메뉴 건너뛰기




Volumn 42, Issue 6, 2009, Pages 870-880

Determination of pseudoephedrine hydrochloride in some pharmaceutical drugs by potentiometric membrane sensor based on pseudoephedrine-phosphotungstate ion pair

Author keywords

Ion pair sensor; Potentiometry; Pseudoephedrine hydrochloride; PVC membrane; Selectivity

Indexed keywords


EID: 68349121660     PISSN: 00032719     EISSN: 1532236X     Source Type: Journal    
DOI: 10.1080/00032710902722079     Document Type: Article
Times cited : (19)

References (21)
  • 1
    • 0034327168 scopus 로고    scopus 로고
    • Cetylpyridinium-iodomercurate PVC membrane ion selective electrode for the determination of cetylpyridinium cation in Ezafluor mouth wash and as a detector for some potentiometric titrations
    • Abbas, M.N., Mostafa, G.A.E., and Homoda, A.M.A. 2000. Cetylpyridinium-iodomercurate PVC membrane ion selective electrode for the determination of cetylpyridinium cation in Ezafluor mouth wash and as a detector for some potentiometric titrations. Talanta, 53: 425-432.
    • (2000) Talanta , vol.53 , pp. 425-432
    • Abbas, M.N.1    Mostafa, G.A.E.2    Homoda, A.M.A.3
  • 2
    • 0035855958 scopus 로고    scopus 로고
    • PVC membrane ion selective electrode for the determination of pentachlorophenol in water, wood, and soil using tetrazolium pentachlorophenolate
    • Abbas, M.N., Mostafa, G.A.E., and Homoda, A.M.A. 2001. PVC membrane ion selective electrode for the determination of pentachlorophenol in water, wood, and soil using tetrazolium pentachlorophenolate. Talanta, 55: 647-656.
    • (2001) Talanta , vol.55 , pp. 647-656
    • Abbas, M.N.1    Mostafa, G.A.E.2    Homoda, A.M.A.3
  • 3
    • 18444400270 scopus 로고    scopus 로고
    • Ion selective PVC membrane electrode for the determination of methacycline hydrochloride in pharmaceutical formulation
    • Aboul-Enein, H.Y., Sun, X.X., and Sun, C.J. 2002. Ion selective PVC membrane electrode for the determination of methacycline hydrochloride in pharmaceutical formulation. Sensors, 2: 424-431.
    • (2002) Sensors , vol.2 , pp. 424-431
    • Aboul-Enein, H.Y.1    Sun, X.X.2    Sun, C.J.3
  • 5
    • 0022980955 scopus 로고
    • Ion-selective electrode for the determination of metoclopramide
    • Badawy, S.S., Shoukry, A.F., and Issa, Y.M. 1986. Ion-selective electrode for the determination of metoclopramide. Analyst, 111: 1363-1365.
    • (1986) Analyst , vol.111 , pp. 1363-1365
    • Badawy, S.S.1    Shoukry, A.F.2    Issa, Y.M.3
  • 6
    • 4544366331 scopus 로고    scopus 로고
    • Carrier-based ion-selective electrodes and bulk optodes, 1: General characteristics
    • Bakker, E., Buhlmann, P., and Pretsch, E. 1997. Carrier-based ion-selective electrodes and bulk optodes, 1: General characteristics. Chem. Rev. 97: 3083-3132.
    • (1997) Chem. Rev , vol.97 , pp. 3083-3132
    • Bakker, E.1    Buhlmann, P.2    Pretsch, E.3
  • 8
    • 84973049265 scopus 로고
    • Recent advances in pharmaceutical analysis with potentiometric membrane sensors
    • Cosofre, V.V. and Buck, R.P. 1993. Recent advances in pharmaceutical analysis with potentiometric membrane sensors. Crit. Rev. Anal. Chem. 24: 1-58.
    • (1993) Crit. Rev. Anal. Chem , vol.24 , pp. 1-58
    • Cosofre, V.V.1    Buck, R.P.2
  • 9
    • 17844399370 scopus 로고
    • Determination of selectivity coefficients of ion-selective electrodes by a matched-potential method
    • Gadzepko, V.P.Y. and Christion, G.D. 1984. Determination of selectivity coefficients of ion-selective electrodes by a matched-potential method. Anal. Chim. Acta, 164: 279-282.
    • (1984) Anal. Chim. Acta , vol.164 , pp. 279-282
    • Gadzepko, V.P.Y.1    Christion, G.D.2
  • 10
    • 32644455343 scopus 로고
    • Cryptate formation in non-aqueous solvents: New aspects in single-ion thermodynamics
    • Gutknecht, J., Schneider, H., and Stroka, J. 1978. Cryptate formation in non-aqueous solvents: New aspects in single-ion thermodynamics. Inorg. Chem. 17: 3326-3329.
    • (1978) Inorg. Chem , vol.17 , pp. 3326-3329
    • Gutknecht, J.1    Schneider, H.2    Stroka, J.3
  • 11
    • 0030353029 scopus 로고    scopus 로고
    • Hydrogen chromate PVC matrix membrane sensor for potentiometric determination of chromium(III) and chromium(VI) ions
    • Hassan, S.S.M., Abbas, M.N., and Mostafa, G.A.E. 1996. Hydrogen chromate PVC matrix membrane sensor for potentiometric determination of chromium(III) and chromium(VI) ions. Talanta, 43: 797-804.
    • (1996) Talanta , vol.43 , pp. 797-804
    • Hassan, S.S.M.1    Abbas, M.N.2    Mostafa, G.A.E.3
  • 12
    • 0031900017 scopus 로고    scopus 로고
    • Flow injection potentiometric determination of atrazine in herbicide formulations
    • Hassan, S.S.M., Abbas, M.N., and Mostafa, G.A.E. 1998. Flow injection potentiometric determination of atrazine in herbicide formulations. Anal. Lett. 31: 777-791.
    • (1998) Anal. Lett , vol.31 , pp. 777-791
    • Hassan, S.S.M.1    Abbas, M.N.2    Mostafa, G.A.E.3
  • 13
    • 0034224826 scopus 로고    scopus 로고
    • Molecularly imprinted polymers and their use in biomimetic sensors
    • Haupt, K. and Mosbach, K. 2000. Molecularly imprinted polymers and their use in biomimetic sensors. Chem. Rev. 100: 2495.
    • (2000) Chem. Rev , vol.100 , pp. 2495
    • Haupt, K.1    Mosbach, K.2
  • 14
    • 0037026361 scopus 로고    scopus 로고
    • Polymeric membrane ion-selective electrode for determination of bismuth(III) in pharmaceutical substances
    • Kharitonov, S.V. 2002. Polymeric membrane ion-selective electrode for determination of bismuth(III) in pharmaceutical substances. J. Pharm. Bio. Anal. 30: 181-187.
    • (2002) J. Pharm. Bio. Anal , vol.30 , pp. 181-187
    • Kharitonov, S.V.1
  • 15
    • 29144444340 scopus 로고    scopus 로고
    • Preparation of a novel iodide-selective electrode based on iodide-miconazole ion pair and its application to pharmaceutical analysis
    • Jalali, F., Rajabi, M., Bahrami, G., and Shamsipur, M. 2005. Preparation of a novel iodide-selective electrode based on iodide-miconazole ion pair and its application to pharmaceutical analysis. Anal. Sci. 21: 1533-1535.
    • (2005) Anal. Sci , vol.21 , pp. 1533-1535
    • Jalali, F.1    Rajabi, M.2    Bahrami, G.3    Shamsipur, M.4
  • 16
    • 0021816461 scopus 로고
    • Lidocaine-selective membrane electrodes and their applications in pharmaceutical analysis
    • Lonescu, M.S., Abrutis, A.A., Radulescu, N., Baiulescu, G.E., and Cosofre, V.V. 1985. Lidocaine-selective membrane electrodes and their applications in pharmaceutical analysis. Analyst, 110: 929-931.
    • (1985) Analyst , vol.110 , pp. 929-931
    • Lonescu, M.S.1    Abrutis, A.A.2    Radulescu, N.3    Baiulescu, G.E.4    Cosofre, V.V.5
  • 18
    • 0002697789 scopus 로고    scopus 로고
    • Application of zeolite-polydimethylsiloxane electrodes to potentiometric studies of cationic species
    • Matysik, S., Matysik, F.M., Mattusch, J., and Einicke, W.D. 1998. Application of zeolite-polydimethylsiloxane electrodes to potentiometric studies of cationic species. Electroanalysis, 10: 98-102.
    • (1998) Electroanalysis , vol.10 , pp. 98-102
    • Matysik, S.1    Matysik, F.M.2    Mattusch, J.3    Einicke, W.D.4
  • 19
    • 0034798366 scopus 로고    scopus 로고
    • PVC matrix membrane sensor for potentiometric determination of cetylpyridinium chloride
    • Mostafa, G.A.E. 2001. PVC matrix membrane sensor for potentiometric determination of cetylpyridinium chloride. Anal. Sci. 17: 1043-1047.
    • (2001) Anal. Sci , vol.17 , pp. 1043-1047
    • Mostafa, G.A.E.1
  • 20
    • 0036947984 scopus 로고    scopus 로고
    • Potentiometric PVC membrane sensor for the determination of scopolamine in some pharmaceutical formulations
    • Mostafa, G.A.E. 2002. Potentiometric PVC membrane sensor for the determination of scopolamine in some pharmaceutical formulations. Anal. Sci. 18: 1335-1339.
    • (2002) Anal. Sci , vol.18 , pp. 1335-1339
    • Mostafa, G.A.E.1
  • 21
    • 0033852799 scopus 로고    scopus 로고
    • Preparation of a ketoconazole ion-selective electrode and its application to pharmaceutical analysis
    • Shamsipur, M., and Jalali, F. 2000. Preparation of a ketoconazole ion-selective electrode and its application to pharmaceutical analysis. Anal. Sci. 16: 549-552.
    • (2000) Anal. Sci , vol.16 , pp. 549-552
    • Shamsipur, M.1    Jalali, F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.