메뉴 건너뛰기




Volumn 36, Issue 3, 2009, Pages 598-599

Carbon dioxide embolism induced right coronary artery ischaemia during off-pump obtuse marginalis artery grafting

Author keywords

Coronary bypass; Gas embolism; Off pump surgery

Indexed keywords

CARBON DIOXIDE; CREATINE KINASE MB; NORADRENALIN; SILICONE; VASOPRESSIN;

EID: 68749098110     PISSN: 10107940     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejcts.2009.04.062     Document Type: Article
Times cited : (13)

References (7)
  • 1
    • 0037531439 scopus 로고    scopus 로고
    • Future technology for off-pump coronary bypass
    • Aklog L. Future technology for off-pump coronary bypass. Semin Thorac Cardiovasc Surg 15 (2003) 92-102
    • (2003) Semin Thorac Cardiovasc Surg , vol.15 , pp. 92-102
    • Aklog, L.1
  • 2
    • 1342303771 scopus 로고    scopus 로고
    • Off-pump coronary artery bypass surgery: physiology and anaesthetic management
    • Chassot P.G., van der Linden P., Zaugg M., Mueller X.M., and Spahn D.R. Off-pump coronary artery bypass surgery: physiology and anaesthetic management. Br J Anaesth 92 (2004) 400-413
    • (2004) Br J Anaesth , vol.92 , pp. 400-413
    • Chassot, P.G.1    van der Linden, P.2    Zaugg, M.3    Mueller, X.M.4    Spahn, D.R.5
  • 3
    • 57549103982 scopus 로고    scopus 로고
    • Massive systemic air embolism during off-pump coronary artery surgery
    • Kuralay E. Massive systemic air embolism during off-pump coronary artery surgery. Eur J Cardiothorac Surg 35 (2009) 183-184
    • (2009) Eur J Cardiothorac Surg , vol.35 , pp. 183-184
    • Kuralay, E.1
  • 4
    • 0029552835 scopus 로고
    • Carbon dioxide gas blow for the safe visualization of coronary artery anastomosis
    • Sasaguri S., Hosoda Y., and Yamamoto S. Carbon dioxide gas blow for the safe visualization of coronary artery anastomosis. Ann Thorac Surg 60 (1995) 1861
    • (1995) Ann Thorac Surg , vol.60 , pp. 1861
    • Sasaguri, S.1    Hosoda, Y.2    Yamamoto, S.3
  • 5
    • 40649113311 scopus 로고    scopus 로고
    • Prediction of cognitive dysfunction and patients' outcome following valvular heart surgery and the role of cerebral oximetry
    • Hong S.W., Shim J.K., Choi Y.S., Kim D.H., Chang B.C., and Kwak Y.L. Prediction of cognitive dysfunction and patients' outcome following valvular heart surgery and the role of cerebral oximetry. Eur J Cardiothorac Surg 33 (2008) 560-565
    • (2008) Eur J Cardiothorac Surg , vol.33 , pp. 560-565
    • Hong, S.W.1    Shim, J.K.2    Choi, Y.S.3    Kim, D.H.4    Chang, B.C.5    Kwak, Y.L.6
  • 6
    • 1542411428 scopus 로고    scopus 로고
    • 2 insufflation on the number and behavior of air microemboli in open heart surgery: a randomized clinical trial
    • 2 insufflation on the number and behavior of air microemboli in open heart surgery: a randomized clinical trial. Circulation 109 (2004) 1127-1132
    • (2004) Circulation , vol.109 , pp. 1127-1132
    • Svenarud, P.1    Persson, M.2    van der Linden, J.3
  • 7
    • 34648831370 scopus 로고    scopus 로고
    • Massive carbon dioxide embolism caused by a carbon dioxide blower during repair of a coronary vein during off-pump coronary artery bypass
    • Lee J.H., Yoon S.Z., Choi J.Y., Bahk J.H., and Jeon Y.S. Massive carbon dioxide embolism caused by a carbon dioxide blower during repair of a coronary vein during off-pump coronary artery bypass. J Cardiothorac Vasc Anesth 21 (2007) 715-717
    • (2007) J Cardiothorac Vasc Anesth , vol.21 , pp. 715-717
    • Lee, J.H.1    Yoon, S.Z.2    Choi, J.Y.3    Bahk, J.H.4    Jeon, Y.S.5