메뉴 건너뛰기




Volumn 394, Issue 3, 2009, Pages 475-481

Ex situ quantification of the cooling effect of liver vessels on radiofrequency ablation

Author keywords

Bipolar; Cooling effect; Heat sink effect; Liver; Radiofrequency ablation

Indexed keywords

ANIMAL TISSUE; ARTICLE; BLOOD FLOW; BLOOD VESSEL DIAMETER; CONTROLLED STUDY; COOLING; ELECTRODE; LIVER; LIVER BLOOD VESSEL; NONHUMAN; OCCLUSION; PRIORITY JOURNAL; RADIATION APPLICATOR; RADIOFREQUENCY ABLATION; SWINE;

EID: 67749139478     PISSN: 14352443     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00423-009-0480-1     Document Type: Article
Times cited : (33)

References (16)
  • 1
    • 38049138477 scopus 로고    scopus 로고
    • Radiofrequency ablation versus resection for resectable colorectal liver metastases: Time for a randomized trial?
    • 10.1245/s10434-007-9478-5
    • S Mulier Y Ni J Jamart L Michel G Marchal T Ruers 2008 Radiofrequency ablation versus resection for resectable colorectal liver metastases: time for a randomized trial? Ann Surg Oncol 15 144 157 10.1245/s10434-007-9478-5
    • (2008) Ann Surg Oncol , vol.15 , pp. 144-157
    • Mulier, S.1    Ni, Y.2    Jamart, J.3    Michel, L.4    Marchal, G.5    Ruers, T.6
  • 2
    • 22744441092 scopus 로고    scopus 로고
    • Local recurrence after hepatic radiofrequency coagulation: Multivariate meta-analysis and review of contributing factors
    • DOI 10.1097/01.sla.0000171032.99149.fe
    • S Mulier Y Ni J Jamart T Ruers G Marchal L Michel 2005 Local recurrence after hepatic radiofrequency coagulation: multivariate meta-analysis and review of contributing factors Ann Surg 242 158 171 10.1097/01.sla.0000171032.99149.fe (Pubitemid 41033431)
    • (2005) Annals of Surgery , vol.242 , Issue.2 , pp. 158-171
    • Mulier, S.1    Ni, Y.2    Jamart, J.3    Ruers, T.4    Marchal, G.5    Michel, L.6
  • 4
    • 0031879365 scopus 로고    scopus 로고
    • Radiofrequency ablation of porcine liver in vivo: Effects of blood flow and treatment time on lesion size
    • DOI 10.1097/00000658-199804000-00018
    • EJ Patterson CH Scudamore DA Owen AG Nagy AK Buczkowski 1998 Radiofrequency ablation of porcine liver in vivo: effects of blood flow and treatment time on lesion size Ann Surg 227 559 565 10.1097/00000658-199804000- 00018 (Pubitemid 28363274)
    • (1998) Annals of Surgery , vol.227 , Issue.4 , pp. 559-565
    • Patterson, E.J.1    Scudamore, C.H.2    Owen, D.A.3    Nagy, A.G.4    Buczkowski, A.K.5
  • 5
    • 40949138326 scopus 로고    scopus 로고
    • Influence of intrahepatic vessels on volume and shape of percutaneous thermal ablation zones: In vivo evaluation in a porcine model
    • BB Frericks JP Ritz T Albrecht S Valdeig A Schenk KJ Wolf K Lehmann 2008 Influence of intrahepatic vessels on volume and shape of percutaneous thermal ablation zones: in vivo evaluation in a porcine model Invest Radiol 43 211 218
    • (2008) Invest Radiol , vol.43 , pp. 211-218
    • Frericks, B.B.1    Ritz, J.P.2    Albrecht, T.3    Valdeig, S.4    Schenk, A.5    Wolf, K.J.6    Lehmann, K.7
  • 9
    • 34248570990 scopus 로고    scopus 로고
    • Improving laser-induced thermotherapy of liver metastases - Effects of arterial microembolization and complete blood flow occlusion
    • DOI 10.1016/j.ejso.2007.02.028, PII S0748798307000959
    • JP Ritz KS Lehmann U Zurbuchen F Wacker F Brehm C Isbert CT Germer HJ Buhr C Holmer 2007 Improving laser-induced thermotherapy of liver metastases-effects of arterial microembolization and complete blood flow occlusion Eur J Surg Oncol 33 608 615 10.1016/j.ejso.2007.02.028 (Pubitemid 46758869)
    • (2007) European Journal of Surgical Oncology , vol.33 , Issue.5 , pp. 608-615
    • Ritz, J.-P.1    Lehmann, K.S.2    Zurbuchen, U.3    Wacker, F.4    Brehm, F.5    Isbert, C.6    Germer, C.T.7    Buhr, H.J.8    Holmer, C.9
  • 10
    • 33745603519 scopus 로고    scopus 로고
    • In-Vivo Evaluation of a Novel Bipolar Radiofrequency Device for Interstitial Thermotherapy of Liver Tumors During Normal and Interrupted Hepatic Perfusion
    • DOI 10.1016/j.jss.2005.09.028, PII S0022480405005287
    • JP Ritz KS Lehmann C Isbert C Reissfelder T Albrecht T Stein HJ Buhr 2006 In-vivo evaluation of a novel bipolar radiofrequency device for interstitial thermotherapy of liver tumors during normal and interrupted hepatic perfusion J Surg Res 133 176 184 10.1016/j.jss.2005.09.028 (Pubitemid 44235771)
    • (2006) Journal of Surgical Research , vol.133 , Issue.2 , pp. 176-184
    • Ritz, J.-P.1    Lehmann, K.S.2    Isbert, C.3    Reissfelder, C.4    Albrecht, T.5    Stein, T.6    Buhr, H.J.7
  • 11
    • 33746398119 scopus 로고    scopus 로고
    • Effects of vascular perfusion on coagulation size in radiofrequency ablation of ex vivo perfused bovine livers
    • DOI 10.1097/01.rli.0000201231.60420.a2, PII 0000442420060400000009
    • RG Bitsch M Dux T Helmberger A Lubienski 2006 Effects of vascular perfusion on coagulation size in radiofrequency ablation of ex vivo perfused bovine livers Invest Radiol 41 422 427 10.1097/01.rli.0000201231.60420.a2 (Pubitemid 44284205)
    • (2006) Investigative Radiology , vol.41 , Issue.4 , pp. 422-427
    • Bitsch, R.G.1    Dux, M.2    Helmberger, T.3    Lubienski, A.4
  • 13
    • 29244459438 scopus 로고    scopus 로고
    • Bipolar radiofrequency ablation of liver metastases during laparotomy. First clinical experiences with a new multipolar ablation concept
    • DOI 10.1007/s00384-005-0781-y
    • JP Ritz KS Lehmann C Reissfelder T Albrecht B Frericks U Zurbuchen HJ Buhr 2006 Bipolar radiofrequency ablation of liver metastases during laparotomy. First clinical experiences with a new multipolar ablation concept Int J Colorectal Dis 21 25 32 10.1007/s00384-005-0781-y (Pubitemid 41829762)
    • (2006) International Journal of Colorectal Disease , vol.21 , Issue.1 , pp. 25-32
    • Ritz, J.-P.1    Lehmann, K.S.2    Reissfelder, C.3    Albrecht, T.4    Frericks, B.5    Zurbuchen, U.6    Buhr, H.J.7
  • 14
    • 27744566348 scopus 로고    scopus 로고
    • Multipolar radiofrequency ablation of hepatic tumors: Initial experience
    • DOI 10.1148/radiol.2373041104
    • BB Frericks JP Ritz A Roggan KJ Wolf T Albrecht 2005 Multipolar radiofrequency ablation of hepatic tumors: initial experience Radiology 237 1056 1062 10.1148/radiol.2373041104 (Pubitemid 41636401)
    • (2005) Radiology , vol.237 , Issue.3 , pp. 1056-1062
    • Frericks, B.B.1    Ritz, J.P.2    Roggan, A.3    Wolf, K.-J.4    Albrecht, T.5
  • 15
    • 47249161045 scopus 로고    scopus 로고
    • Large (> or =5.0-cm) HCCs: Multipolar RF ablation with three internally cooled bipolar electrodes-initial experience in 26 patients
    • 10.1148/radiol.2481071101
    • O Seror G N'Kontchou M Ibraheem Y Ajavon C Barrucand N Ganne E Coderc JC Trinchet M Beaugrand N Sellier 2008 Large (> or =5.0-cm) HCCs: multipolar RF ablation with three internally cooled bipolar electrodes-initial experience in 26 patients Radiology 248 288 296 10.1148/radiol.2481071101
    • (2008) Radiology , vol.248 , pp. 288-296
    • Seror, O.1    N'Kontchou, G.2    Ibraheem, M.3    Ajavon, Y.4    Barrucand, C.5    Ganne, N.6    Coderc, E.7    Trinchet, J.C.8    Beaugrand, M.9    Sellier, N.10
  • 16
    • 34247392012 scopus 로고    scopus 로고
    • Investigation of the influence of blood flow rate on large vessel cooling in hepatic radiofrequency ablation
    • DOI 10.1515/BMT.2006.067
    • C Welp S Siebers H Ermert J Werner 2006 Investigation of the influence of blood flow rate on large vessel cooling in hepatic radiofrequency ablation Biomed Tech (Berl) 51 337 346 10.1515/BMT.2006.067 (Pubitemid 46630712)
    • (2006) Biomedizinische Technik , vol.51 , Issue.5-6 , pp. 337-346
    • Welp, C.1    Siebers, S.2    Ermert, H.3    Werner, J.4