메뉴 건너뛰기




Volumn 32, Issue 2, 2009, Pages 501-512

Two-phase spray cooling of hybrid vehicle electronics

Author keywords

Boiling; Critical heat flux (CHF); Dielectric coolant; Hybrid vehicles; Phase change; Power electronics; Refrigerant; Sprays

Indexed keywords

BOILING; CRITICAL HEAT FLUX (CHF); DIELECTRIC COOLANT; HYBRID VEHICLES; PHASE CHANGE; SPRAYS;

EID: 68349141289     PISSN: 15213331     EISSN: None     Source Type: Journal    
DOI: 10.1109/TCAPT.2008.2006907     Document Type: Article
Times cited : (156)

References (14)
  • 1
    • 68349152285 scopus 로고    scopus 로고
    • Electrical and electronics technical team roadmap, Electrical and Electronics Technical Team, U.S. Dept. of Energy, Washington, DC, 2006.
    • "Electrical and electronics technical team roadmap," Electrical and Electronics Technical Team, U.S. Dept. of Energy, Washington, DC, 2006.
  • 3
    • 0035363424 scopus 로고    scopus 로고
    • Assessment of high-heat-flux thermal management schemes
    • Jun
    • I. Mudawar, "Assessment of high-heat-flux thermal management schemes," IEEE Trans. Compon. Packag. Technol., vol. 24, no. 2, pp. 122-141, Jun. 2001.
    • (2001) IEEE Trans. Compon. Packag. Technol , vol.24 , Issue.2 , pp. 122-141
    • Mudawar, I.1
  • 4
    • 0000203275 scopus 로고
    • A study in mist cooling (1st report: Investigation of mist cooling)
    • S. Toda, "A study in mist cooling (1st report: Investigation of mist cooling)," Trans. JSME, vol. 38, pp. 581-588, 1972.
    • (1972) Trans. JSME , vol.38 , pp. 581-588
    • Toda, S.1
  • 5
    • 32144432060 scopus 로고
    • Critical heat flux in saturated forced convection boiling with an impinging droplet
    • M. Monde, "Critical heat flux in saturated forced convection boiling with an impinging droplet," Trans. JSME, vol. 46, pp. 1146-1155, 1980.
    • (1980) Trans. JSME , vol.46 , pp. 1146-1155
    • Monde, M.1
  • 6
    • 0024121942 scopus 로고
    • Comparison of burnout characteristics in jet impingement cooling and spray cooling
    • Houston, TX
    • C. S. K. Cho and K. Wu, "Comparison of burnout characteristics in jet impingement cooling and spray cooling," in Proc. Nat. Heat Transfer Conf., Houston, TX, 1988, pp. 561-567.
    • (1988) Proc. Nat. Heat Transfer Conf , pp. 561-567
    • Cho, C.S.K.1    Wu, K.2
  • 7
    • 0000787148 scopus 로고
    • Determination of the local quench curve for spray-cooled metallic surfaces
    • I. Mudawar and W. S. Valentine, "Determination of the local quench curve for spray-cooled metallic surfaces," J. Heat Treating, vol. 7, pp. 107-121, 1989.
    • (1989) J. Heat Treating , vol.7 , pp. 107-121
    • Mudawar, I.1    Valentine, W.S.2
  • 8
    • 0029395132 scopus 로고
    • Correlation of Sauter mean diameter and critical heat flux for spray cooling of small surfaces
    • K. A. Estes and I. Mudawar, "Correlation of Sauter mean diameter and critical heat flux for spray cooling of small surfaces," Int. J. Heat Mass Transfer, vol. 38, pp. 2985-2996, 1995.
    • (1995) Int. J. Heat Mass Transfer , vol.38 , pp. 2985-2996
    • Estes, K.A.1    Mudawar, I.2
  • 9
    • 0036642336 scopus 로고    scopus 로고
    • Effects of spray characteristics on critical heat flux in subcooled water spray cooling
    • R.-H. Chen, L. C. Chow, and J. E. Navedo, "Effects of spray characteristics on critical heat flux in subcooled water spray cooling," Int. J. Heat Mass Transfer, vol. 45, pp. 4033-4043, 2002.
    • (2002) Int. J. Heat Mass Transfer , vol.45 , pp. 4033-4043
    • Chen, R.-H.1    Chow, L.C.2    Navedo, J.E.3
  • 10
    • 0029294256 scopus 로고
    • Experimental and numerical study of quenching complex-shaped metallic alloys with multiple, overlapping sprays
    • D. D. Hall and I. Mudawar, "Experimental and numerical study of quenching complex-shaped metallic alloys with multiple, overlapping sprays," Int. J. Heat Mass Transfer, vol. 38, pp. 1201-1216, 1995.
    • (1995) Int. J. Heat Mass Transfer , vol.38 , pp. 1201-1216
    • Hall, D.D.1    Mudawar, I.2
  • 11
    • 50949101990 scopus 로고    scopus 로고
    • Subcontract report to the National Renewable Energy Laboratory, West Lafayette, IN
    • I. Mudawar, "Spray cooling of power electronics," Subcontract report to the National Renewable Energy Laboratory, West Lafayette, IN, 2006.
    • (2006) Spray cooling of power electronics
    • Mudawar, I.1
  • 12
    • 0027293613 scopus 로고
    • The fourth meeting of the parties to the Montreal Protocol: Report and reflection
    • I. H. Rowlands, "The fourth meeting of the parties to the Montreal Protocol: Report and reflection," Environment, vol. 35, pp. 25-34, 1993.
    • (1993) Environment , vol.35 , pp. 25-34
    • Rowlands, I.H.1
  • 13
    • 0000610418 scopus 로고    scopus 로고
    • Optimizing and predicting CHF in spray cooling of a square surface
    • I. Mudawar and K. A. Estes, "Optimizing and predicting CHF in spray cooling of a square surface," J. Heat Transfer, vol. 118, pp. 672-680, 1996.
    • (1996) J. Heat Transfer , vol.118 , pp. 672-680
    • Mudawar, I.1    Estes, K.A.2
  • 14
    • 32144440510 scopus 로고    scopus 로고
    • Single-phase and two-phase cooling characteristics of upward-facing and downward-facing sprays
    • J. R. Rybicki and I. Mudawar, "Single-phase and two-phase cooling characteristics of upward-facing and downward-facing sprays," Int. J. Heat Mass Transfer, vol. 49, pp. 5-12, 2006.
    • (2006) Int. J. Heat Mass Transfer , vol.49 , pp. 5-12
    • Rybicki, J.R.1    Mudawar, I.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.