메뉴 건너뛰기




Volumn 109, Issue 2, 2009, Pages 470-472

Autotriggering during pressure support ventilation due to cardiogenic oscillations

Author keywords

[No Author keywords available]

Indexed keywords

CISATRACURIUM; ETOMIDATE; FENTANYL; ISOFLURANE;

EID: 67849133462     PISSN: 00032999     EISSN: None     Source Type: Journal    
DOI: 10.1213/ane.0b013e3181a9d75a     Document Type: Article
Times cited : (9)

References (10)
  • 1
    • 0028037801 scopus 로고
    • Comparison of pressure and flow triggering systems during continuous positive airway pressure
    • Branson RD, Campbell RS, Davis K Jr, Johnson DJ II. Comparison of pressure and flow triggering systems during continuous positive airway pressure. Chest 1994;106:540-544
    • (1994) Chest , vol.106 , pp. 540-544
    • Branson, R.D.1    Campbell, R.S.2    Johnson II, D.J.3
  • 2
    • 29844448981 scopus 로고    scopus 로고
    • Bedside waveforms interpretation as a tool to identify patient-ventilator asynchronies
    • Georgopoulos D, Prinianakis G, Kondili E. Bedside waveforms interpretation as a tool to identify patient-ventilator asynchronies. Intensive Care Med 2006;32:34-47
    • (2006) Intensive Care Med , vol.32 , pp. 34-47
    • Georgopoulos, D.1    Prinianakis, G.2    Kondili, E.3
  • 3
    • 33644760530 scopus 로고    scopus 로고
    • Autotriggering of pressure support ventilation during general anesthesia
    • Coxon M, Sindhaker S, Hodzovic I. Autotriggering of pressure support ventilation during general anesthesia. Anaesthesia 2006;61:72-73
    • (2006) Anaesthesia , vol.61 , pp. 72-73
    • Coxon, M.1    Sindhaker, S.2    Hodzovic, I.3
  • 4
    • 0034088957 scopus 로고    scopus 로고
    • Autotriggering caused by cardiogenic oscillation during flow-triggered mechanical ventilation
    • Imanaka H, Nishimura M, Takeuchi M, Kimball W, Yahagi N, Kumon K. Autotriggering caused by cardiogenic oscillation during flow-triggered mechanical ventilation. Crit Care Med 2000;28:402-407
    • (2000) Crit Care Med , vol.28 , pp. 402-407
    • Imanaka, H.1    Nishimura, M.2    Takeuchi, M.3    Kimball, W.4    Yahagi, N.5    Kumon, K.6
  • 5
    • 0034049485 scopus 로고    scopus 로고
    • Flow triggering, pressure triggering and autotriggering during mechanical ventilation
    • Hill L, Pearl R. Flow triggering, pressure triggering and autotriggering during mechanical ventilation. Crit Care Med 2000;28:579-581
    • (2000) Crit Care Med , vol.28 , pp. 579-581
    • Hill, L.1    Pearl, R.2
  • 6
    • 70350690824 scopus 로고    scopus 로고
    • Operators manual, Apollo anesthesia machine. Drager Medical
    • Operators manual, Apollo anesthesia machine. Drager Medical
  • 7
    • 0036214120 scopus 로고    scopus 로고
    • Inappropriate ventilator triggering caused by an in-line suction catheter
    • Al-Khafaji A, Manning HL. Inappropriate ventilator triggering caused by an in-line suction catheter. Intensive Care Med 2002;2:515-519
    • (2002) Intensive Care Med , vol.2 , pp. 515-519
    • Al-Khafaji, A.1    Manning, H.L.2
  • 8
    • 34447340270 scopus 로고    scopus 로고
    • Asynchrony and cyclic variability in pressure support noninvasive ventilation
    • Achour L, Letellier C, Cuvelier A, Vérin E, Muir J. Asynchrony and cyclic variability in pressure support noninvasive ventilation. Comput Biol Med 2007;37:1308-1320
    • (2007) Comput Biol Med , vol.37 , pp. 1308-1320
    • Achour, L.1    Letellier, C.2    Cuvelier, A.3    Vérin, E.4    Muir, J.5
  • 10
    • 70350667211 scopus 로고    scopus 로고
    • Internal communication document
    • Internal communication document. Drager Medical, 2007
    • (2007) Drager Medical


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.