메뉴 건너뛰기




Volumn 45, Issue 3, 2009, Pages 487-492

Voxel size and measures of individual resorption cavities in three-dimensional images of cancellous bone

Author keywords

Bone remodeling; Bone resorption; Cancellous bone; Histomorphometry; Imaging

Indexed keywords

ANIMAL TISSUE; ARTICLE; BIOMECHANICS; CANCELLOUS BONE; CONTROLLED STUDY; FEMALE; HISTOLOGY; IMAGE ANALYSIS; LUMBAR VERTEBRA; MORPHOLOGY; MORPHOMETRICS; NONHUMAN; OSTEOLYSIS; RAT; THREE DIMENSIONAL IMAGING;

EID: 67949106373     PISSN: 87563282     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.bone.2009.05.019     Document Type: Article
Times cited : (22)

References (24)
  • 1
    • 0034524907 scopus 로고    scopus 로고
    • Markers of bone turnover for the prediction of fracture risk
    • Garnero P. Markers of bone turnover for the prediction of fracture risk. Osteoporos. Int. 11 Suppl 6 (2000) S55-65
    • (2000) Osteoporos. Int. , vol.11 , Issue.SUPPL. 6
    • Garnero, P.1
  • 2
    • 0036065939 scopus 로고    scopus 로고
    • High bone turnover is intrinsically harmful: two paths to a similar conclusion. The Parfitt view
    • Parfitt A.M. High bone turnover is intrinsically harmful: two paths to a similar conclusion. The Parfitt view. J. Bone Miner. Res. 17 (2002) 1558-1559
    • (2002) J. Bone Miner. Res. , vol.17 , pp. 1558-1559
    • Parfitt, A.M.1
  • 3
    • 0141527583 scopus 로고    scopus 로고
    • Is the paradigm shifting?
    • Heaney R.P. Is the paradigm shifting?. Bone 33 (2003) 457-465
    • (2003) Bone , vol.33 , pp. 457-465
    • Heaney, R.P.1
  • 4
    • 43149112533 scopus 로고    scopus 로고
    • How can bone turnover modify bone strength independent of bone mass?
    • Hernandez C.J. How can bone turnover modify bone strength independent of bone mass?. Bone 42 (2008) 1014-1020
    • (2008) Bone , vol.42 , pp. 1014-1020
    • Hernandez, C.J.1
  • 5
    • 0033963131 scopus 로고    scopus 로고
    • Is BMU-coupling a strain-regulated phenomenon? A finite element analysis
    • Smit T.H., and Burger E.H. Is BMU-coupling a strain-regulated phenomenon? A finite element analysis. J. Bone Miner. Res. 15 (2000) 301-307
    • (2000) J. Bone Miner. Res. , vol.15 , pp. 301-307
    • Smit, T.H.1    Burger, E.H.2
  • 7
    • 33746421027 scopus 로고    scopus 로고
    • A biomechanical analysis of the effects of resorption cavities on cancellous bone strength
    • Hernandez C.J., Gupta A., and Keaveny T.M. A biomechanical analysis of the effects of resorption cavities on cancellous bone strength. J. Bone Miner. Res. 21 (2006) 1248-1255
    • (2006) J. Bone Miner. Res. , vol.21 , pp. 1248-1255
    • Hernandez, C.J.1    Gupta, A.2    Keaveny, T.M.3
  • 9
    • 0023488581 scopus 로고
    • Bone histomorphometry: standardization of nomenclature, symbols, and units. Report of the ASBMR Histomorphometry Nomenclature Committee
    • Parfitt A.M., Drezner M.K., Glorieux F.H., Kanis J.A., Malluche H., Meunier P.J., et al. Bone histomorphometry: standardization of nomenclature, symbols, and units. Report of the ASBMR Histomorphometry Nomenclature Committee. J. Bone Miner. Res. 2 (1987) 595-610
    • (1987) J. Bone Miner. Res. , vol.2 , pp. 595-610
    • Parfitt, A.M.1    Drezner, M.K.2    Glorieux, F.H.3    Kanis, J.A.4    Malluche, H.5    Meunier, P.J.6
  • 10
    • 0014370242 scopus 로고
    • Scanning electron microscopy of bone
    • :4-4B
    • Boyde A., and Hobdell M. Scanning electron microscopy of bone. Calcif. Tissue Res. 2 Suppl (1968) :4-4B
    • (1968) Calcif. Tissue Res. , vol.2 , Issue.SUPPL
    • Boyde, A.1    Hobdell, M.2
  • 11
    • 0025370290 scopus 로고
    • Consequences of the remodelling process for vertebral trabecular bone structure: a scanning electron microscopy study (uncoupling of unloaded structures)
    • Mosekilde L. Consequences of the remodelling process for vertebral trabecular bone structure: a scanning electron microscopy study (uncoupling of unloaded structures). Bone Miner. 10 (1990) 13-35
    • (1990) Bone Miner. , vol.10 , pp. 13-35
    • Mosekilde, L.1
  • 12
    • 0027313985 scopus 로고
    • Histomorphometry of Howship's lacunae formed in vivo and in vitro: depths and volumes measured by scanning electron and confocal microscopy
    • Jones S.J., and Boyde A. Histomorphometry of Howship's lacunae formed in vivo and in vitro: depths and volumes measured by scanning electron and confocal microscopy. Bone 14 (1993) 455-460
    • (1993) Bone , vol.14 , pp. 455-460
    • Jones, S.J.1    Boyde, A.2
  • 13
    • 0142213557 scopus 로고    scopus 로고
    • Bone structure and mineralization demonstrated using synchrotron radiation computed tomography (SR-CT) in animal models: preliminary findings
    • Ito M., Ejiri S., Jinnai H., Kono J., Ikeda S., Nishida A., et al. Bone structure and mineralization demonstrated using synchrotron radiation computed tomography (SR-CT) in animal models: preliminary findings. J. Bone Miner. Metab. 21 (2003) 287-293
    • (2003) J. Bone Miner. Metab. , vol.21 , pp. 287-293
    • Ito, M.1    Ejiri, S.2    Jinnai, H.3    Kono, J.4    Ikeda, S.5    Nishida, A.6
  • 14
    • 35449003698 scopus 로고    scopus 로고
    • A computational assessment of the independent contribution of changes in canine trabecular bone volume fraction and microarchitecture to increased bone strength with suppression of bone turnover
    • Eswaran S.K., Allen M.R., Burr D.B., and Keaveny T.M. A computational assessment of the independent contribution of changes in canine trabecular bone volume fraction and microarchitecture to increased bone strength with suppression of bone turnover. J. Biomech. 40 (2007) 3424-3431
    • (2007) J. Biomech. , vol.40 , pp. 3424-3431
    • Eswaran, S.K.1    Allen, M.R.2    Burr, D.B.3    Keaveny, T.M.4
  • 15
    • 33847711500 scopus 로고    scopus 로고
    • Automated high-resolution three-dimensional fluorescence imaging of large biological specimens
    • Kazakia G.J., Lee J.J., Singh M., Bigley R.F., Martin R.B., and Keaveny T.M. Automated high-resolution three-dimensional fluorescence imaging of large biological specimens. J. Microsc. 225 (2007) 109-117
    • (2007) J. Microsc. , vol.225 , pp. 109-117
    • Kazakia, G.J.1    Lee, J.J.2    Singh, M.3    Bigley, R.F.4    Martin, R.B.5    Keaveny, T.M.6
  • 16
    • 0030898662 scopus 로고    scopus 로고
    • Three-dimensional methods for quantification of cancellous bone architecture
    • Odgaard A. Three-dimensional methods for quantification of cancellous bone architecture. Bone 20 (1997) 315-328
    • (1997) Bone , vol.20 , pp. 315-328
    • Odgaard, A.1
  • 20
    • 0028309520 scopus 로고
    • Stereological considerations concerning the measurement of individual osteoid seams and resorption cavities
    • Hauge E.M., Mosekilde L., and Melsen F. Stereological considerations concerning the measurement of individual osteoid seams and resorption cavities. Bone Miner. 26 (1994) 89-90
    • (1994) Bone Miner. , vol.26 , pp. 89-90
    • Hauge, E.M.1    Mosekilde, L.2    Melsen, F.3
  • 21
    • 0025024727 scopus 로고
    • A computerised technique for the quantitative assessment of resorption cavities in trabecular bone
    • Garrahan N.J., Croucher P.I., and Compston J.E. A computerised technique for the quantitative assessment of resorption cavities in trabecular bone. Bone 11 (1990) 241-245
    • (1990) Bone , vol.11 , pp. 241-245
    • Garrahan, N.J.1    Croucher, P.I.2    Compston, J.E.3
  • 23
    • 33845961684 scopus 로고    scopus 로고
    • A biomechanical perspective on bone quality
    • Hernandez C.J., and Keaveny T.M. A biomechanical perspective on bone quality. Bone 39 (2006) 1173-1181
    • (2006) Bone , vol.39 , pp. 1173-1181
    • Hernandez, C.J.1    Keaveny, T.M.2
  • 24
    • 37349123533 scopus 로고    scopus 로고
    • Validity of serial milling-based imaging system for microdamage quantification
    • Bigley R.F., Singh M., Hernandez C.J., Kazakia G.J., Martin R.B., and Keaveny T.M. Validity of serial milling-based imaging system for microdamage quantification. Bone 42 (2008) 212-215
    • (2008) Bone , vol.42 , pp. 212-215
    • Bigley, R.F.1    Singh, M.2    Hernandez, C.J.3    Kazakia, G.J.4    Martin, R.B.5    Keaveny, T.M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.