Volumn 22, Issue 4, 2009, Pages 393-399

Image retake analysis in digital radiography using DICOM header information

Author keywords

Diagnostic image quality; Digital Imaging and Communications in Medicine (DICOM); Image analysis

Indexed keywords

CHEST IMAGE; COMPUTED RADIOGRAPHY; DIAGNOSTIC IMAGE QUALITY; DIGITAL IMAGING; DIGITAL IMAGING AND COMMUNICATIONS IN MEDICINE (DICOM); DIGITAL IMAGING AND COMMUNICATIONS IN MEDICINES; DIGITAL RADIOGRAPHY; DIGITAL RADIOLOGY; IMAGE IDENTIFICATION; PATIENT DOSE; PATIENT IDENTIFICATION; POSITIONING ERROR; RADIOGRAPHIC TECHNIQUE; REJECT ANALYSIS; REPETITION RATE;

EID: 68049139324     PISSN: 08971889     EISSN: 1618727X     Source Type: Journal    
DOI: 10.1007/s10278-008-9135-y     Document Type: Article
Times cited : (41)

References (17)
  • 1
    • 0003431852 scopus 로고    scopus 로고
    • British Institute of Radiology. British Institute of Radiology London
    • British Institute of Radiology: Quality Assurance in the Diagnostic X-ray Department, London: British Institute of Radiology, 1998
    • (1998) Quality Assurance in the Diagnostic X-ray Department
  • 2
    • 0031886549 scopus 로고    scopus 로고
    • X-ray film reject analysis as a quality indicator
    • MA Dunn AT Roger 1998 X-ray film reject analysis as a quality indicator Radiography 4 29 31
    • (1998) Radiography , vol.4 , pp. 29-31
    • Dunn, M.A.1    Roger, A.T.2
  • 5
    • 0034808559 scopus 로고    scopus 로고
    • The challenge of governance: Achieving quality in diagnostic imaging
    • M Hardy A Persaud 2001 The challenge of governance: achieving quality in diagnostic imaging Radiography 7 159 163
    • (2001) Radiography , vol.7 , pp. 159-163
    • Hardy, M.1    Persaud, A.2
  • 8
    • 0026635670 scopus 로고
    • Quality assurance and radiologic audit
    • EM Pitcher PN Wells 1992 Quality assurance and radiologic audit Curr Opin Radiol 4 3 9 14
    • (1992) Curr Opin Radiol , vol.4 , Issue.3 , pp. 9-14
    • Pitcher, E.M.1    Wells, P.N.2
  • 9
    • 0029301132 scopus 로고
    • Quality control of storage phosphor digital radiography systems
    • M Freedman D Steller H Jafroudi SK Mun 1995 Quality control of storage phosphor digital radiography systems J Digit Imaging 8 2 67 74
    • (1995) J Digit Imaging , vol.8 , Issue.2 , pp. 67-74
    • Freedman, M.1    Steller, D.2    Jafroudi, H.3    Mun, S.K.4
  • 10
    • 19044395883 scopus 로고    scopus 로고
    • Is reject analysis necessary after converting to computed radiography?
    • R Honea ME Blado Y Ma 2002 Is reject analysis necessary after converting to computed radiography? J Digit Imaging 15 Suppl 1 41 52
    • (2002) J Digit Imaging , vol.15 , Issue.SUPPL 1 , pp. 41-52
    • Honea, R.1    Blado, M.E.2    Ma, Y.3
  • 11
    • 33748914094 scopus 로고    scopus 로고
    • Digital repeat analysis; Setup and operation
    • J Nol G Isouard J Mirecki 2006 Digital repeat analysis; setup and operation J Digit Imaging 19 2 159 166
    • (2006) J Digit Imaging , vol.19 , Issue.2 , pp. 159-166
    • Nol, J.1    Isouard, G.2    Mirecki, J.3
  • 12
    • 34547755176 scopus 로고    scopus 로고
    • Managing patient dose in digital radiology. A report of the International Commission on Radiological Protection
    • International Commission on Radiological Protection (ICRP publication 93)
    • International Commission on Radiological Protection (ICRP publication 93) 2004 Managing patient dose in digital radiology. A report of the International Commission on Radiological Protection Ann ICRP 34 1 1 73
    • (2004) Ann ICRP , vol.34 , Issue.1 , pp. 1-73
  • 13
    • 33645213635 scopus 로고    scopus 로고
    • Dosimetry and image quality in digital radiology from online audit of the X-ray system
    • E Vano JM Fernandez JI Ten 2005 Dosimetry and image quality in digital radiology from online audit of the X-ray system Radiat Prot Dosim 117 1-3 199 203
    • (2005) Radiat Prot Dosim , vol.117 , Issue.13 , pp. 199-203
    • Vano, E.1    Fernandez, J.M.2    Ten, J.I.3
  • 14
    • 33645241958 scopus 로고    scopus 로고
    • The DIMOND project and its impact on radiation protection
    • K Faulkner 2005 The DIMOND project and its impact on radiation protection Radiat Prot Dosim 117 1-3 3 6
    • (2005) Radiat Prot Dosim , vol.117 , Issue.13 , pp. 3-6
    • Faulkner, K.1
  • 15
    • 84864155161 scopus 로고    scopus 로고
    • SENTINEL: Safety and efficacy for new techniques and imaging using new equipment to support european legislation
    • Accessed 7 April 2007
    • SENTINEL: Safety and Efficacy for New Techniques and Imaging using New Equipment to Support European Legislation. European Coordination Action, (2005-2007). http://www.sentinel.eu.com/Documents/Project+Presentation.pdf. Accessed 7 April 2007
    • (2005) European Coordination Action
  • 16
    • 0032613086 scopus 로고    scopus 로고
    • Comparative reject analysis in conventional film-screen and digital storage phosphor radiography
    • S Peer R Peer 1999 Comparative reject analysis in conventional film-screen and digital storage phosphor radiography Eur Radiol 9 8 1693 1696
    • (1999) Eur Radiol , vol.9 , Issue.8 , pp. 1693-1696
    • Peer, S.1    Peer, R.2
  • 17
    • 0035030852 scopus 로고    scopus 로고
    • Comparative reject analysis in conventional film-screen and digital storage phosphor radiography
    • S Peer R Peer 2001 Comparative reject analysis in conventional film-screen and digital storage phosphor radiography Radiat Prot Dosim 94 1-2 69 71
    • (2001) Radiat Prot Dosim , vol.94 , Issue.12 , pp. 69-71
    • Peer, S.1    Peer, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.