메뉴 건너뛰기




Volumn 136, Issue 2, 2009, Pages 224-229

Effect of screw diameter on orthodontic skeletal anchorage

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BONE SCREW; CADAVER; COMPARATIVE STUDY; DENTAL CARE; ELECTRONICS; HUMAN; INSTRUMENTATION; JAW; METHODOLOGY; ORTHODONTICS; TOOTH IMPLANTATION;

EID: 67949091337     PISSN: 08895406     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ajodo.2007.07.031     Document Type: Article
Times cited : (41)

References (18)
  • 3
    • 4444308807 scopus 로고    scopus 로고
    • Severe anterior open-bite case treated using titanium screw anchorage
    • Kuroda S., Katayama A., and Takano-Yamamoto T. Severe anterior open-bite case treated using titanium screw anchorage. Angle Orthod 74 (2004) 558-567
    • (2004) Angle Orthod , vol.74 , pp. 558-567
    • Kuroda, S.1    Katayama, A.2    Takano-Yamamoto, T.3
  • 4
    • 0035344075 scopus 로고    scopus 로고
    • A clinical and histological evaluation of titanium mini-implants as anchors for orthodontic intrusion in the beagle dog
    • Ohmae M., Saito S., Morohashi T., Seki K., Qu H., Kanomi R., et al. A clinical and histological evaluation of titanium mini-implants as anchors for orthodontic intrusion in the beagle dog. Am J Orthod Dentofacial Orthop 119 (2001) 489-497
    • (2001) Am J Orthod Dentofacial Orthop , vol.119 , pp. 489-497
    • Ohmae, M.1    Saito, S.2    Morohashi, T.3    Seki, K.4    Qu, H.5    Kanomi, R.6
  • 5
    • 0035407943 scopus 로고    scopus 로고
    • Micro-implant anchorage for treatment of skeletal Class I bialveolar protrusion
    • Park H.S., Bae S.M., Kyung H.M., and Sung J.H. Micro-implant anchorage for treatment of skeletal Class I bialveolar protrusion. J Clin Orthod 35 (2001) 417-422
    • (2001) J Clin Orthod , vol.35 , pp. 417-422
    • Park, H.S.1    Bae, S.M.2    Kyung, H.M.3    Sung, J.H.4
  • 6
    • 0036777545 scopus 로고    scopus 로고
    • A simple method of molar uprighting with micro-implant anchorage
    • Park H.S., Kyung H.M., and Sung J.H. A simple method of molar uprighting with micro-implant anchorage. J Clin Orthod 36 (2002) 592-596
    • (2002) J Clin Orthod , vol.36 , pp. 592-596
    • Park, H.S.1    Kyung, H.M.2    Sung, J.H.3
  • 7
    • 1342308955 scopus 로고    scopus 로고
    • A new bone screw for orthodontic anchorage
    • Lin J.C., and Liou E.J. A new bone screw for orthodontic anchorage. J Clin Orthod 37 (2003) 676-681
    • (2003) J Clin Orthod , vol.37 , pp. 676-681
    • Lin, J.C.1    Liou, E.J.2
  • 8
    • 32944471409 scopus 로고    scopus 로고
    • Mini-implants: where are we?
    • Melsen B. Mini-implants: where are we?. J Clin Orthod 39 (2005) 539-547
    • (2005) J Clin Orthod , vol.39 , pp. 539-547
    • Melsen, B.1
  • 9
    • 3042598772 scopus 로고    scopus 로고
    • Do miniscrews remain stationary under orthodontic forces?
    • Liou E.J., Pai B.C., and Lin J.C. Do miniscrews remain stationary under orthodontic forces?. Am J Orthod Dentofacial Orthop 126 (2004) 42-47
    • (2004) Am J Orthod Dentofacial Orthop , vol.126 , pp. 42-47
    • Liou, E.J.1    Pai, B.C.2    Lin, J.C.3
  • 11
    • 1042284432 scopus 로고    scopus 로고
    • Immediate loading of implants used for orthodontic anchorage
    • Melsen B., and Costa A. Immediate loading of implants used for orthodontic anchorage. Clin Orthod Res 3 (2000) 23-28
    • (2000) Clin Orthod Res , vol.3 , pp. 23-28
    • Melsen, B.1    Costa, A.2
  • 12
    • 54849439166 scopus 로고    scopus 로고
    • The analysis of failure cases using Orthoanchor K1 mini-implant system as orthodontic anchorage
    • (Spec Iss B):B-214, 1624
    • Cheng H.C., Yen E., Chen L.S., and Lee S.T. The analysis of failure cases using Orthoanchor K1 mini-implant system as orthodontic anchorage. J Dent Res 82 (2003) (Spec Iss B):B-214, 1624
    • (2003) J Dent Res , vol.82
    • Cheng, H.C.1    Yen, E.2    Chen, L.S.3    Lee, S.T.4
  • 13
    • 1342322625 scopus 로고    scopus 로고
    • A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage
    • Cheng S.J., Tseng I.Y., Lee J.J., and Kok S.H. A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage. Int J Oral Maxillofac Implants 19 (2004) 100-106
    • (2004) Int J Oral Maxillofac Implants , vol.19 , pp. 100-106
    • Cheng, S.J.1    Tseng, I.Y.2    Lee, J.J.3    Kok, S.H.4
  • 14
    • 0019663098 scopus 로고
    • A 15-year study of osseointegrated implants in the treatment of the edentulous jaw
    • Adell R., Lekholm U., Rockler B., and Branemark P. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 6 (1981) 387-416
    • (1981) Int J Oral Surg , vol.6 , pp. 387-416
    • Adell, R.1    Lekholm, U.2    Rockler, B.3    Branemark, P.4
  • 15
    • 0024745830 scopus 로고
    • Osseointegration: current state of the art
    • Albrektsson T., and Lekholm U. Osseointegration: current state of the art. Dent Clin North Am 33 (1989) 537-554
    • (1989) Dent Clin North Am , vol.33 , pp. 537-554
    • Albrektsson, T.1    Lekholm, U.2
  • 18
    • 31144468795 scopus 로고    scopus 로고
    • Orthopedic orotraction with skeletal anchorage in a patient with maxillary hypoplasia and hypodontia
    • Kircelli B.H., Pekta Z.O., and Uckan S. Orthopedic orotraction with skeletal anchorage in a patient with maxillary hypoplasia and hypodontia. Angle Orthod 76 (2005) 156-163
    • (2005) Angle Orthod , vol.76 , pp. 156-163
    • Kircelli, B.H.1    Pekta, Z.O.2    Uckan, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.