메뉴 건너뛰기




Volumn 62, Issue 2, 2009, Pages 468-475

High resolution diffusion-weighted imaging using readout-segmented echo-planar imaging, parallel imaging and a two-dimensional navigator-based reacquisition

Author keywords

2D navigator; Diffusion weighted imaging; GRAPPA; Parallel imaging; Readout segmented EPI

Indexed keywords

DIFFUSION; MEDICAL IMAGING;

EID: 67749120068     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.22024     Document Type: Article
Times cited : (527)

References (33)
  • 1
    • 0028830962 scopus 로고
    • Acute human stroke studied by whole brain echo planar diffusion-weighted magnetic resonance imaging
    • Warach S, Gaa J, Siewert B, Wielopolski P, Edelman RR. Acute human stroke studied by whole brain echo planar diffusion-weighted magnetic resonance imaging. Ann Neurol 1995;37:231-241.
    • (1995) Ann Neurol , vol.37 , pp. 231-241
    • Warach, S.1    Gaa, J.2    Siewert, B.3    Wielopolski, P.4    Edelman, R.R.5
  • 9
    • 0028324684 scopus 로고
    • Correction of motional artefacts in diffusion-weighted MR images using navigator echoes
    • Ordidge RJ, Helpern JA, Qing ZX, Knight RA, Nagesh V. Correction of motional artefacts in diffusion-weighted MR images using navigator echoes. Magn Reson Imaging 1994;12:455-460.
    • (1994) Magn Reson Imaging , vol.12 , pp. 455-460
    • Ordidge, R.J.1    Helpern, J.A.2    Qing, Z.X.3    Knight, R.A.4    Nagesh, V.5
  • 10
    • 0028030441 scopus 로고
    • Analysis and correction of motion artifacts in diffusion weighted imaging
    • Anderson AW, Gore JC. Analysis and correction of motion artifacts in diffusion weighted imaging. Magn Reson Med 1994;32:379-387.
    • (1994) Magn Reson Med , vol.32 , pp. 379-387
    • Anderson, A.W.1    Gore, J.C.2
  • 11
    • 0042092052 scopus 로고    scopus 로고
    • Nonlinear phase correction for navigated diffusion imaging
    • Miller KL, Pauly JP. Nonlinear phase correction for navigated diffusion imaging. Magn Reson Med 2003;50:343-353.
    • (2003) Magn Reson Med , vol.50 , pp. 343-353
    • Miller, K.L.1    Pauly, J.P.2
  • 12
    • 0030705198 scopus 로고    scopus 로고
    • Isotropic diffusion-weighted and spiral-navigated interleaved EPI for routine imaging of acute stroke
    • Butts K, Pauly J, de Crespigny A, Moseley M. Isotropic diffusion-weighted and spiral-navigated interleaved EPI for routine imaging of acute stroke. Magn Reson Med 1997;38:741-749.
    • (1997) Magn Reson Med , vol.38 , pp. 741-749
    • Butts, K.1    Pauly, J.2    de Crespigny, A.3    Moseley, M.4
  • 13
    • 0033922197 scopus 로고    scopus 로고
    • Sampling and reconstruction effects due to motion in diffusion-weighted interleaved echo-planar imaging
    • Atkinson D, Porter DA, Hill DLG, Calamante F, Connelly A. Sampling and reconstruction effects due to motion in diffusion-weighted interleaved echo-planar imaging. Magn Reson Med 2000;44:101-109.
    • (2000) Magn Reson Med , vol.44 , pp. 101-109
    • Atkinson, D.1    Porter, D.A.2    Hill, D.L.G.3    Calamante, F.4    Connelly, A.5
  • 14
    • 10044240735 scopus 로고    scopus 로고
    • Self-navigated interleaved spiral (SNAILS): Application to high-resolution diffusion tensor imaging
    • Liu C, Bammer R, Kim D, Moseley ME. Self-navigated interleaved spiral (SNAILS): application to high-resolution diffusion tensor imaging. Magn Reson Med 2004;52:1388-1396.
    • (2004) Magn Reson Med , vol.52 , pp. 1388-1396
    • Liu, C.1    Bammer, R.2    Kim, D.3    Moseley, M.E.4
  • 16
    • 0036135369 scopus 로고    scopus 로고
    • Multishot diffusion-weighted FSE using PROPELLER MRI
    • Pipe JG, Farthing VG, Forbes KP. Multishot diffusion-weighted FSE using PROPELLER MRI. Magn Reson Med 2002;47:42-52.
    • (2002) Magn Reson Med , vol.47 , pp. 42-52
    • Pipe, J.G.1    Farthing, V.G.2    Forbes, K.P.3
  • 17
    • 0029880499 scopus 로고    scopus 로고
    • Single-shot diffusion MRI of human brain on a conventional clinical instrument
    • Liu G, van Gelderon P, Duyn J, Moonen CTW. Single-shot diffusion MRI of human brain on a conventional clinical instrument. Magn Reson Med 1996;35:671-677.
    • (1996) Magn Reson Med , vol.35 , pp. 671-677
    • Liu, G.1    van Gelderon, P.2    Duyn, J.3    Moonen, C.T.W.4
  • 18
    • 27644579499 scopus 로고    scopus 로고
    • PROPELLER EPI: An MRI technique suitable for diffusion tensor imaging at high field strength with reduced geometric distortions
    • Wang F-N, Huang T-Y, Lin F-H, Chuang T-C, Chen N-K, Chung H-W, Chen C-Y, Kwong KK. PROPELLER EPI: an MRI technique suitable for diffusion tensor imaging at high field strength with reduced geometric distortions. Magn Reson Med 2005;54:1232-1240.
    • (2005) Magn Reson Med , vol.54 , pp. 1232-1240
    • Wang, F.-N.1    Huang, T.-Y.2    Lin, F.-H.3    Chuang, T.-C.4    Chen, N.-K.5    Chung, H.-W.6    Chen, C.-Y.7    Kwong, K.K.8
  • 19
    • 0030786920 scopus 로고    scopus 로고
    • Diffusion-weighted multiple-shot echo planar imaging of humans without navigation
    • Robson MD, Anderson AW, Gore JC. Diffusion-weighted multiple-shot echo planar imaging of humans without navigation. Magn Reson Med 1997;38:82-88.
    • (1997) Magn Reson Med , vol.38 , pp. 82-88
    • Robson, M.D.1    Anderson, A.W.2    Gore, J.C.3
  • 20
    • 37549040796 scopus 로고    scopus 로고
    • Multi-shot diffusion-weighted EPI with readout mosaic segmentation and 2D navigator correction
    • Kyoto, Japan, abstract 442
    • Porter DA, Mueller E. Multi-shot diffusion-weighted EPI with readout mosaic segmentation and 2D navigator correction. In: Proceedings of the 12th Annual Meeting of ISMRM, Kyoto, Japan, 2004. (abstract 442).
    • (2004) Proceedings of the 12th Annual Meeting of ISMRM
    • Porter, D.A.1    Mueller, E.2
  • 21
    • 0030090119 scopus 로고    scopus 로고
    • Theoretical and experimental evaluation of phase-dispersion effects caused by brain motion in diffusion and perfusion MR imaging
    • Wirestam R, Greitz D, Thomsen C, Brockstedt S, Olsson MB, Stahlberg F. Theoretical and experimental evaluation of phase-dispersion effects caused by brain motion in diffusion and perfusion MR imaging. J Magn Reson Imaging 1996;6:348-355.
    • (1996) J Magn Reson Imaging , vol.6 , pp. 348-355
    • Wirestam, R.1    Greitz, D.2    Thomsen, C.3    Brockstedt, S.4    Olsson, M.B.5    Stahlberg, F.6
  • 22
    • 25144471800 scopus 로고    scopus 로고
    • Investigations on the efficiency of cardiac-gated methods for the acquisition of diffusion-weighted images
    • Nunes RG, Jezzard P, Clare S. Investigations on the efficiency of cardiac-gated methods for the acquisition of diffusion-weighted images. J Magn Reson 2005;177:102-110.
    • (2005) J Magn Reson , vol.177 , pp. 102-110
    • Nunes, R.G.1    Jezzard, P.2    Clare, S.3
  • 23
    • 0005589829 scopus 로고    scopus 로고
    • The use of intelligent re-acquisition to reduce scan time in MRI degraded by motion
    • Sydney, Australia, abstract 134
    • Nguyen Q, Clemence M, Ordidge RJ. The use of intelligent re-acquisition to reduce scan time in MRI degraded by motion. In: Proceedings of the 6th Annual Meeting of ISMRM, Sydney, Australia, 1998. (abstract 134).
    • (1998) Proceedings of the 6th Annual Meeting of ISMRM
    • Nguyen, Q.1    Clemence, M.2    Ordidge, R.J.3
  • 24
    • 0001871551 scopus 로고    scopus 로고
    • Isotropic diffusion-weighted multishot imaging using automatic reacquisition
    • Philadelphia, Pennsylvania, USA, abstract 559
    • Nguyen Q, Clemence M, Thornton J, Ordidge RJ. Isotropic diffusion-weighted multishot imaging using automatic reacquisition. In: Proceedings of the 7th Annual Meeting of ISMRM, Philadelphia, Pennsylvania, USA, 1999. (abstract 559).
    • (1999) Proceedings of the 7th Annual Meeting of ISMRM
    • Nguyen, Q.1    Clemence, M.2    Thornton, J.3    Ordidge, R.J.4
  • 25
    • 67749121724 scopus 로고    scopus 로고
    • Multi-shot, diffusion-weighted imaging at 3T using readout-segmented EPI and GRAPPA
    • Seattle, Washington, USA, abstract 1046
    • Porter DA, Heidemann RM. Multi-shot, diffusion-weighted imaging at 3T using readout-segmented EPI and GRAPPA. In: Proceedings of the 14th Annual Meeting of ISMRM, Seattle, Washington, USA, 2006. (abstract 1046).
    • (2006) Proceedings of the 14th Annual Meeting of ISMRM
    • Porter, D.A.1    Heidemann, R.M.2
  • 26
    • 67749092668 scopus 로고    scopus 로고
    • 2D-navigator-based re-acquisition for motion artefact suppression in multi-shot, diffusion-weighted imaging
    • Seattle, Washington, USA, abstract 1047
    • Porter DA. 2D-navigator-based re-acquisition for motion artefact suppression in multi-shot, diffusion-weighted imaging. In: Proceedings of the 14th Annual Meeting of ISMRM, Seattle, Washington, USA, 2006. (abstract 1047).
    • (2006) Proceedings of the 14th Annual Meeting of ISMRM
    • Porter, D.A.1
  • 31
    • 27944489525 scopus 로고    scopus 로고
    • Reconstruction as a source of artifact in non-gated single-shot diffusion-weighted EPI
    • Robson MD, Porter DA. Reconstruction as a source of artifact in non-gated single-shot diffusion-weighted EPI. Magn Reson Imaging 2005;23:899-905.
    • (2005) Magn Reson Imaging , vol.23 , pp. 899-905
    • Robson, M.D.1    Porter, D.A.2
  • 32
    • 66249114157 scopus 로고    scopus 로고
    • Trajectory Measurement and Generalised Reconstruction in Rectilinear EPI
    • Denver, Colorado, USA, abstract 1517
    • Josephs O, Deichmann R, Turner R. Trajectory Measurement and Generalised Reconstruction in Rectilinear EPI. In: Proceedings of the 8th Annual Meeting of ISMRM, Denver, Colorado, USA, 2000. (abstract 1517).
    • (2000) Proceedings of the 8th Annual Meeting of ISMRM
    • Josephs, O.1    Deichmann, R.2    Turner, R.3
  • 33
    • 0032754594 scopus 로고    scopus 로고
    • Motion correction with PROPELLER MRI: Application to head motion and free-breathing cardiac imaging
    • Pipe J. Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging. Magn Reson Med 1999;42:963-969.
    • (1999) Magn Reson Med , vol.42 , pp. 963-969
    • Pipe, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.