메뉴 건너뛰기




Volumn 24, Issue 3, 2009, Pages 472.e1-472.e7

Lack of irrefutable validation does not negate clinical utility of near-infrared spectroscopy monitoring: Learning to trust new technology

Author keywords

Congenital heart disease; Near infrared spectroscopy; Pediatric critical care; Physician practice patterns; Technology

Indexed keywords

ARTICLE; CASE STUDY; CLINICAL ARTICLE; DETERIORATION; DEVICE; DIAGNOSTIC VALUE; EARLY DIAGNOSIS; HEART SURGERY; HUMAN; INFANT; MEDICAL TECHNOLOGY; NEAR INFRARED SPECTROSCOPY; NEWBORN; OUTCOME ASSESSMENT; OXYGEN SATURATION; PATIENT MONITORING; PEDIATRIC SURGERY; PHYSICIAN; POSTOPERATIVE CARE; RELIABILITY; RETROSPECTIVE STUDY; SURGICAL PATIENT; TISSUE OXYGENATION; VALIDATION PROCESS;

EID: 68049144712     PISSN: 08839441     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcrc.2008.05.004     Document Type: Article
Times cited : (23)

References (13)
  • 1
    • 0017571334 scopus 로고
    • Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters
    • Jöbsis F.F. Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters. Science 198 (1977) 1264-1267
    • (1977) Science , vol.198 , pp. 1264-1267
    • Jöbsis, F.F.1
  • 2
    • 37549059884 scopus 로고    scopus 로고
    • Progress of near-infrared spectroscopy and topography for brain and muscle clinical applications
    • Wolf M., Ferrari M., and Quaresima V. Progress of near-infrared spectroscopy and topography for brain and muscle clinical applications. J Biomed Opt 12 (2007) 062104
    • (2007) J Biomed Opt , vol.12 , pp. 062104
    • Wolf, M.1    Ferrari, M.2    Quaresima, V.3
  • 3
    • 19544386976 scopus 로고    scopus 로고
    • An NIRS matrix for detecting and correcting cerebral oxygen desaturation events during surgery and neuroendovascular procedures
    • Schwarz G., Litscher G., Delgado P.A., et al. An NIRS matrix for detecting and correcting cerebral oxygen desaturation events during surgery and neuroendovascular procedures. Neurol Res 27 (2005) 423-428
    • (2005) Neurol Res , vol.27 , pp. 423-428
    • Schwarz, G.1    Litscher, G.2    Delgado, P.A.3
  • 4
    • 34147154881 scopus 로고    scopus 로고
    • Near-infrared spectroscopy identifies compartment syndrome in an infant
    • Tobias J.D., and Hoernschemeyer D.G. Near-infrared spectroscopy identifies compartment syndrome in an infant. J Pediatr Orthop 27 (2007) 311-313
    • (2007) J Pediatr Orthop , vol.27 , pp. 311-313
    • Tobias, J.D.1    Hoernschemeyer, D.G.2
  • 5
    • 85058202262 scopus 로고    scopus 로고
    • Effect of volume resuscitation on systemic perfusion as detected by two-site near-infrared spectroscopy in dehydrated pediatric patients
    • Hanson S.J., Berens R.J., Hoffman G.M., et al. Effect of volume resuscitation on systemic perfusion as detected by two-site near-infrared spectroscopy in dehydrated pediatric patients. Anesthesiology 103 (2005) A1373
    • (2005) Anesthesiology , vol.103
    • Hanson, S.J.1    Berens, R.J.2    Hoffman, G.M.3
  • 7
    • 19444372909 scopus 로고    scopus 로고
    • Reproducibility of cerebral oxygenation measurement in neonates and infants in the clinical setting using the NIRO 300 oximeter
    • Dullenkopf A., Kolarova A., Schulz G., et al. Reproducibility of cerebral oxygenation measurement in neonates and infants in the clinical setting using the NIRO 300 oximeter. Pediatr Crit Care Med 6 (2005) 344-347
    • (2005) Pediatr Crit Care Med , vol.6 , pp. 344-347
    • Dullenkopf, A.1    Kolarova, A.2    Schulz, G.3
  • 8
    • 0028136523 scopus 로고
    • Bedside assessment of myocardial performance in the critically ill
    • Shephard J.N., Brecker S.J., and Evans T.W. Bedside assessment of myocardial performance in the critically ill. Intensive Care Med 20 (1994) 513-521
    • (1994) Intensive Care Med , vol.20 , pp. 513-521
    • Shephard, J.N.1    Brecker, S.J.2    Evans, T.W.3
  • 9
    • 0031150035 scopus 로고    scopus 로고
    • Information analysis and validation of intelligent monitoring systems in intensive care units
    • Moret-Bonillo V., Mosqueira-Rey E., and Alonso-Betanzos A. Information analysis and validation of intelligent monitoring systems in intensive care units. IEEE Trans Inf Technol Biomed 1 (1997) 87-99
    • (1997) IEEE Trans Inf Technol Biomed , vol.1 , pp. 87-99
    • Moret-Bonillo, V.1    Mosqueira-Rey, E.2    Alonso-Betanzos, A.3
  • 10
    • 10744227442 scopus 로고    scopus 로고
    • Changes in cerebral and somatic oxygenation during stage 1 palliation of hypoplastic left heart syndrome using continuous regional cerebral perfusion
    • Hoffman G.M., Stuth E.A., Jaquiss R.D., et al. Changes in cerebral and somatic oxygenation during stage 1 palliation of hypoplastic left heart syndrome using continuous regional cerebral perfusion. J Thorac Cardiovasc Surg 127 (2004) 223-233
    • (2004) J Thorac Cardiovasc Surg , vol.127 , pp. 223-233
    • Hoffman, G.M.1    Stuth, E.A.2    Jaquiss, R.D.3
  • 11
    • 33750364999 scopus 로고    scopus 로고
    • Assessment of the relationship between cerebral and splanchnic oxygen saturations measured by near-infrared spectroscopy and direct measurements of systemic haemodynamic variables and oxygen transport after the Norwood procedure
    • Li J., Van Arsdell G.S., Zhang G., et al. Assessment of the relationship between cerebral and splanchnic oxygen saturations measured by near-infrared spectroscopy and direct measurements of systemic haemodynamic variables and oxygen transport after the Norwood procedure. Heart 92 (2006) 1678-1685
    • (2006) Heart , vol.92 , pp. 1678-1685
    • Li, J.1    Van Arsdell, G.S.2    Zhang, G.3
  • 12
    • 85099525594 scopus 로고    scopus 로고
    • Validity of near-infrared cerebral spectroscopy
    • Pattinson K., Clutton-Brock T., and Imray C. Validity of near-infrared cerebral spectroscopy. Anaesthesia 59 (2004) 507-508
    • (2004) Anaesthesia , vol.59 , pp. 507-508
    • Pattinson, K.1    Clutton-Brock, T.2    Imray, C.3
  • 13
    • 33745932290 scopus 로고    scopus 로고
    • Physician factors as an indicatory of technological device adoption
    • Artis L.C., Burkhart T.M., Jorhnson T.J., et al. Physician factors as an indicatory of technological device adoption. J Med Syst 30 (2006) 177-186
    • (2006) J Med Syst , vol.30 , pp. 177-186
    • Artis, L.C.1    Burkhart, T.M.2    Jorhnson, T.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.