High risk infusions - Accuracy compromised by changes in patient venous pressure

Author keywords

Drug delivery; Flow error; Infusion pump

Indexed keywords

BOLUS FLOWS; FLOW ERROR; FLOW VARIATIONS; HIGH POTENCY; INFUSION DEVICES; INFUSION PUMP; INTENSIVE CARE; LOW FLOW; MECHANICAL COMPLIANCE; RIGID COMPONENTS; SLOW START; SYSTEM DYNAMICS; TRANSIENT FLOW CHARACTERISTICS; VENOUS PRESSURE;

EID: 68649098077     PISSN: 03091902     EISSN: 1464522X     Source Type: Journal    
DOI: 10.1080/03091900902952659     Document Type: Article
Times cited : (6)

References (8)
  • 2
    • 68649107272 scopus 로고    scopus 로고
    • Medical Devices Agency. DB 2003(02) (London: MDA)
    • Medical Devices Agency. 2003, Infusion Systems - Device Bulletin, DB 2003(02) (London: MDA).
    • (2003) Infusion Systems - Device Bulletin
  • 3
    • 0029995439 scopus 로고    scopus 로고
    • Disturbance of continuous, pump administration of cardiovascular drugs by hydrostatic pressure
    • Krauskopf, K.H., Rauscher, J. and Brandt, L., 1996, Disturbance of continuous, pump administration of cardiovascular drugs by hydrostatic pressure. Der Anaesthesist, 45, 449-452.
    • (1996) Der Anaesthesist , vol.45 , pp. 449-452
    • Krauskopf, K.H.1    Rauscher, J.2    Brandt, L.3
  • 5
    • 0035089356 scopus 로고    scopus 로고
    • Infusion pump performance with vertical displacement: Effect of syringe pump and assembly type
    • DOI 10.1007/s001340000784
    • Neff, T.A., Fischer, J.E., Schultz, G., Baenziger, O. and Weiss, M., 2001, Infusion pump performance with vertical displacement: effect of syringe pump and assembly type. Intensive Care Medicine, 27, 287-291. (Pubitemid 32209002)
    • (2001) Intensive Care Medicine , vol.27 , Issue.1 , pp. 287-291
    • Neff, T.A.1    Fischer, J.E.2    Schulz, G.3    Baenziger, O.4    Weiss, M.5
  • 6
    • 0030695421 scopus 로고    scopus 로고
    • Design flaw can convert commercially available continuous syringe pumps to intermittent bolus injectors
    • DOI 10.1007/s001340050445
    • Lonnqvist, P.A. and Lofqvist, B., 1997, Design flaw can convert commercially available continuous syringe pumps to intermittent bolus injectors. Intensive Care Medicine, 23, 998-1001. (Pubitemid 27464710)
    • (1997) Intensive Care Medicine , vol.23 , Issue.9 , pp. 998-1001
    • Lonnqvist, P.A.1    Lofqvist, B.2
  • 7
    • 0033936276 scopus 로고    scopus 로고
    • Influence of infusion line compliance on drug delivery rate during acute line loop formation
    • Weiss, M., Banziger, O., Neff, T. and Fanconi, S., 2000, Influence of infusion line compliance on drug delivery rate during acute line loop formation. Intensive Care Medicine, 26, 776-779. (Pubitemid 30449673)
    • (2000) Intensive Care Medicine , vol.26 , Issue.6 , pp. 776-779
    • Weiss, M.1    Banziger, O.2    Neff, T.3    Fanconi, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.