메뉴 건너뛰기




Volumn 35, Issue 2, 2009, Pages 82-89

Cannulation practice patterns in haemodialysis vascular access : Predictors for unsuccessful cannulation

Author keywords

Arteriovenous fistulae nursing; Cannulation related complications; Haemodialysis; Vascular access cannulation

Indexed keywords

ADULT; AGED; ARTERIOVENOUS SHUNT; ARTICLE; BLOOD VESSEL PROSTHESIS; CATHETERIZATION; COMPARATIVE STUDY; EQUIPMENT; FEMALE; HUMAN; INDWELLING CATHETER; INSTRUMENTATION; MALE; MEDICAL ERROR; METHODOLOGY; MIDDLE AGED; MULTIVARIATE ANALYSIS; NETHERLANDS; NURSING; PROSPECTIVE STUDY; REGRESSION ANALYSIS; RENAL REPLACEMENT THERAPY; RISK FACTOR; STATISTICS;

EID: 68049147214     PISSN: 17556678     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1755-6686.2009.00092.x     Document Type: Article
Times cited : (36)

References (17)
  • 1
    • 33644864490 scopus 로고    scopus 로고
    • Improving arteriovenous fistula cannulation skills
    • Ball L (2005). Improving arteriovenous fistula cannulation skills. Nephrology Nursing Journal 32, 611-617.
    • (2005) Nephrology Nursing Journal , vol.32 , pp. 611-617
    • Ball, L.1
  • 2
    • 39449085027 scopus 로고    scopus 로고
    • The native arteriovenous fistula in 2007. Research needs
    • Besarab A., Ravani P., Spergel L.M. et al. (2007). The native arteriovenous fistula in 2007. Research needs. Journal of Nephrology 20(6), 668-673.
    • (2007) Journal of Nephrology , vol.20 , Issue.6 , pp. 668-673
    • Besarab, A.1    Ravani, P.2    Spergel, L.M.3
  • 3
    • 0028881787 scopus 로고
    • Cannulation camp: Basic needle cannulation training for dialysis staff
    • Brouwer J. (1995). Cannulation camp: basic needle cannulation training for dialysis staff. Dialyses and Transplantation 24, 606-612.
    • (1995) Dialyses and Transplantation , vol.24 , pp. 606-612
    • Brouwer, J.1
  • 4
    • 20644434140 scopus 로고    scopus 로고
    • Needle placement is paramount to achieving effective dialysis and preserving vascular accesses
    • Brouwer D. (2005). Needle placement is paramount to achieving effective dialysis and preserving vascular accesses. Nursing Journal 32(2), 225-227.
    • (2005) Nursing Journal , vol.32 , Issue.2 , pp. 225-227
    • Brouwer, D.1
  • 5
    • 20644456254 scopus 로고    scopus 로고
    • Retrograde arterial needle placement improves dialysis adequacy
    • English DJ. (2005). Retrograde arterial needle placement improves dialysis adequacy. Nephrology Nursing Journal 32(2), 224.
    • (2005) Nephrology Nursing Journal , vol.32 , Issue.2 , pp. 224
    • English, D.J.1
  • 6
    • 0037213436 scopus 로고    scopus 로고
    • Creation, cannulation and survival of arterio-venous fistulae, data from the DOPPS
    • Hugh C, Rayner H.C., Pisoni R.L. et al. (2003). Creation, cannulation and survival of arterio-venous fistulae, data from the DOPPS. Kidney International 63, 323-330.
    • (2003) Kidney International , vol.63 , pp. 323-330
    • Hugh, C.1    Rayner, H.C.2    Pisoni, R.L.3
  • 7
    • 14544308469 scopus 로고    scopus 로고
    • Hemodialysis special interest group networking session: Improving vascular access cannulation skills
    • King, B. & Miller D. (2004). Hemodialysis special interest group networking session: improving vascular access cannulation skills. Nephrology Nursing Journal 31, 688.
    • (2004) Nephrology Nursing Journal , vol.31 , pp. 688
    • King, B.1    Miller, D.2
  • 8
    • 33646782630 scopus 로고    scopus 로고
    • Needle infiltration of arteriovenous fistulas in haemodialysis patients: Risk factors and consequences
    • Lee T., Barker J. & Allon M. (2006). Needle infiltration of arteriovenous fistulas in haemodialysis patients: risk factors and consequences. American Journal of Kidney Disease 47,1020-1026.
    • (2006) American Journal of Kidney Disease , vol.47 , pp. 1020-1026
    • Lee, T.1    Barker, J.2    Allon, M.3
  • 9
    • 44949245796 scopus 로고    scopus 로고
    • Buttonhole cannulation: Should this become the default technique for dialysis patients with native fistulas? Summary of the EDTNA/ERCA journal club discussion
    • Autumn
    • Murcutt G., Boogaerts M., Splidler B. et al. (2008). Buttonhole cannulation: should this become the default technique for dialysis patients with native fistulas? Summary of the EDTNA/ERCA journal club discussion, Autumn 2007. Journal of Renal Care 34(2), 101-108.
    • (2007) Journal of Renal Care 34(2) , pp. 101-108
    • Murcutt, G.1    Boogaerts, M.2    Splidler, B.3
  • 10
    • 33845807146 scopus 로고    scopus 로고
    • KDOQI clinical practice guidelines and clinical practice recommendations for 2006 updates: Vascular access
    • National Kidney Foundation
    • National Kidney Foundation. (2006). KDOQI clinical practice guidelines and clinical practice recommendations for 2006 updates: vascular access. American Journal of Kidney Disease 48(Suppl 1), S1-S322.
    • (2006) American Journal of Kidney Disease , vol.48 , Issue.SUPPL. 1
  • 12
    • 4544285583 scopus 로고    scopus 로고
    • Hemodialysis vascular access: How do practice patterns affect outcomes?
    • Pile C. (2004). Hemodialysis vascular access: how do practice patterns affect outcomes? Neprology Nursing Journal 31, 305-308.
    • (2004) Neprology Nursing Journal , vol.31 , pp. 305-308
    • Pile, C.1
  • 13
    • 0036787350 scopus 로고    scopus 로고
    • Hemodialysis arteriovenous fistula maturity: US evaluation
    • Robbin L, Chamberlain N., Lockhart M. et al. (2002). Hemodialysis arteriovenous fistula maturity: US evaluation. Radiology 225, 59-64.
    • (2002) Radiology , vol.225 , pp. 59-64
    • Robbin, L.1    Chamberlain, N.2    Lockhart, M.3
  • 14
    • 19044365299 scopus 로고    scopus 로고
    • Recommended standards for reports dealing with arteriovenous haemodialysis accesses
    • Sidawy A.N., Gray R., Besareb A. et al. (2002). Recommended standards for reports dealing with arteriovenous haemodialysis accesses. Journal of Vascular Surgery 35, 603-610.
    • (2002) Journal of Vascular Surgery , vol.35 , pp. 603-610
    • Sidawy, A.N.1    Gray, R.2    Besareb, A.3
  • 15
    • 37349120715 scopus 로고    scopus 로고
    • Clinically immature 6 arteriovenous hemodialysis fistulas: Effect of US on salvage
    • Singh P., Robbin Ml., Lockhart M.E. et al. (2008). Clinically immature 6 arteriovenous hemodialysis fistulas: effect of US on salvage. Radiology 246, 299-305.
    • (2008) Radiology , vol.246 , pp. 299-305
    • Singh, P.1    Robbin, M.2    Lockhart, M.E.3
  • 16
    • 0043195731 scopus 로고    scopus 로고
    • Management of the renal patient: Clinical algorithms on vascular access for haemodialysis
    • Tordoir J. & Mickley V. (2003). Management of the renal patient: clinical algorithms on vascular access for haemodialysis. EDTNA ERCA 29(3), 131-136.
    • (2003) EDTNA ERCA , vol.29 , Issue.3 , pp. 131-136
    • Tordoir, J.1    Mickley, V.2
  • 17
    • 3342894985 scopus 로고    scopus 로고
    • EDTNA/ERCA vascular access recommendations for nephrology nurses
    • & Research Board of EDTNA/ERCA
    • Van Waeleghem J.P., Elseviers M., De Vos J.Y. & Research Board of EDTNA/ERCA. (2004). EDTNA/ERCA vascular access recommendations for nephrology nurses. EDTNA/ERCA Journal 30(2), 97-105.
    • (2004) EDTNA/ERCA Journal , vol.30 , Issue.2 , pp. 97-105
    • Van Waeleghem, J.P.1    Elseviers, M.2    De Vos, J.Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.