메뉴 건너뛰기




Volumn 122, Issue 8, 2009, Pages 955-959

Accuracy and repeatability of direct ciliary sulcus diameter measurements by full-scale 50-megahertz ultrasound biomicroscopy

Author keywords

Accuracy; Ciliary sulcus diameter; Repeatability and reproducibility; Ultrasound biomicroscopy

Indexed keywords

ACCURACY; ADULT; ANTERIOR EYE CHAMBER ANGLE; ARTICLE; BIOMICROSCOPY; CILIARY DISK; CILIARY SULCUS DIAMETER; CONTROLLED STUDY; FEMALE; HUMAN; HUMAN TISSUE; MALE; MEASUREMENT ERROR; NORMAL HUMAN; OBSERVER VARIATION; OPTOMETRY; PHAKIC INTRAOCULAR LENS; POSTERIOR EYE CHAMBER; RELIABILITY; REPRODUCIBILITY; VISUAL SYSTEM PARAMETERS;

EID: 68249145915     PISSN: 03666999     EISSN: None     Source Type: Journal    
DOI: 10.3760/cma.j.issn.0366-6999.2009.08.015     Document Type: Article
Times cited : (14)

References (21)
  • 1
    • 0032770088 scopus 로고    scopus 로고
    • Posterior chamber collamer phakic intraocular lens for myopia and hyperopia
    • Pesando PM, Ghiringhello MP, Tagliavacche P. Posterior chamber collamer phakic intraocular lens for myopia and hyperopia. J Refract Surg 1999; 15: 415-423.
    • (1999) J Refract Surg , vol.15 , pp. 415-423
    • Pesando, P.M.1    Ghiringhello, M.P.2    Tagliavacche, P.3
  • 3
    • 34548226462 scopus 로고    scopus 로고
    • Direct Measurement of the ciliary sulcus diameter by 35-Megahertz Ultrasound Biomicroscopy
    • Oh J, Shin HH, Kim JH, Kim HM, Song JS. Direct Measurement of the ciliary sulcus diameter by 35-Megahertz Ultrasound Biomicroscopy. Ophthalmology 2007; 114: 1685-1688.
    • (2007) Ophthalmology , vol.114 , pp. 1685-1688
    • Oh, J.1    Shin, H.H.2    Kim, J.H.3    Kim, H.M.4    Song, J.S.5
  • 4
    • 0038102616 scopus 로고    scopus 로고
    • Implantable contact lens for moderate to high myopia: Relationship of vaulting to cataract formation
    • Gonvers M, Bornet C, Othenin-Girard P. Implantable contact lens for moderate to high myopia: relationship of vaulting to cataract formation. J Cataract Refract Surg 2003; 29: 918-924.
    • (2003) J Cataract Refract Surg , vol.29 , pp. 918-924
    • Gonvers, M.1    Bornet, C.2    Othenin-Girard, P.3
  • 5
    • 0031763250 scopus 로고    scopus 로고
    • Cataract formation after posterior chamber phakic intraocular lens implantation
    • Trindade F, Pereira F. Cataract formation after posterior chamber phakic intraocular lens implantation. J Cataract Refract Surg 1998; 24: 1661-1663.
    • (1998) J Cataract Refract Surg , vol.24 , pp. 1661-1663
    • Trindade, F.1    Pereira, F.2
  • 6
    • 0032938481 scopus 로고    scopus 로고
    • Cataract development after implantation of the Staar Collamer posterior chamber phakic lens
    • Fink AM, Gore C, Rosen E. Cataract development after implantation of the Staar Collamer posterior chamber phakic lens. J Cataract Refract Surg 1999; 25: 278-282.
    • (1999) J Cataract Refract Surg , vol.25 , pp. 278-282
    • Fink, A.M.1    Gore, C.2    Rosen, E.3
  • 7
    • 0031840911 scopus 로고    scopus 로고
    • Staar Collamer posterior chamber phakicintraocular lens to correct myopia and hyperopia
    • Rosen E, Gore C. Staar Collamer posterior chamber phakicintraocular lens to correct myopia and hyperopia. J Cataract Refract Surg 1998; 24: 596-606.
    • (1998) J Cataract Refract Surg , vol.24 , pp. 596-606
    • Rosen, E.1    Gore, C.2
  • 8
    • 0034907871 scopus 로고    scopus 로고
    • Predicting sulcus size using Ocular measurement
    • Pop M, Payette Y, Mansour M. Predicting sulcus size using Ocular measurement. J Cataract Refract Surg 2001; 27: 1033-1038.
    • (2001) J Cataract Refract Surg , vol.27 , pp. 1033-1038
    • Pop, M.1    Payette, Y.2    Mansour, M.3
  • 9
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 10
    • 27144479245 scopus 로고    scopus 로고
    • Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry
    • Barkana Y, Gerber Y, Elbaz U, Schwartz S, Ken-Dror G, Avni I. Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry. J Cataract Refract Sur 2005; 31: 1729-1935.
    • (2005) J Cataract Refract Sur , vol.31 , pp. 1729-1935
    • Barkana, Y.1    Gerber, Y.2    Elbaz, U.3    Schwartz, S.4    Ken-Dror, G.5    Avni, I.6
  • 11
    • 34247109660 scopus 로고    scopus 로고
    • A method of measuring anterior chamber volume using the anterior segment optical coherence tomographer and specialized software
    • Wang N, Wang B, Zhai G, Lei K, Wang L, Congdon N. A method of measuring anterior chamber volume using the anterior segment optical coherence tomographer and specialized software. Am J Ophthalmol 2007; 143: 879-881.
    • (2007) Am J Ophthalmol , vol.143 , pp. 879-881
    • Wang, N.1    Wang, B.2    Zhai, G.3    Lei, K.4    Wang, L.5    Congdon, N.6
  • 12
    • 0042357063 scopus 로고    scopus 로고
    • Angle-supported phakic intraocular lenses in eyes with keratoconus and myopia
    • Leccisotti A, Fields SV. Angle-supported phakic intraocular lenses in eyes with keratoconus and myopia. J Cataract Re-fract Surg 2003; 29: 1530-1536.
    • (2003) J Cataract Re-fract Surg , vol.29 , pp. 1530-1536
    • Leccisotti, A.1    Fields, S.V.2
  • 13
    • 0036714547 scopus 로고    scopus 로고
    • Artisan phakic intraocular lens for myopia: Short-term results of a prospective, multicenter study
    • Maloney RK, Nguyen LH, John ME. Artisan phakic intraocular lens for myopia: short-term results of a prospective, multicenter study. Ophthalmology 2002; 109: 1631-1641.
    • (2002) Ophthalmology , vol.109 , pp. 1631-1641
    • Maloney, R.K.1    Nguyen, L.H.2    John, M.E.3
  • 14
    • 0037312362 scopus 로고    scopus 로고
    • Sanders DR, Vukich JA, Doney K, Gaston M, Implantable Contact Lens in Treatment of Myopia Study Group. U.S. Food and Drug Administration clinical trial of the implantable contact lens for moderate to high myopia. Ophthalmology 2003; 110: 255-266.
    • Sanders DR, Vukich JA, Doney K, Gaston M, Implantable Contact Lens in Treatment of Myopia Study Group. U.S. Food and Drug Administration clinical trial of the implantable contact lens for moderate to high myopia. Ophthalmology 2003; 110: 255-266.
  • 16
    • 0022930150 scopus 로고
    • Posterior chamber intraocular lenses in a series of 75 autopsy eyes. Part II: Postimplantationb loop configuration
    • Park SB, Brems RN, Parsons MR, Pfeffer BR, Isenberg RA, Langley KE, et al. Posterior chamber intraocular lenses in a series of 75 autopsy eyes. Part II: Postimplantationb loop configuration. J Cataract Refract Surg 1986; 12: 363-366.
    • (1986) J Cataract Refract Surg , vol.12 , pp. 363-366
    • Park, S.B.1    Brems, R.N.2    Parsons, M.R.3    Pfeffer, B.R.4    Isenberg, R.A.5    Langley, K.E.6
  • 18
    • 0025905302 scopus 로고
    • Ciliary sulcus anatomical dimensions
    • Davis RM, Campbell DM, Jacoby BG. Ciliary sulcus anatomical dimensions. Cornea 1991; 10: 244-248.
    • (1991) Cornea , vol.10 , pp. 244-248
    • Davis, R.M.1    Campbell, D.M.2    Jacoby, B.G.3
  • 19
    • 0030976739 scopus 로고    scopus 로고
    • Age-related changes of the ciliary sulcus: Implications for implanting sulcus-fixated lenses
    • Blum M, Tetz MR, Faller U, Volcker HE. Age-related changes of the ciliary sulcus: Implications for implanting sulcus-fixated lenses. J Cataract Refract Surg 1997; 23: 91-96.
    • (1997) J Cataract Refract Surg , vol.23 , pp. 91-96
    • Blum, M.1    Tetz, M.R.2    Faller, U.3    Volcker, H.E.4
  • 20
    • 0034907871 scopus 로고    scopus 로고
    • Predicting sulcus size using ocular measurements
    • Pop M, Payette Y, Mansour M. Predicting sulcus size using ocular measurements. J Cataract Refract Surg 2001; 27: 1033-1038.
    • (2001) J Cataract Refract Surg , vol.27 , pp. 1033-1038
    • Pop, M.1    Payette, Y.2    Mansour, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.