메뉴 건너뛰기




Volumn 9, Issue 2, 2009, Pages 159-162

Role of heme oxygenase-1/carbon monoxide system in pulmonary ischemia-reperfusion injury

Author keywords

Carbon monoxide; Heme oxygenase 1; Ischemia reperfusion injury; Lung

Indexed keywords

CARBON MONOXIDE; CARBOXYHEMOGLOBIN; HEME OXYGENASE 1; HEMIN; PROTOPORPHYRIN ZINC;

EID: 68049101261     PISSN: 15699293     EISSN: None     Source Type: Journal    
DOI: 10.1510/icvts.2008.196089     Document Type: Article
Times cited : (6)

References (11)
  • 4
    • 0027521594 scopus 로고
    • Prevention of lung reperfusion injury in rabbits by a monoclonal antibody against interleukin-8
    • DOI 10.1038/365654a0
    • Sekido N, Mukaida N, Harada A, Nakanishi I, Watanabe Y, Matsushima K. Prevention of lung reperfusion injury in rabbits by a monoclonal antibody against interleukin-8wJx. Nature 1993;365:654-657. (Pubitemid 23350537)
    • (1993) Nature , vol.365 , Issue.6447 , pp. 654-657
    • Sekido, N.1    Mukaida, N.2    Harada, A.3    Nakanishi, I.4    Watanabe, Y.5    Matsushima, K.6
  • 5
    • 0034705371 scopus 로고    scopus 로고
    • Prevention of hypoxia-induced pulmonary hypertension by enhancement of endogenous heme oxygenase-1 in the rat
    • Christou H, Morita T, Hsieh CM, Koike H, Arkonac B, Perrella MA, Kourembanas S. Prevention of hypoxia-induced pulmonary hypertension by enhancement of endogenous heme oxygenase-1 in the rat[J]. Circ Res 2000;86:1224-1229. (Pubitemid 30436662)
    • (2000) Circulation Research , vol.86 , Issue.12 , pp. 1224-1229
    • Christou, H.1    Morita, T.2    Hsieh, C.-M.3    Koike, H.4    Arkonac, B.5    Perrella, M.A.6    Kourembanas, S.7
  • 6
    • 29744444874 scopus 로고    scopus 로고
    • Protective effect of hemoglobin-induced heme oxygenase-1 on injured lungs caused by limb ischemia-reperfusion in rats
    • Zhou JL, Zhu XG, Zhang GS, Ling T. Protective effect of hemoglobininduced heme oxygenase-1 on injured lungs caused by limb ischemiareperfusion in rats[J]. Chin J Traumatol 2002;5:86-91. (Pubitemid 43026802)
    • (2002) Chinese Journal of Traumatology - English Edition , vol.5 , Issue.2 , pp. 86-91
    • Zhou, J.1    Zhu, X.2    Zhang, G.3    Ling, T.4
  • 7
    • 68049086339 scopus 로고    scopus 로고
    • Double wavelength ration measure of carbon monoxide hemoglobin
    • J
    • Le HP, Song XX, Liu HP. Double wavelength ration measure of carbon monoxide hemoglobin [J]. Chin J Clinical Checkout 1996;14:87-88.
    • (1996) Chin J Clinical Checkout , vol.14 , pp. 87-88
    • Le, H.P.1    Song, X.X.2    Liu, H.P.3
  • 8
    • 29744444874 scopus 로고    scopus 로고
    • Protective effect of hemoglobin-induced heme oxygenase-1 on injured lungs caused by limb ischemia-reperfusion in rats
    • Zhou JL, Zhu XG, Zhang GS, Ling T. Protective effect of hemoglobininduced heme oxygenase-1 on injured lungs caused by limb ischemiareperfusion in rats[J]. Chin J Traumatol 2002;5:86-91. (Pubitemid 43026802)
    • (2002) Chinese Journal of Traumatology - English Edition , vol.5 , Issue.2 , pp. 86-91
    • Zhou, J.1    Zhu, X.2    Zhang, G.3    Ling, T.4
  • 9
    • 0026698131 scopus 로고
    • Reperfusion after a two-hour period of pulmonary artery occlusion causes pulmonary necrosis
    • J
    • Murata T, Nakazawa H, Mori I, Ohta Y, Yamabayashi H. Reperfusion after a two-hour period of pulmonary artery occlusion causes pulmonary necrosis[J]. Am Rev Respir Dis 1992;146:1048-1053.
    • (1992) Am Rev Respir Dis , vol.146 , pp. 1048-1053
    • Murata, T.1    Nakazawa, H.2    Mori, I.3    Ohta, Y.4    Yamabayashi, H.5
  • 10
    • 0028097746 scopus 로고
    • Sources of carbon monoxide (CO) in biological systems and applications of CO detection technologies
    • Rodeger PA, Vreman HJ, Dennery PA, Stevenson DK. Sources of carbon monoxide (CO) in biological systems and applications of CO detection technologies. Semi Perinato 1994;18:2-10.
    • (1994) Semi Perinato , vol.18 , pp. 2-10
    • Rodeger, P.A.1    Vreman, H.J.2    Dennery, P.A.3    Stevenson, D.K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.