Volumn 40, Issue 8, 2009, Pages 2875-2878

Avoiding "pseudo-Reversibility" of CT-CBV infarct core lesions in acute stroke patients after thrombolytic therapy: The need for algorithmically "delay-Corrected" CT perfusion map postprocessing software

Author keywords

CT perfusion; Stroke management

Indexed keywords

FIBRINOLYTIC AGENT; IOPAMIDOL;

EID: 68749110793     PISSN: 00392499     EISSN: None     Source Type: Journal    
DOI: 10.1161/STROKEAHA.109.547679     Document Type: Article
Times cited : (41)

References (6)
  • 1
    • 55749108505 scopus 로고    scopus 로고
    • Quantitative assessment of core/penumbra mismatch in acute stroke: CT and MR perfusion imaging are strongly correlated when sufficient brain volume is imaged
    • Schaefer PW, Barak ER, Kamalian S, Gharai LR, Schwamm L, Gonzalez RG, Lev MH. Quantitative assessment of core/penumbra mismatch in acute stroke: CT and MR perfusion imaging are strongly correlated when sufficient brain volume is imaged. Stroke. 2008;39:2986-2992.
    • (2008) Stroke , vol.39 , pp. 2986-2992
    • Schaefer, P.W.1    Barak, E.R.2    Kamalian, S.3    Gharai, L.R.4    Schwamm, L.5    Gonzalez, R.G.6    Lev, M.H.7
  • 2
    • 0033812331 scopus 로고    scopus 로고
    • Delay and dispersion effects in dynamic susceptibility contrast MRI: Simulations using singular value decomposition
    • Calamante F, Gadian DG, Connelly A. Delay and dispersion effects in dynamic susceptibility contrast MRI: simulations using singular value decomposition. Magn Reson Med. 2000;44:466-473.
    • (2000) Magn Reson Med , vol.44 , pp. 466-473
    • Calamante, F.1    Gadian, D.G.2    Connelly, A.3
  • 5
    • 0032888685 scopus 로고    scopus 로고
    • CT assessment of cerebral perfusion: Experimental validation and initial clinical experience
    • Nabavi DG, Cenic A, Craen RA, Gelb AW, Bennett JD, Kozak R, Lee TY. CT assessment of cerebral perfusion: experimental validation and initial clinical experience. Radiology. 1999;213:141-149.
    • (1999) Radiology , vol.213 , pp. 141-149
    • Nabavi, D.G.1    Cenic, A.2    Craen, R.A.3    Gelb, A.W.4    Bennett, J.D.5    Kozak, R.6    Lee, T.Y.7
  • 6
    • 0037344519 scopus 로고    scopus 로고
    • Quantitative cerebral blood flow measurement with dynamic perfusion ct using the vascular-pixel elimination method: Comparison with h2(15)o positron emission tomography
    • Kudo K, Terae S, Katoh C, Oka M, Shiga T, Tamaki N, Miyasaka K. Quantitative cerebral blood flow measurement with dynamic perfusion ct using the vascular-pixel elimination method: comparison with h2(15)o positron emission tomography. AJNR. 2003;24:419-426.
    • (2003) AJNR , vol.24 , pp. 419-426
    • Kudo, K.1    Terae, S.2    Katoh, C.3    Oka, M.4    Shiga, T.5    Tamaki, N.6    Miyasaka, K.7