메뉴 건너뛰기




Volumn 30, Issue 2, 2009, Pages 321-326

Usefulness of the application of the BLADE technique to reduce motion artifacts on navigation-triggered prospective acquisition correction (PACE) T2-weighted MRI (T2WI) of the liver

Author keywords

BLADE; Hepatic imaging; Motion artifacts; PACE; T2 weighted imaging

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFACT REDUCTION; BILOMA; CLINICAL TRIAL; CONTRAST ENHANCEMENT; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; DIFFUSION WEIGHTED IMAGING; FEMALE; HUMAN; IMAGE ANALYSIS; IMAGE QUALITY; IMAGE RECONSTRUCTION; JACKKNIFE TEST; LIVER; LIVER ABSCESS; LIVER CELL CARCINOMA; LIVER CYST; LIVER HEMANGIOMA; LIVER METASTASIS; LIVER NODULE; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; RECEIVER OPERATING CHARACTERISTIC;

EID: 68049128299     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.21855     Document Type: Article
Times cited : (23)

References (18)
  • 2
    • 34547897640 scopus 로고    scopus 로고
    • Image quality and focal lesion detection on T2-weighted MR imaging of the liver: Comparison of two high-resolution free-breathing imaging techniques with two breath-hold imaging techniques
    • Lee SS, Byun JH, Hong HS, et al. Image quality and focal lesion detection on T2-weighted MR imaging of the liver: comparison of two high-resolution free-breathing imaging techniques with two breath-hold imaging techniques. J Magn Reson Imaging 2007;26:323-330.
    • (2007) J Magn Reson Imaging , vol.26 , pp. 323-330
    • Lee, S.S.1    Byun, J.H.2    Hong, H.S.3
  • 3
    • 38449097388 scopus 로고    scopus 로고
    • Comparison of three free-breathing T2-weighted MRI sequences in the evaluation of focal liver lesions
    • Kim BS, Kim JH, Choi GM, et al. Comparison of three free-breathing T2-weighted MRI sequences in the evaluation of focal liver lesions. AJR Am J Roentgenol 2008;190:W19-W27.
    • (2008) AJR Am J Roentgenol , vol.190
    • Kim, B.S.1    Kim, J.H.2    Choi, G.M.3
  • 4
    • 0032754594 scopus 로고    scopus 로고
    • Motion correction with PROPELLER MRI: Application to head motion and free-breathing cardiac imaging
    • Pipe JG. Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging. Magn Reson Med 1999;42:963-969.
    • (1999) Magn Reson Med , vol.42 , pp. 963-969
    • Pipe, J.G.1
  • 6
    • 43649095472 scopus 로고    scopus 로고
    • Depiction of the cranial nerves within the brain stem with use of PROPELLER multishot diffusion-weighted imaging
    • DOI 10.3174/ajnr.A0957
    • Adachi M, Kabasawa H, Kawaguchi E. Depiction of the cranial nerves within the brain stem with use of PROPELLER multishot diffusion-weighted imaging. AJNR Am J Neuroradiol 2008;29:911-912. (Pubitemid 351684965)
    • (2008) American Journal of Neuroradiology , vol.29 , Issue.5 , pp. 911-912
    • Adachi, M.1    Kabasawa, H.2    Kawaguchi, E.3
  • 7
    • 0038517259 scopus 로고    scopus 로고
    • Brain imaging in the unsedated pediatric patient: Comparison of periodically rotated overlapping parallel lines with enhanced reconstruction and single-shot fast spin-echo sequences
    • Forbes KP, Pipe JG, Karis JP, Farthing V, Heiserman JE. Brain imaging in the unsedated pediatric patient: comparison of periodically rotated overlapping parallel lines with enhanced reconstruction and single-shot fast spin-echo sequences. AJNR Am J Neuroradiol 2003;24:794-798. (Pubitemid 36617403)
    • (2003) American Journal of Neuroradiology , vol.24 , Issue.5 , pp. 794-798
    • Forbes, K.P.1    Pipe, J.G.2    Karis, J.P.3    Farthing, V.4    Heiserman, J.E.5
  • 8
    • 46649083409 scopus 로고    scopus 로고
    • Contrast-enhanced T1-weighted fluid-attenuated inversion-recovery BLADE magnetic resonance imaging of the brain: An alternative to spin-echo technique for detection of brain lesions in the unsedated pediatric patient?
    • Alibek S, Adamietz B, Cavallaro A, et al. Contrast-enhanced T1-weighted fluid-attenuated inversion-recovery BLADE magnetic resonance imaging of the brain: an alternative to spin-echo technique for detection of brain lesions in the unsedated pediatric patient? Acad Radiol 2008;15:986-995.
    • (2008) Acad Radiol , vol.15 , pp. 986-995
    • Alibek, S.1    Adamietz, B.2    Cavallaro, A.3
  • 9
    • 33748756419 scopus 로고    scopus 로고
    • Multishot diffusion-weighted PROPELLER magnetic resonance imaging of the abdomen
    • DOI 10.1097/01.rli.0000236808.84746.95, PII 0000442420061000000008
    • Deng J, Miller FH, Riad Salem, Omary RA, Larson AC. Multishot diffusion-weighted PROPELLER magnetic resonance imaging of abdomen. Invest Radiol 2006;41:769-775. (Pubitemid 44401304)
    • (2006) Investigative Radiology , vol.41 , Issue.10 , pp. 769-775
    • Deng, J.1    Miller, F.H.2    Salem, R.3    Omary, R.A.4    Larson, A.C.5
  • 11
    • 53249155042 scopus 로고    scopus 로고
    • MRI artifact reduction and quality improvement in the upper abdomen with PROPELLER and prospective acquisition correction (PACE) technique
    • Hirokawa Y, Isoda H, Maetani Y, Arizino S, Shimada K, Togashi K. MRI artifact reduction and quality improvement in the upper abdomen with PROPELLER and prospective acquisition correction (PACE) technique. AJR Am J Roentgenol 2008;191:1154-1158.
    • (2008) AJR Am J Roentgenol , vol.191 , pp. 1154-1158
    • Hirokawa, Y.1    Isoda, H.2    Maetani, Y.3    Arizino, S.4    Shimada, K.5    Togashi, K.6
  • 12
    • 53549091578 scopus 로고    scopus 로고
    • Evaluation of motion correction effect and image quality with the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) (BLADE) and parallel imaging acquisition technique in the upper abdomen
    • Hirokawa Y, Isoda H, Maetani Y, Arizono S, Shimada K, Togashi K. Evaluation of motion correction effect and image quality with the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) (BLADE) and parallel imaging acquisition technique in the upper abdomen. J Magn Reson Imaging 2008;28:957-962.
    • (2008) J Magn Reson Imaging , vol.28 , pp. 957-962
    • Hirokawa, Y.1    Isoda, H.2    Maetani, Y.3    Arizono, S.4    Shimada, K.5    Togashi, K.6
  • 13
    • 0025306872 scopus 로고
    • Liver-lesion tissue contrast on MR images: Effect of iron oxide concentration and magnetic field strength
    • Thickman D, Hendrick RE, Jerjian KA, Schanker CS. Liver-lesion tissue contrast on MR images: effect of iron oxide concentration and magnetic field strength. Radiology 1990;176:557-562. (Pubitemid 20225156)
    • (1990) Radiology , vol.176 , Issue.2 , pp. 557-562
    • Thickman, D.1    Hendrick, R.E.2    Jerjian, K.A.3    Schanker, C.S.4
  • 14
    • 4043148805 scopus 로고    scopus 로고
    • Observer studies involving detection and localization: Modeling analysis and validation
    • Chakraborty DP, Berbaum KS. Observer studies involving detection and localization: modeling analysis and validation. Med Phys 2004;31:2313-2330.
    • (2004) Med Phys , vol.31 , pp. 2313-2330
    • Chakraborty, D.P.1    Berbaum, K.S.2
  • 15
    • 33748427526 scopus 로고    scopus 로고
    • Analysis of location specific observer performance data: Validated extensions of jackknife free-response (JAFROC) method
    • Chakraborty DP. Analysis of location specific observer performance data: validated extensions of jackknife free-response (JAFROC) method. Acad Radiol 2006;13:1187-1193.
    • (2006) Acad Radiol , vol.13 , pp. 1187-1193
    • Chakraborty, D.P.1
  • 16
    • 0031001798 scopus 로고    scopus 로고
    • Liver T2-weighted MR imaging: Comparison of fast and conventional half- Fourier single-shot turbo spin-echo, breath-hold turbo spin-echo, and respiratory-triggered turbo spin-echo sequences
    • Tang Y, Yamashita Y, Namimoto T, Abe Y, Takahashi M. Liver T2-weighted MR imaging: comparison of fast and conventional half-Fourier single-shot turbo spin-echo, breath-hold turbo spinecho, and respiratory-triggered turbo spin-echo sequences. Radiology 1997;203:766-772. (Pubitemid 27227428)
    • (1997) Radiology , vol.203 , Issue.3 , pp. 766-772
    • Tang, Y.1    Yamashita, Y.2    Namimoto, T.3    Abe, Y.4    Takahashi, M.5
  • 17
    • 0029930953 scopus 로고    scopus 로고
    • Detection of focal hepatic lesions with MR imaging: Prospective comparison of T2-weighted fast spin-echo with and without fat suppression, T2-weighted breath-hold fast spin-echo, and gadolinium chelate-enhanced 3D gradient- Recalled imaging
    • Soyer P, de Givry SC, Gueye C, Lenormand S, Somveille E, Scherrer A. Detection of focal hepatic lesions with MR imaging: prospective comparison of T2-weighted fast spin-echo with and without fat suppression, T2-weighted breath-hold fast spin-echo, and gadolinium chelate-enhanced 3D gradient-recalled imaging. AJR Am J Roentgenol 1996;166:1115-1121. (Pubitemid 26122957)
    • (1996) American Journal of Roentgenology , vol.166 , Issue.5 , pp. 1115-1121
    • Soyer, P.1    De Givry, S.C.2    Gueye, C.3    Lenormand, S.4    Somveille, E.5    Scherrer, A.6
  • 18
    • 27944503488 scopus 로고    scopus 로고
    • Magnetic resonance cholangiopancreatography using a free-breathing T2-weighted turbo spin-echo sequence with navigator-triggered prospective acquisition correction
    • DOI 10.1016/j.mri.2005.07.002, PII S0730725X05002328
    • Asbach P, Klessen C, Kroencke TJ, et al. Magnetic resonance cholangiopancreatography using a free-breathing T2-weighted turbo spin-echo sequence with navigator-triggered prospective acquisition correction. Magn Reson Imaging 2005;23:939-945. (Pubitemid 41681674)
    • (2005) Magnetic Resonance Imaging , vol.23 , Issue.9 , pp. 939-945
    • Asbach, P.1    Klessen, C.2    Kroencke, T.J.3    Kluner, C.4    Stemmer, A.5    Hamm, B.6    Taupitz, M.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.