메뉴 건너뛰기




Volumn 56, Issue 7, 2009, Pages 1340-1351

Synthetic transmit beam technique in an aberrating environment

Author keywords

[No Author keywords available]

Indexed keywords

B-MODE IMAGES; BEAM PROFILES; COMPENSATION TECHNIQUES; FRAME RATE; HIGHER ORDER; IMAGE ARTIFACTS; IN-VITRO; IN-VIVO MEASUREMENT; LATERAL SHIFTS; MEASURING METHOD; PARALLEL BEAMFORMING; PARALLEL BEAMS; PERFORMANCE ASPECTS; SHIFT VARIANCE; STANDARD DEVIATION; SYNTHETIC TRANSMIT BEAMS; TISSUE MIMICKING PHANTOM; TRACKING ERRORS; TRACKING PERFORMANCE; ULTRASOUND IMAGING SYSTEMS;

EID: 68249133591     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/TUFFC.2009.1190     Document Type: Article
Times cited : (8)

References (19)
  • 1
    • 0036708275 scopus 로고    scopus 로고
    • Analysis of temporal requirements for myocardial tissue velocity imaging
    • sep
    • B. Lind, J. Nowak, J. Dorph, J. van der Linden, and L. A. Brodin, "Analysis of temporal requirements for myocardial tissue velocity imaging," Eur. J. Echocardiogr., vol. 3, no. 3, pp. 214-219, sep. 2002.
    • (2002) Eur. J. Echocardiogr , vol.3 , Issue.3 , pp. 214-219
    • Lind, B.1    Nowak, J.2    Dorph, J.3    van der Linden, J.4    Brodin, L.A.5
  • 2
    • 0021419747 scopus 로고
    • Explososcan: A parallel processing technique for high speed ultrasound imaging with linear phased arrays
    • Apr
    • D. P. Shattuck, M. D. Weinshenker, S. W. Smith, and O. T. von Ramm, "Explososcan: A parallel processing technique for high speed ultrasound imaging with linear phased arrays," J. Acoust. Soc. Am., vol. 75, no. 4, pp. 1273-1282, Apr. 1984.
    • (1984) J. Acoust. Soc. Am , vol.75 , Issue.4 , pp. 1273-1282
    • Shattuck, D.P.1    Weinshenker, M.D.2    Smith, S.W.3    von Ramm, O.T.4
  • 3
    • 0026128878 scopus 로고
    • High-speed ultrasound volumetric imaging system-Part ii: Parallel processing and image display
    • Mar
    • O. T. von Ramm, s. W. Smith, and H. G. Pavy, "High-speed ultrasound volumetric imaging system-Part ii: Parallel processing and image display," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 38, no. 2, pp. 109-115, Mar. 1991.
    • (1991) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.38 , Issue.2 , pp. 109-115
    • von Ramm, O.T.1    Smith, S.W.2    Pavy, H.G.3
  • 4
    • 33846324698 scopus 로고    scopus 로고
    • The impact of aberration on high frame rate cardiac B-mode imaging
    • Jan
    • T. Bjåstad, S. A. Aase, and H. Torp, "The impact of aberration on high frame rate cardiac B-mode imaging," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 54, no. 1, pp. 32-41, Jan. 2007.
    • (2007) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.54 , Issue.1 , pp. 32-41
    • Bjåstad, T.1    Aase, S.A.2    Torp, H.3
  • 7
    • 21644448418 scopus 로고
    • High resolution multiline ultrasonic beamformer,
    • U.S. Patent 4 644 795, Feb. 24
    • L. J. Augustine, "High resolution multiline ultrasonic beamformer," U.S. Patent 4 644 795, Feb. 24, 1987.
    • (1987)
    • Augustine, L.J.1
  • 8
    • 33846275922 scopus 로고    scopus 로고
    • Ultrasound multi-beam distortion correction system and method,
    • U.S. Patent 5 779 640, jul. 14
    • G. L. Holley and I. M. Guracar, "Ultrasound multi-beam distortion correction system and method," U.S. Patent 5 779 640, jul. 14, 1998.
    • (1998)
    • Holley, G.L.1    Guracar, I.M.2
  • 9
    • 33846294501 scopus 로고    scopus 로고
    • System and method for reduction of parallel beamforming artifacts,
    • U.S. Patent 6 447 452, sep. 10
    • D.-L. D. Liu, J. C. Lazenby, Z. Banjanin, and B. A. McDermot, "System and method for reduction of parallel beamforming artifacts," U.S. Patent 6 447 452, sep. 10, 2002.
    • (2002)
    • Liu, D.-L.D.1    Lazenby, J.C.2    Banjanin, Z.3    McDermot, B.A.4
  • 10
    • 33846272474 scopus 로고
    • Ultrasonic imaging system using line splicing and parallel receive beam formation,
    • U.S. Patent 5 462 057, oct. 31
    • T. J. Hunt, B. M. Herrick, K. K. Robertson, and J. M. Ziel, "Ultrasonic imaging system using line splicing and parallel receive beam formation," U.S. Patent 5 462 057, oct. 31, 1995.
    • (1995)
    • Hunt, T.J.1    Herrick, B.M.2    Robertson, K.K.3    Ziel, J.M.4
  • 11
    • 0004333359 scopus 로고
    • Method and apparatus for increasing the frame rate and resolution of a phased array imaging system,
    • U.S. Patent 5 318 033, Jun. 7
    • B. J. Savord, "Method and apparatus for increasing the frame rate and resolution of a phased array imaging system," U.S. Patent 5 318 033, Jun. 7, 1994.
    • (1994)
    • Savord, B.J.1
  • 14
    • 84889628047 scopus 로고    scopus 로고
    • Principles and diferent techniques for speckle tracking
    • Chichester, UK: Blackwell Publishing
    • J. D'hooge, "Principles and diferent techniques for speckle tracking," in Myocardial Imaging: Tissue Doppler and Speckle Tracking. Chichester, UK: Blackwell Publishing, 2007, pp. 17-25.
    • (2007) Myocardial Imaging: Tissue Doppler and Speckle Tracking , pp. 17-25
    • D'hooge, J.1
  • 15
    • 0026838720 scopus 로고
    • Calculation of pressure felds from arbitrarily shaped, apodized, and excited ultrasound transducers
    • Mar
    • J. A. Jensen and N. B. Svendsen, "Calculation of pressure felds from arbitrarily shaped, apodized, and excited ultrasound transducers," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 39, pp. 262-267, Mar. 1992.
    • (1992) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.39 , pp. 262-267
    • Jensen, J.A.1    Svendsen, N.B.2
  • 17
    • 0030968538 scopus 로고    scopus 로고
    • Measurements of ultrasonic pulse distortion produced by human chest wall
    • L. M. Hinkelman, T. L. Szabo, and R. C. Waag, "Measurements of ultrasonic pulse distortion produced by human chest wall," J. Acoust. Soc. Am., vol. 104, no. 4, pp. 2365-2373, 1997.
    • (1997) J. Acoust. Soc. Am , vol.104 , Issue.4 , pp. 2365-2373
    • Hinkelman, L.M.1    Szabo, T.L.2    Waag, R.C.3
  • 19
    • 6844220459 scopus 로고
    • Normal intra cardiac Doppler fows
    • amsterdam: churchill livingstone
    • J. Rinaldi and B. Diebold, "Normal intra cardiac Doppler fows," in Cardiac Ultrasound. amsterdam: churchill livingstone, 1993, pp. 141-153.
    • (1993) Cardiac Ultrasound , pp. 141-153
    • Rinaldi, J.1    Diebold, B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.