메뉴 건너뛰기




Volumn , Issue , 2007, Pages 211-214

Novel QRS detection by CWT for ECG sensor

Author keywords

[No Author keywords available]

Indexed keywords

BASELINE DRIFT; COMMON SENSE; CONTINUOUS WAVELET TRANSFORM; CONTINUOUS WAVELET TRANSFORMS; DETECTION RATES; DIFFERENTIATORS; ECG SENSORS; EXISTING METHOD; FIRST-ORDER DERIVATIVE; MODULUS MAXIMA; NOVEL ALGORITHM; QRS DETECTION; ZERO CROSSING POINTS; ZERO-CROSSINGS;

EID: 68449092260     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/BIOCAS.2007.4463346     Document Type: Conference Paper
Times cited : (24)

References (20)
  • 1
    • 0028960610 scopus 로고
    • Detection of ECG characteristic points using wavelet transforms
    • Jan.
    • C. Li, C. Zheng, and C. Tai, "Detection of ECG characteristic points using wavelet transforms," IEEE Trans. Biomed. Eng., vol. 42, pp. 21-28, Jan. 1995.
    • (1995) IEEE Trans. Biomed. Eng. , vol.42 , pp. 21-28
    • Li, C.1    Zheng, C.2    Tai, C.3
  • 2
    • 12144285744 scopus 로고    scopus 로고
    • A wavelet-based ECG delineator: Evaluation on standard databases
    • Apr.
    • J.P. Martinez, R. Almeida, S. Olmos, A.P. Rocha, and P. Laguna, "A wavelet-based ECG delineator: evaluation on standard databases," IEEE Trans. Biomed. Eng., vol. 51, No 4, pp.570-581, Apr. 2004.
    • (2004) IEEE Trans. Biomed. Eng. , vol.51 , Issue.4 , pp. 570-581
    • Martinez, J.P.1    Almeida, R.2    Olmos, S.3    Rocha, A.P.4    Laguna, P.5
  • 5
    • 0031023185 scopus 로고    scopus 로고
    • DSP implementation of wavelet transform for real time ECG wave forms detection and heart rate analysis
    • Jan.
    • M. Bahoura, M. Hassani, and M. Hubin, "DSP implementation of wavelet transform for real time ECG wave forms detection and heart rate analysis," Computer Methods and Programs in Biomedicine, vol. 52, pp.35-44, Jan. 1997.
    • (1997) Computer Methods and Programs in Biomedicine , vol.52 , pp. 35-44
    • Bahoura, M.1    Hassani, M.2    Hubin, M.3
  • 6
    • 0037145626 scopus 로고    scopus 로고
    • Feature extraction from ECG signals using wavelet transforms for disease diagnostics
    • Jul.
    • S. C. Saxena, V. Kumar, and S.T. Hamde, "Feature extraction from ECG signals using wavelet transforms for disease diagnostics," International Journal of System Science, vol. 33, pp.1073-1085, Jul. 2002.
    • (2002) International Journal of System Science , vol.33 , pp. 1073-1085
    • Saxena, S.C.1    Kumar, V.2    Hamde, S.T.3
  • 8
    • 33744914300 scopus 로고    scopus 로고
    • A real time QRS detection method based on moving-averaging incorporating with wavelet denosing
    • May
    • S. Chen, H Chen, and H. Chan, "A real time QRS detection method based on moving-averaging incorporating with wavelet denosing," Computer Methods and Programs in Biomedicine, vol. 82, pp.187-195, May 2006.
    • (2006) Computer Methods and Programs in Biomedicine , vol.82 , pp. 187-195
    • Chen, S.1    Chen, H.2    Chan, H.3
  • 9
    • 0343807459 scopus 로고    scopus 로고
    • Evaluation of a wavelet-based ECG waveform detector on the QT database
    • Sept.
    • J.P. Martinez, S. Olmos, and P. Laguna, "Evaluation of a wavelet-based ECG waveform detector on the QT database," IEEE Computers in Cardiology, vol. 27, pp. 81-84, Sept. 2000.
    • (2000) IEEE Computers in Cardiology , vol.27 , pp. 81-84
    • Martinez, J.P.1    Olmos, S.2    Laguna, P.3
  • 11
    • 77956362912 scopus 로고    scopus 로고
    • Available
    • Available: http://www.physionet.org/physiobank/database/mitdb/
  • 13
    • 0029394907 scopus 로고
    • Genetic design of optimum linear and nolinear QRS detectors
    • Nov.
    • R. Poli, S. Cagnoni, and G. Valli, "Genetic Design of optimum linear and nolinear QRS Detectors," IEEE Trans. Biomed. Eng., vol. 42, pp.1137-1141, Nov. 1995.
    • (1995) IEEE Trans. Biomed. Eng. , vol.42 , pp. 1137-1141
    • Poli, R.1    Cagnoni, S.2    Valli, G.3
  • 14
    • 0021892137 scopus 로고
    • A real time QRS detection algorithm
    • Mar.
    • J. Pan and W.J. Tompkins, "A real time QRS detection algorithm," IEEE Trans. Biomed. Eng., vol. 32, pp.230-236, Mar. 1985
    • (1985) IEEE Trans. Biomed. Eng. , vol.32 , pp. 230-236
    • Pan, J.1    Tompkins, W.J.2
  • 16
    • 0022929617 scopus 로고
    • Quantitative investigation of QRS detection rules using the MIT/BIH arrhythmia database
    • Mar.
    • P.S. Hamilton, and W.J. Tompkins, "Quantitative investigation of QRS detection rules using the MIT/BIH arrhythmia database," IEEE Trans. Biomed. Eng., vol. 33, pp.1157-1165, Mar. 1986.
    • (1986) IEEE Trans. Biomed. Eng. , vol.33 , pp. 1157-1165
    • Hamilton, P.S.1    Tompkins, W.J.2
  • 17
    • 0026848861 scopus 로고
    • Neural-network-based adaptive filtering for QRS detection
    • Apr.
    • Q Xue, Y.H. Hu, and W.J. Tompkins, "Neural-network-based adaptive filtering for QRS detection," IEEE Trans. Biomed. Eng., vol. 39, pp.315-329, Apr. 1992.
    • (1992) IEEE Trans. Biomed. Eng. , vol.39 , pp. 315-329
    • Xue, Q.1    Hu, Y.H.2    Tompkins, W.J.3
  • 18
    • 0031106763 scopus 로고    scopus 로고
    • A real-time microprocessor QRS detector system with a 1-ms tiing acauracy for the measurement of ambulatory HRV
    • Feb.
    • A. Ruha, S. Sallinen, and S. Nissila, "A real-time microprocessor QRS detector system with a 1-ms tiing acauracy for the measurement of ambulatory HRV", IEEE Trans. Biomed. Eng., vol. 44, pp.159-167, Feb. 1997.
    • (1997) IEEE Trans. Biomed. Eng. , vol.44 , pp. 159-167
    • Ruha, A.1    Sallinen, S.2    Nissila, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.