howanec M, Ward GD, et al: Cavitation damage of pyrolytic carbon in mechanical heart valves. J Heart Valve Dis 3: S2-S7, 1994. (Pubitemid 24150695)
-
(1994)
Journal of Heart Valve Disease
, vol.3
, Issue.SUPPL. 1
-
-
Kafesjian, R.1
Howanec, M.2
Ward, G.D.3
Diep, L.4
Wagstaff, L.S.5
Rhee, R.6
-
5
-
-
38349141343
-
Characterization of hemodynamic forces induced by mechanical heart valve: Reynolds vs. viscous stresses
-
Ge L, Dasi LP, Sotiropoulos F, Yoganathan AP: Characterization of hemodynamic forces induced by mechanical heart valve: Reynolds vs. viscous stresses.Ann Biomed Eng36: 276-297, 2007.
-
(2007)
Ann Biomed Eng
, vol.36
, pp. 276-297
-
-
Ge, L.1
Dasi, L.P.2
Sotiropoulos, F.3
Yoganathan, A.P.4
-
6
-
-
0015309999
-
Red blood cell damage by shear stress
-
Leverett LB, Hellums JD, Alfrey CP, Lynch EC: Red blood cell damage by shear stress. Biophys J 12: 257-273, 1972.
-
(1972)
Biophys J
, vol.12
, pp. 257-273
-
-
Leverett, L.B.1
Hellums, J.D.2
Alfrey, C.P.3
Lynch, E.C.4
-
7
-
-
23044503759
-
An experimental study of steady flow patterns of a new trileaflet mechanical aortic valve
-
Liu JS, Lu PC, Lo CW, et al: An experimental study of steady flow patterns of a new trileaflet mechanical aortic valve. ASAIO J 51: 336-341, 2005.
-
(2005)
ASAIO J
, vol.51
, pp. 336-341
-
-
Liu, J.S.1
Lu, P.C.2
Lo, C.W.3
-
8
-
-
0034791973
-
Pulsatile flow studies of a porcine bioprosthetic aortic valve in vitro: PIV measurements and shear-induced blood damage
-
Lim WL, Chew YT, Chew TC, Low HT: Pulsatile flow studies of a porcine bioprosthetic aortic valve in vitro: PIV measurements and shear-induced blood damage. J Biomech 34:1417-1427, 2001.
-
(2001)
J Biomech
, vol.34
, pp. 1417-1427
-
-
Lim, W.L.1
Chew, Y.T.2
Chew, T.C.3
Low, H.T.4
-
9
-
-
0035063176
-
The influence of the leaflets' curvature on the flow field in two bileaflet prosthetic heart valves
-
DOI 10.1016/S0021-9290(00)00240-2, PII S0021929000002402
-
Grigioni M, Daniele C, D'Avenio G, Barbaro V: The influence of the leaflets' curvature on the flow field in two bileaflet prosthetic heart valves. J Biomech 34: 613-621, 2001. (Pubitemid 32328249)
-
(2001)
Journal of Biomechanics
, vol.34
, Issue.5
, pp. 613-621
-
-
Grigioni, M.1
Daniele, C.2
D'Avenio, G.3
Barbaro, V.4
-
10
-
-
2542439910
-
Numerical estimation of blood damage in artificial organs
-
DOI 10.1111/j.1525-1594.2004.07265.x
-
Goubergrits L, Affeld K: Numerical estimation of blood damage in artificial organs. Artif Organs 28: 499-507, 2004. (Pubitemid 38684153)
-
(2004)
Artificial Organs
, vol.28
, Issue.5
, pp. 499-507
-
-
Goubergrits, L.1
Affeld, K.2
-
11
-
-
33748991701
-
Dynamic particle image velocimetry flow analysis of the flow field immediately downstream of bileaflet mechanical mitral prostheses
-
DOI 10.1007/s10047-006-0340-5
-
Akutsu T, Saito J: Dynamic particle image velocimetry flow analysis of the flow field immediately downstream of bileaflet mechanical mitral prostheses.J Artif Organs 9: 165-178, 2006. (Pubitemid 44453867)
-
(2006)
Journal of Artificial Organs
, vol.9
, Issue.3
, pp. 165-178
-
-
Akutsu, T.1
Saito, J.2
-
12
-
-
2542443814
-
Particle image velocimetry for flow analysis in longitudinal planes across a mechanical artificial heart valve
-
DOI 10.1111/j.1525-1594.2004.07271.x
-
Castellini P, Pinotti M, Scalise L: Particle image velocimetry for flow analysis in longitudinal planes across a mechanical artificial heart valve.Artif Organs 28: 507-513, 2004. (Pubitemid 38680165)
-
(2004)
Artificial Organs
, vol.28
, Issue.5
, pp. 507-513
-
-
Castellini, P.1
Pinotti, M.2
Scalise, L.3
-
13
-
-
0033774274
-
Particle image velocimetry investigation of intra-valvular flow fields of a bileaflet mechanical heart valve in a pulsatile flow
-
Subramanian A, Mu H, Kadambi JR, et al: Particle image velocimetry investigation of intravalvular flow fields of a bileaflet mechanical heart valve in a pulsatile flow. J Heart Valve Dis 9: 721-731, 2000. (Pubitemid 30768021)
-
(2000)
Journal of Heart Valve Disease
, vol.9
, Issue.5
, pp. 721-731
-
-
Subramanian, A.1
Mu, H.2
Kadambi, J.R.3
Wernet, M.P.4
Brendzel, A.M.5
Harasaki, H.6
-
14
-
-
34250776505
-
Hydrodynamic characteristics of bileaflet mechanical heart valves in an artificial heart: Cavitation and closing velocity
-
DOI 10.1111/j.1525-1594.2007.00419.x
-
Lee HS, Homma A, Taenaka Y: Hydrodynamic characteristics of bileaflet mechanical heart valve in an artificial heart: cavitation and closing velocity. Artif Organs 31: 532-537, 2007. (Pubitemid 46961708)
-
(2007)
Artificial Organs
, vol.31
, Issue.7
, pp. 532-537
-
-
Lee, H.1
Homma, A.2
Taenaka, Y.3
-
15
-
-
2542490237
-
Flow pattern and shear stress distribution of distal end-to-side anastomoses. A comparison of the instantaneous velocity fields obtained by particle image velocimetry
-
DOI 10.1016/j.jbiomech.2003.11.030, PII S0021929003004330
-
Heise M, Schmidt S, Krüger U, et al: Flow pattern and shear stress distribution of distal end-to-side anastomoses. A comparison of the instantaneous velocity fields obtained by particle image velocimetry. J Biomech 37: 1043-1051, 2004. (Pubitemid 38686328)
-
(2004)
Journal of Biomechanics
, vol.37
, Issue.7
, pp. 1043-1051
-
-
Heise, M.1
Schmidt, S.2
Kruger, U.3
Ruckert, R.4
Rosler, S.5
Neuhaus, P.6
Settmacher, U.7
-
16
-
-
36448990814
-
Flow visualization through two types of aortic prosthetic heart valves using stereoscopic high-speed particle image velocimetry
-
DOI 10.1111/j.1525-1594.2007.00471.x
-
Kaminsky R, Kallweit S, Weber HJ, et al: Flow visualization through two types of aortic prosthetic heart valves using ste- roscoptic high-speed particle image velocimetry. Artif Organs 31: 869-879, 2007. (Pubitemid 350173646)
-
(2007)
Artificial Organs
, vol.31
, Issue.12
, pp. 869-879
-
-
Kaminsky, R.1
Kallweit, S.2
Weber, H.-J.3
Claessens, T.4
Jozwik, K.5
Verdonck, P.6
-
17
-
-
34648858628
-
Shear stress investigation across mechanical heart valve
-
DOI 10.1097/MAT.0b013e318157c093, PII 0000248020070900000002
-
Zhang P, Yeo JH, Qian P, Hwang NHC: Shear stress investigation across mechanical heart valve. ASAIO J 53: 530-536, 2007. (Pubitemid 47462246)
-
(2007)
ASAIO Journal
, vol.53
, Issue.5
, pp. 530-536
-
-
Zhang, P.1
Yeo, J.H.2
Qian, P.3
Hwang, N.H.C.4
-
18
-
-
44849101756
-
Characteristics of mechanical heart valve cavitation in a pneumatic ventricular assist device
-
DOI 10.1111/j.1525-1594.2008.00564.x
-
Lee HS, Taenaka Y: Characteristics of mechanical heart valve cavitation in a pneumatic ventricular assist device. Artif Organs 32: 453-460, 2008. (Pubitemid 351798386)
-
(2008)
Artificial Organs
, vol.32
, Issue.6
, pp. 453-460
-
-
Lee, H.1
Taenaka, Y.2
-
19
-
-
34447311421
-
Effects of mechanical valve orifice direction on the flow pattern in a ventricular assist device
-
DOI 10.1007/s10047-007-0378-z
-
Akagawa E, Lee HS, Tatsumi E, et al: Effects of mechanical valve orifice direction on flow pattern in a ventricular assist device. J Artif Organs 10: 85-91, 2007. (Pubitemid 47051350)
-
(2007)
Journal of Artificial Organs
, vol.10
, Issue.2
, pp. 85-91
-
-
Akagawa, E.1
Lee, H.2
Tatsumi, E.3
Homma, A.4
Tsukiya, T.5
Katagiri, N.6
Kakuta, Y.7
Nishinaka, T.8
Mizuno, T.9
Ota, K.10
Kansaku, R.11
Taenaka, Y.12
-
20
-
-
0016617573
-
Design of a hydraulic analog of the circulatory system for evaluating artificial hearts
-
Donovan FM Jr: Design of a hydraulic analog of the circulatory system for evaluating artificial hearts. Biomater Med Devices Artif Organs 3: 439-449, 1975.
-
(1975)
Biomater Med Devices Artif Organs
, vol.3
, pp. 439-449
-
-
Donovan Jr., F.M.1
-
21
-
-
11244354978
-
Observation of cavitation bubbles in monoleaflet mechanical heart valves
-
DOI 10.1007/s10047-004-0258-8
-
Lee HS, Tsukiya T, Homma A, et al: Observation of cavitation bubbles in monoleaflet mechanical heart valves. J Artif Organs 7: 121-127, 2004. (Pubitemid 40064336)
-
(2004)
Journal of Artificial Organs
, vol.7
, Issue.3
, pp. 121-127
-
-
Lee, H.1
Tsukiya, T.2
Homma, A.3
Kamimura, T.4
Takewa, Y.5
Tatsumi, E.6
Taenaka, Y.7
Takano, H.8
Kitamura, S.9
-
22
-
-
18744390793
-
Mechanisms of mechanical heart valve cavitation in an electrohydraulic total artificial heart
-
DOI 10.1097/01.MAT.0000159383.40133.92
-
Lee HS, Taenaka Y, Kitamura S: Mechanisms of mechanical heart valve cavitation in an electrohydraulic total artificial heart. ASAIO J 51: 208-213, 2005. (Pubitemid 40677128)
-
(2005)
ASAIO Journal
, vol.51
, Issue.3
, pp. 208-213
-
-
Lee, H.1
Taenaka, Y.2
Kitamura, S.3
-
23
-
-
18744366137
-
Design and in vitro performance of a novel bileaflet mechanical heart valve prosthesis
-
Medart D, Schmitz C, Rau G, Reul H: Design and in vitro performance of a novel bileaflet mechanical heart valve prosthesis. Int J Artif Organs 28: 256-263, 2005. (Pubitemid 40667615)
-
(2005)
International Journal of Artificial Organs
, vol.28
, Issue.3
, pp. 256-263
-
-
Medart, D.1
Schmitz, C.2
Rau, G.3
Reul, H.4
-
24
-
-
3142738195
-
The closing behavior of mechanical aortic heart valve prostheses
-
Lu PC, Liu JS, Huang RH, et al: The closing behavior of mechanical heart valve prostheses. ASAIO J 50: 294-300, 2004. (Pubitemid 38917873)
-
(2004)
ASAIO Journal
, vol.50
, Issue.4
, pp. 294-300
-
-
Lu, P.-C.1
Liu, J.-S.2
Huang, R.-H.3
Lo, C.-W.4
Lai, H.-C.5
Hwang, N.H.C.6
-
25
-
-
0026911181
-
Cavitation of mechanical heartvalves under physiologic conditions
-
Graf T, Reul H, Dietz W, et al: Cavitation of mechanical heartvalves under physiologic conditions. J Heart Valve Dis 1: 131-141, 1992.
-
(1992)
J Heart Valve Dis
, vol.1
, pp. 131-141
-
-
Graf, T.1
Reul, H.2
Dietz, W.3
-
26
-
-
0021685904
-
Human red blood cell hemolysis in a turbulence shear flow: Contribution of Reynolds shear stresses
-
Sallam AM, Hwang NHC: Human red blood cell hemolysis in a turbulence shear flow: contribution of Reynolds shear stresses. Biorheology 21: 783-797, 1984.
-
(1984)
Biorheology
, vol.21
, pp. 783-797
-
-
Sallam, A.M.1
Nhc, H.2
|