메뉴 건너뛰기




Volumn 15, Issue 1, 2008, Pages 33-53

The influence of fitting algorithm and scanning speed on roundness error for 50 mm standard ring measurement using CMM

Author keywords

CMM accuracy; Fitting methods; Precision engineering; Probe scan speed; Roundness errors

Indexed keywords

APPLICATION RANGE; BEST FIT; CMM ACCURACY; DATA ANALYSIS SOFTWARES; ERROR CHARACTERISTICS; ERROR FORMULAE; FITTING ALGORITHMS; FITTING METHOD; REFERENCE DATA; ROUNDNESS ERROR; ROUNDNESS MEASUREMENT; SCANNING SPEED; SOFTWARE METHODS; TOUCH PROBE; TROUBLESHOOTING; WORK PIECES;

EID: 68049093664     PISSN: 08608229     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (23)

References (14)
  • 1
    • 77956200481 scopus 로고    scopus 로고
    • Automatic Execution of Inspection Plans with the I++DME Interface for Industrial Coordinate Measurements
    • Topfer S. C. N., Linss G., Rosenberger M., Nehse U., Weissensee K.: "Automatic Execution of Inspection Plans with the I++DME Interface for Industrial Coordinate Measurements", Metrology MS, vol. 14, no. 1, pp.71-88, 2007.
    • (2007) Metrology MS , vol.14 , Issue.1 , pp. 71-88
    • Topfer, S.C.N.1    Linss, G.2    Rosenberger, M.3    Nehse, U.4    Weissensee, K.5
  • 5
    • 77956197247 scopus 로고    scopus 로고
    • The Errors Occurring in the CMM Fitting Method
    • Swornowski P., Rucki M.: The Errors Occurring in the CMM Fitting Method";, Measurement Science Review, vol. 3, Sec. 3, pp.135-138, 2003.
    • (2003) Measurement Science Review , vol.3 , pp. 135-138
    • Swornowski, P.1    Rucki, M.2
  • 6
    • 34248137058 scopus 로고    scopus 로고
    • Methods and Artifacts for Comparison of Scanning CMM Performance
    • USA
    • Farooqui Sami A., Morse Edward P.: Methods and Artifacts for Comparison of Scanning CMM Performance";, ASME, USA, vol. 7, no. 1, pp.72-80, 2007.
    • (2007) ASME , vol.7 , Issue.1 , pp. 72-80
    • Farooqui, S.A.1    Morse Edward, P.2
  • 7
    • 3242701034 scopus 로고
    • Performance Measures for Geometric Fitting in the NIST Algorithm Testing and Evaluation Program for Coordinate Measurement Systems
    • USA
    • Hopp H., Levenson M.: Performance Measures for Geometric Fitting in the NIST Algorithm Testing and Evaluation Program for Coordinate Measurement Systems";, NIST Jr. of Research, USA, vol. 100, no. 5, pp.563-574, 1995.
    • (1995) NIST Jr. of Research , vol.100 , Issue.5 , pp. 563-574
    • Hopp, H.1    Levenson, M.2
  • 9
    • 17244366572 scopus 로고    scopus 로고
    • Modeling of Spatial Constraint in CMM Error for Uncertainty Estimation
    • Eindhoven, Netherlands May
    • rd Euspen International Conf., 26-30 May 2002, Eindhoven, Netherlands.
    • (2002) rd Euspen International Conf , pp. 26-30
    • Abbe, M.1    Takamasu, K.2
  • 10
    • 31644449682 scopus 로고    scopus 로고
    • Surface Fitting Taking into Account Uncertainty Structure in Coordinate Data
    • Forbes A.: Surface Fitting Taking into Account Uncertainty Structure in Coordinate Data", Meas. Sci. Technol., 2006, vol. 17, no. 3, pp.553-558.
    • (2006) Meas. Sci. Technol , vol.17 , Issue.3 , pp. 553-558
    • Forbes, A.1
  • 12
    • 77956193038 scopus 로고    scopus 로고
    • Uncertainty Evaluation of CMM by Modeling with Spatial Constraint
    • IIT Madras, India 21-24 November
    • th ISMQC), IIT Madras, India, 21-24 November 2007, pp.121-125.
    • (2007) th ISMQC) , pp. 121-125
    • Abbe, M.1    Takamasu, K.2
  • 13
    • 13844282288 scopus 로고    scopus 로고
    • International Standard: Geometrical Product SpecifiCations (GPS) - Acceptance and ReverifiCation Tests For Coordinate Measuring Machines (CMM) - Part 2: CMMs Used For Measuring Size
    • nd edition, 15-12
    • nd edition, 15-12-2001.
    • (2001)
  • 14
    • 77955418082 scopus 로고    scopus 로고
    • International Standard: Geometrical Product SpecifiCations (GPS) - Acceptance and ReverifiCation Tests For Coordinate Measuring Machines (CMM) - Part 4: CMMs Used In Scanning Measuring Mode
    • nd edition, 15-3
    • nd edition, 15-3-2000.
    • (2000)