메뉴 건너뛰기




Volumn 4, Issue , 2009, Pages

Stereotactic body radiotherapy for stage I lung cancer and small lung metastasis: Evaluation of an immobilization system for suppression of respiratory tumor movement and preliminary results

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; BREATH HOLDING; CANCER CONTROL; CANCER INHIBITION; CANCER STAGING; DISEASE SEVERITY; FEMALE; FLUOROSCOPY; HUMAN; IMMOBILIZATION; LUNG CANCER; LUNG NON SMALL CELL CANCER; MAJOR CLINICAL STUDY; MALE; METASTASIS POTENTIAL; OUTCOME ASSESSMENT; OVERALL SURVIVAL; OXYGEN SATURATION; PATIENT COMPLIANCE; RADIATION DOSE; RADIATION PNEUMONIA; STEREOTACTIC BODY RADIATION THERAPY; TREATMENT RESPONSE; BREATHING MECHANICS; CLINICAL TRIAL; COMPUTER ASSISTED RADIOTHERAPY; EXERCISE; INSTRUMENTATION; LUNG TUMOR; METHODOLOGY; MIDDLE AGED; MOTION; PATHOLOGY; RADIOSURGERY;

EID: 67651243799     PISSN: None     EISSN: 1748717X     Source Type: Journal    
DOI: 10.1186/1748-717X-4-15     Document Type: Article
Times cited : (46)

References (23)
  • 1
    • 0032521265 scopus 로고    scopus 로고
    • Focal, high dose, and fractionated modified stereotactic radiation therapy for lung carcinoma patients: A preliminary experience
    • 10.1002/(SICI)1097-0142(19980315)82:6<1062::AID-CNCR8>3.0.CO;2-G 9506350
    • Uematsu M Shioda A Tahara K Fukui T Yamamoto F Tsumatori G Ozeki Y Aoki T Watanabe M Kusano S Focal, high dose, and fractionated modified stereotactic radiation therapy for lung carcinoma patients: A preliminary experience Cancer 1998, 82:1062-1070. 10.1002/ (SICI)1097-0142(19980315)82:6<1062::AID-CNCR8>3.0.CO;2-G 9506350
    • (1998) Cancer , vol.82 , pp. 1062-1070
    • Uematsu, M.1    Shioda, A.2    Tahara, K.3    Fukui, T.4    Yamamoto, F.5    Tsumatori, G.6    Ozeki, Y.7    Aoki, T.8    Watanabe, M.9    Kusano, S.10
  • 2
    • 0035500881 scopus 로고    scopus 로고
    • Computed tomography-guided frameless stereotactic radiotherapy for stage I non-small-cell lung cancer: A 5-year experience
    • 11597807
    • Uematsu M Shioda A Suda A Fukui T Ozeki Y Hama Y Wong JR Kusano S Computed tomography-guided frameless stereotactic radiotherapy for stage I non-small-cell lung cancer: A 5-year experience Int J Radiat Oncol Biol Phys 2001, 51:666-670. 11597807
    • (2001) Int J Radiat Oncol Biol Phys , vol.51 , pp. 666-670
    • Uematsu, M.1    Shioda, A.2    Suda, A.3    Fukui, T.4    Ozeki, Y.5    Hama, Y.6    Wong, J.R.7    Kusano, S.8
  • 5
    • 0035879542 scopus 로고    scopus 로고
    • Dosimetric evaluation of lung tumor immobilization using breath hold at deep inspiration
    • 10.1016/S0360-3016(01)01592-9 11429237
    • Barnes EA Murray BR Robinson DM Underwood LJ Hanson J Roa WHY Dosimetric evaluation of lung tumor immobilization using breath hold at deep inspiration Int J Radiat Oncol Biol Phys 2001, 50:1091-1098. 10.1016/ S0360-3016(01)01592-9 11429237
    • (2001) Int J Radiat Oncol Biol Phys , vol.50 , pp. 1091-1098
    • Barnes, E.A.1    Murray, B.R.2    Robinson, D.M.3    Underwood, L.J.4    Hanson, J.5    Roa, W.H.Y.6
  • 6
    • 0035879442 scopus 로고    scopus 로고
    • The effectiveness of an immobilization device in conformal radiotherapy for lung tumor: Reduction of respiratory tumor movement and evaluation of the daily setup accuracy
    • 10.1016/S0360-3016(01)01516-4 11429216
    • Negoro Y Nagata Y Aoki T Mizowaki T Araki N Takayama K Kokubo M Yano S Koga S Sasaki K Shibamoto Y Hiraoka M The effectiveness of an immobilization device in conformal radiotherapy for lung tumor:rEduction of respiratory tumor movement and evaluation of the daily setup accuracy Int J Radiat Oncol Biol Phys 2001, 50:889-898. 10.1016/ S0360-3016(01)01516-4 11429216
    • (2001) Int J Radiat Oncol Biol Phys , vol.50 , pp. 889-898
    • Negoro, Y.1    Nagata, Y.2    Aoki, T.3    Mizowaki, T.4    Araki, N.5    Takayama, K.6    Kokubo, M.7    Yano, S.8    Koga, S.9    Sasaki, K.10    Shibamoto, Y.11    Hiraoka, M.12
  • 7
    • 1342322799 scopus 로고    scopus 로고
    • Repositioning accuracy of a commercially available double-vacuum whole body immobilization system for stereotactic body radiation therapy
    • 14750894
    • Fuss M Salter BJ Rassiah P Cheek D Cavanaugh SX Herman TS Repositioning accuracy of a commercially available double-vacuum whole body immobilization system for stereotactic body radiation therapy Technol Cancer Res Treat 2004, 3:59-67. 14750894
    • (2004) Technol Cancer Res Treat , vol.3 , pp. 59-67
    • Fuss, M.1    Salter, B.J.2    Rassiah, P.3    Cheek, D.4    Cavanaugh, S.X.5    Herman, T.S.6
  • 9
    • 0037249948 scopus 로고    scopus 로고
    • Portal imaging to assess set-up errors, tumor motion and tumor shrinkage during conformal radiotherapy of non-small cell lung cancer
    • 10.1016/S0167-8140(02)00287-6 12559524
    • Erridge SC Seppenwoolde Y Muller SH van Herk M De Jaeger K Belderbos JSA Boersma LJ Lebesque JV Portal imaging to assess set-up errors, tumor motion and tumor shrinkage during conformal radiotherapy of non-small cell lung cancer Radiother Oncol 2003, 66:75-85. 10.1016/ S0167-8140(02)00287-6 12559524
    • (2003) Radiother Oncol , vol.66 , pp. 75-85
    • Erridge, S.C.1    Seppenwoolde, Y.2    Muller, S.H.3    van Herk, M.4    De Jaeger, K.5    Belderbos, J.S.A.6    Boersma, L.J.7    Lebesque, J.V.8
  • 10
    • 0031870905 scopus 로고    scopus 로고
    • What margin should be added to the clinical target volume in radiotherapy treatment planning for lung cancer?
    • 10.1016/S0167-8140(98)00046-2 9756174
    • Ekberg L Holmberg O Wittgren L Bjelkengren G Landberg T What margin should be added to the clinical target volume in radiotherapy treatment planning for lung cancer? Radiother Oncol 1998, 48:71-77. 10.1016/ S0167-8140(98)00046-2 9756174
    • (1998) Radiother Oncol , vol.48 , pp. 71-77
    • Ekberg, L.1    Holmberg, O.2    Wittgren, L.3    Bjelkengren, G.4    Landberg, T.5
  • 11
    • 0042591561 scopus 로고    scopus 로고
    • The use of the multislice CT for the determination of respiratory lung tumor movement in stereotactic single-dose irradiation
    • 10.1007/s00066-003-1070-8 14509953
    • Hof H Herfarth KK Münter M Essig M Wannenmacher M Debus J The use of the multislice CT for the determination of respiratory lung tumor movement in stereotactic single-dose irradiation Strahlenther Onkol 2003, 179:542-547. 10.1007/s00066-003-1070-8 14509953
    • (2003) Strahlenther Onkol , vol.179 , pp. 542-547
    • Hof, H.1    Herfarth, K.K.2    Münter, M.3    Essig, M.4    Wannenmacher, M.5    Debus, J.6
  • 12
    • 0038300496 scopus 로고    scopus 로고
    • Tumor location cannot predict the mobility of lung tumors: A 3D analysis of data generated from multiple CT scans
    • 10.1016/S0360-3016(02)04467-X 12738308
    • van Söernsen de Koste JR Lagerwaard FJ Nijssen-Visser MRJ Graveland WJ Senan S Tumor location cannot predict the mobility of lung tumors: A 3D analysis of data generated from multiple CT scans Int J Radiat Oncol Biol Phys 2003, 56:348-354. 10.1016/S0360-3016(02)04467-X 12738308
    • (2003) Int J Radiat Oncol Biol Phys , vol.56 , pp. 348-354
    • van Söernsen de Koste, J.R.1    Lagerwaard, F.J.2    Nijssen-Visser, M.R.J.3    Graveland, W.J.4    Senan, S.5
  • 19
    • 0842285322 scopus 로고    scopus 로고
    • Reproducibility of patient positioning for fractionated extracranial stereotactic radiotherapy using a double-vacuum technique
    • 10.1007/s00066-004-1146-0 14762665
    • Nevinny-Stickel M Sweeney RA Bale RJ Posch A Auberger T Lukas P Reproducibility of patient positioning for fractionated extracranial stereotactic radiotherapy using a double-vacuum technique Strahlenther Onkol 2004, 180:117-122. 10.1007/s00066-004-1146-0 14762665
    • (2004) Strahlenther Onkol , vol.180 , pp. 117-122
    • Nevinny-Stickel, M.1    Sweeney, R.A.2    Bale, R.J.3    Posch, A.4    Auberger, T.5    Lukas, P.6
  • 20
  • 23
    • 39049164591 scopus 로고    scopus 로고
    • Outcomes of risk-adapted fractionated stereotactic radiotherapy for stage I non-small-cell lung cancer
    • 18164849
    • Lagerwaard FJ Haasbeek CJ Smit EF Slotman BJ Senan S Outcomes of risk-adapted fractionated stereotactic radiotherapy for stage I non-small-cell lung cancer Int J Radiat Oncol Biol Phys 2008, 70:685-692. 18164849
    • (2008) Int J Radiat Oncol Biol Phys , vol.70 , pp. 685-692
    • Lagerwaard, F.J.1    Haasbeek, C.J.2    Smit, E.F.3    Slotman, B.J.4    Senan, S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.