메뉴 건너뛰기




Volumn 35, Issue 2, 2009, Pages 44-49

In situ visualization of tears on contact lens using ultra high resolution optical coherence tomography

Author keywords

Contact lens; Optical coherence tomography; Tear dynamics

Indexed keywords

ARTIFICIAL TEAR; INTRALIPID;

EID: 68549102005     PISSN: 15422321     EISSN: None     Source Type: Journal    
DOI: 10.1097/ICL.0b013e31819579f2     Document Type: Article
Times cited : (56)

References (13)
  • 1
    • 43949136272 scopus 로고    scopus 로고
    • The prevalence of dry eye in contact lens wearers: Part 2 of the Canadian Dry Eye Epidemiology study
    • Caffery B, Richter D, Simpson T, et al. The prevalence of dry eye in contact lens wearers: Part 2 of the Canadian Dry Eye Epidemiology study. Optom Vis Sci 1996;73:109.
    • (1996) Optom Vis Sci , vol.73 , pp. 109
    • Caffery, B.1    Richter, D.2    Simpson, T.3
  • 2
    • 0031745464 scopus 로고    scopus 로고
    • CANDEES. The Canadian Dry Eye Epidemiology Study
    • Caffery BE, Richter D, Simpson T, et al. CANDEES. The Canadian Dry Eye Epidemiology Study. Adv Exp Med Biol 1998;438:805-806.
    • (1998) Adv Exp Med Biol , vol.438 , pp. 805-806
    • Caffery, B.E.1    Richter, D.2    Simpson, T.3
  • 3
    • 0027985314 scopus 로고
    • Micrometer-scale resolution imaging of the anterior eye in vivo with optical coherence tomography
    • Izatt JA, Hee MR, Swanson EA, et al. Micrometer-scale resolution imaging of the anterior eye in vivo with optical coherence tomography. Arch Ophthalmol 1994;112:1584-1589.
    • (1994) Arch Ophthalmol , vol.112 , pp. 1584-1589
    • Izatt, J.A.1    Hee, M.R.2    Swanson, E.A.3
  • 4
    • 0036156562 scopus 로고    scopus 로고
    • Repeatability and reproducibility of macular thickness measurements with the Humphrey OCT system
    • Muscat S, Parks S, Kemp E, et al. Repeatability and reproducibility of macular thickness measurements with the Humphrey OCT system. Invest Ophthalmol Vis Sci 2002;43:490-495.
    • (2002) Invest Ophthalmol Vis Sci , vol.43 , pp. 490-495
    • Muscat, S.1    Parks, S.2    Kemp, E.3
  • 5
    • 0036295281 scopus 로고    scopus 로고
    • Relation between optical coherence tomography and optical pachymetry measurements of corneal swelling induced by hypoxia
    • Wang J, Fonn D, Simpson TL, et al. Relation between optical coherence tomography and optical pachymetry measurements of corneal swelling induced by hypoxia. Am J Ophthalmol 2002;134:93-98.
    • (2002) Am J Ophthalmol , vol.134 , pp. 93-98
    • Wang, J.1    Fonn, D.2    Simpson, T.L.3
  • 6
    • 33748119532 scopus 로고    scopus 로고
    • Repeated measurements of dynamic tear distribution on the ocular surface after instillation of artificial tears
    • Wang J, Aquavella J, Palakuru J, et al. Repeated measurements of dynamic tear distribution on the ocular surface after instillation of artificial tears. Invest Ophthalmol Vis Sci 2006;47:3325-3329.
    • (2006) Invest Ophthalmol Vis Sci , vol.47 , pp. 3325-3329
    • Wang, J.1    Aquavella, J.2    Palakuru, J.3
  • 7
    • 34547907003 scopus 로고    scopus 로고
    • In vivo corneal highspeed, ultra high-resolution optical coherence tomography
    • Christopoulos V, Kagemann L, Wollstein G, et al. In vivo corneal highspeed, ultra high-resolution optical coherence tomography. Arch Ophthalmol 2007;125:1027-1035.
    • (2007) Arch Ophthalmol , vol.125 , pp. 1027-1035
    • Christopoulos, V.1    Kagemann, L.2    Wollstein, G.3
  • 8
    • 34248525108 scopus 로고    scopus 로고
    • Visualization of aqueous shunt position and patency using anterior segment optical coherence tomography
    • Sarodia U, Sharkawi E, Hau S, et al. Visualization of aqueous shunt position and patency using anterior segment optical coherence tomography. Am J Ophthalmol 2007;143:1054-1056.
    • (2007) Am J Ophthalmol , vol.143 , pp. 1054-1056
    • Sarodia, U.1    Sharkawi, E.2    Hau, S.3
  • 10
    • 37349104877 scopus 로고    scopus 로고
    • Spectral optical coherence tomography in video-rate and 3D imaging of contact lens wear
    • Kaluzny BJ, Fojt W, Szkulmowska A, et al. Spectral optical coherence tomography in video-rate and 3D imaging of contact lens wear. Optom Vis Sci 2007;84:1104-1109.
    • (2007) Optom Vis Sci , vol.84 , pp. 1104-1109
    • Kaluzny, B.J.1    Fojt, W.2    Szkulmowska, A.3
  • 11
    • 33645125472 scopus 로고    scopus 로고
    • Spectral optical coherence tomography: A new imaging technique in contact lens practice
    • Kaluzny BJ, Kaluzny JJ, Szkulmowska A, et al. Spectral optical coherence tomography: A new imaging technique in contact lens practice. Ophthalmic Physiol Opt 2006;26:127-132.
    • (2006) Ophthalmic Physiol Opt , vol.26 , pp. 127-132
    • Kaluzny, B.J.1    Kaluzny, J.J.2    Szkulmowska, A.3
  • 12
    • 15044358722 scopus 로고    scopus 로고
    • Is fluorescein pattern analysis a valid method of assessing the accuracy of reverse geometry lenses for orthok-eratology?
    • Mountford J, Cho P, Chui WS. Is fluorescein pattern analysis a valid method of assessing the accuracy of reverse geometry lenses for orthok-eratology? Clin Exp Optom 2005;88:33-38.
    • (2005) Clin Exp Optom , vol.88 , pp. 33-38
    • Mountford, J.1    Cho, P.2    Chui, W.S.3
  • 13
    • 0038204057 scopus 로고    scopus 로고
    • Correction of geometric and refractive image distortions in optical coherence tomography applying Fermat's principle
    • Westphal V, Rollins A, Radhakrishnan S, et al. Correction of geometric and refractive image distortions in optical coherence tomography applying Fermat's principle. Opt Express 2002;10:397-404.
    • (2002) Opt Express , vol.10 , pp. 397-404
    • Westphal, V.1    Rollins, A.2    Radhakrishnan, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.