메뉴 건너뛰기




Volumn 55, Issue 12, 2008, Pages 2683-2691

20 MHz/40 MHz dual element transducers for high frequency harmonic imaging

Author keywords

[No Author keywords available]

Indexed keywords

3 DB BANDWIDTH; CENTER FREQUENCY; DUAL ELEMENT TRANSDUCERS; ELECTRICAL IMPEDANCE; FIELD II; HARMONIC IMAGING; HARMONIC SIGNALS; HIGH SENSITIVITY; HIGH-FREQUENCY HARMONICS; HUMAN EYE; LITHIUM NIOBATE; LOW DIELECTRIC CONSTANTS; MATCHING LAYER; OPHTHALMIC IMAGING; POSTERIOR SEGMENT; RING DIAMETER; RING ELEMENTS; SECOND HARMONIC SIGNALS; SECOND-HARMONIC IMAGING; SIMULATED RESULTS; SINGLE ELEMENT; SPATIAL RESOLUTION; TIME DOMAIN; WIDE BANDWIDTH;

EID: 68149119346     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/TUFFC.2008.983     Document Type: Article
Times cited : (32)

References (14)
  • 5
    • 33645669357 scopus 로고    scopus 로고
    • An ultrasonic transducer for second harmonic imaging using a LiNbO3 plate with a local ferroelectric inversion layer
    • K. Nakamura, K. Fukazawa, K. Yamada, and S. Saito, "an ultrasonic transducer for second harmonic imaging using a LiNbO3 plate with a local ferroelectric inversion layer", IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 53, no. 3, pp. 651-655, 2006.
    • (2006) IEEE Trans. Ultrason., Ferroelect., Freq. Contr. , vol.53 , Issue.3 , pp. 651-655
    • Nakamura, K.1    Fukazawa, K.2    Yamada, K.3    Saito, S.4
  • 6
    • 77955077049 scopus 로고    scopus 로고
    • Sonomed, Inc.: Lake Success, NY, Available
    • Ultrasound Biomicroscopy System VuMax-II Brochure. Sonomed, Inc.: Lake Success, NY, 2006. Available: http://www.sonomedinc.com/VuMaxpdf.
    • (2006) Ultrasound Biomicroscopy System VuMax-II Brochure
  • 8
    • 0036195532 scopus 로고    scopus 로고
    • Nonlinear acoustics in diagnostic ultrasound
    • F. A. Duck, "Nonlinear acoustics in diagnostic ultrasound", Ultrasound Med. Biol., vol. 28, pp. 1-18, 2002.
    • (2002) Ultrasound Med. Biol. , vol.28 , pp. 1-18
    • Duck, F.A.1
  • 9
    • 0442326648 scopus 로고    scopus 로고
    • Design of efcient, broadband single-element (20-80 MHz) ultrasonic transducers for medical imaging applications
    • J. M. Cannata, T. A. Ritter, W. H. Chen, R. H. Silverman, and K. K. Shung, "Design of efcient, broadband single-element (20-80 MHz) ultrasonic Transducers for Medical Imaging applications", IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 50, no. 11, pp. 1548-1557, 2003.
    • (2003) IEEE Trans. Ultrason., Ferroelect., Freq. Contr. , vol.50 , Issue.11 , pp. 1548-1557
    • Cannata, J.M.1    Ritter, T.A.2    Chen, W.H.3    Silverman, R.H.4    Shung, K.K.5
  • 10
    • 33845714777 scopus 로고    scopus 로고
    • Schlieren metrology for high frequency medical ultrasound
    • C. Zanelli and S. Howard, "Schlieren metrology for high frequency medical ultrasound", Ultrasonics, vol. 44, suppl. 1, pp. e105-e107, 2006.
    • (2006) Ultrasonics , vol.44 , Issue.1 SUPPL.
    • Zanelli, C.1    Howard, S.2
  • 13
    • 24044478820 scopus 로고    scopus 로고
    • Field: A program for simulating ultrasound systems
    • J. A. Jensen, "Field: A program for simulating ultrasound systems", Med. Biol. Eng. Comput., vol. 34, no. 1, pp. 351-353, 1996.
    • (1996) Med. Biol. Eng. Comput. , vol.34 , Issue.1 , pp. 351-353
    • Jensen, J.A.1
  • 14
    • 0033873480 scopus 로고    scopus 로고
    • Arc-scanning very high-frequency ultrasound for 3-D pachymetric mapping of the corneal epithelium and stroma in laser in situ keratomileusis
    • D. Z. Reinstein, R. H. Silverman, T. Raevsky, G. J. Simoni, H. O. Lloyd, D. J. Najaf, M. J. Rondeau, and D. J. Coleman, "Arc-scanning very high-frequency ultrasound for 3-D pachymetric mapping of the corneal epithelium and stroma in laser in situ keratomileusis", J. Refract. Surg., vol. 16, pp. 414-430, 2000.
    • (2000) J. Refract. Surg. , vol.16 , pp. 414-430
    • Reinstein, D.Z.1    Silverman, R.H.2    Raevsky, T.3    Simoni, G.J.4    Lloyd, H.O.5    Najaf, D.J.6    Rondeau, M.J.7    Coleman, D.J.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.