메뉴 건너뛰기




Volumn 24, Issue 3, 2009, Pages 325-333

Improving outcomes through the use of surgical sealants for anastomotic sealing during cardiovascular surgery: Review articles

Author keywords

[No Author keywords available]

Indexed keywords

2 OCTYL CYANOACRYLATE; ADHESIVE AGENT; ANTICOAGULANT AGENT; ANTITHROMBOCYTIC AGENT; APROTININ; COLLAGEN; ENBUCRILATE; EVICEL; FIBRIN GLUE; FIBRINOGEN; FLOSEAL; FORMALDEHYDE; GELATIN; GELFOAM; GLUTARALDEHYDE; HELISTAT; HELITENE; HEMOSTATIC AGENT; INSTAT; MICROCRYSTALLINE COLLAGEN; NU KNIT; OXIDIZED REGENERATED CELLULOSE; RESORCINOL; SEALANT; STEROID; THROMBIN; TISSUE ADHESIVE; UNCLASSIFIED DRUG; VITAGEL;

EID: 67651180921     PISSN: 08860440     EISSN: 15408191     Source Type: Journal    
DOI: 10.1111/j.1540-8191.2009.00809.x     Document Type: Review
Times cited : (19)

References (41)
  • 1
    • 8444229803 scopus 로고    scopus 로고
    • The use of local agents: Surgicel and surgifoam
    • Sabel M, Stummer W : The use of local agents: Surgicel and surgifoam. Eur Spine J 2004 13 (Suppl 1 S97 101.
    • (2004) Eur Spine J , vol.13 , Issue.SUPPL. 1 , pp. 97-101
    • Sabel, M.1    Stummer, W.2
  • 2
    • 17944383029 scopus 로고    scopus 로고
    • A multicenter, prospective, randomized trial evaluation a new hemostatic agent for spinal surgery
    • Renkens KL, Payner PD, Leipzig TJ, et al : A multicenter, prospective, randomized trial evaluation a new hemostatic agent for spinal surgery. Spine 2001 26 : 1645 1650.
    • (2001) Spine , vol.26 , pp. 1645-1650
    • Renkens, K.L.1    Payner, P.D.2    Leipzig, T.J.3    Al, E.4
  • 3
    • 33747150062 scopus 로고    scopus 로고
    • Transfusion-related acute lung injury (TRALI): Current clinical and pathophysiologic considerations
    • Swanson K, Dwyer DM, Krochmal J, et al : Transfusion-related acute lung injury (TRALI): Current clinical and pathophysiologic considerations. Lung 2006 184 : 177 185.
    • (2006) Lung , vol.184 , pp. 177-185
    • Swanson, K.1    Dwyer, D.M.2    Krochmal, J.3    Al, E.4
  • 4
    • 19744373535 scopus 로고    scopus 로고
    • Risks of blood transfusion
    • Goodnough LT : Risks of blood transfusion. Anesthesiol Clin N Am 2005 23 : 241 252.
    • (2005) Anesthesiol Clin N Am , vol.23 , pp. 241-252
    • Goodnough, L.T.1
  • 5
    • 0034945280 scopus 로고    scopus 로고
    • Herbal medicines and perioperative care
    • Ang-Lee MK, Moss J, Yuan C : Herbal medicines and perioperative care. J Am Med Assoc 2001 286 (2 208 216.
    • (2001) J Am Med Assoc , vol.286 , Issue.2 , pp. 208-216
    • Ang-Lee, M.K.1    Moss, J.2    Yuan, C.3
  • 6
    • 34548300664 scopus 로고    scopus 로고
    • Absorbable hemostatic agents
    • Gabay M : Absorbable hemostatic agents. AJHP 2006 63 : 1244 1253.
    • (2006) AJHP , vol.63 , pp. 1244-1253
    • Gabay, M.1
  • 7
    • 26844490565 scopus 로고    scopus 로고
    • Clinical benefits and risk analysis of topical hemostats: A review
    • Tomizawa Y : Clinical benefits and risk analysis of topical hemostats: A review. J Artif Organs 2005 8 : 137 142.
    • (2005) J Artif Organs , vol.8 , pp. 137-142
    • Tomizawa, Y.1
  • 12
    • 67651170568 scopus 로고    scopus 로고
    • Johnson & Johnson. Somerville, NJ
    • Instat [Instructions for Use]. Johnson & Johnson, Somerville, NJ, 2007.
    • (2007) Instat [instructions for Use].
  • 13
    • 67651175236 scopus 로고    scopus 로고
    • Integra Lifesciences Corporation. Plainsboro, NJ
    • Helistat/Helitene [Instructions for Use]. Integra Lifesciences Corporation, Plainsboro, NJ, 2007.
    • (2007) Helistat/Helitene [instructions for Use].
  • 17
    • 0034855988 scopus 로고    scopus 로고
    • New paradigms and improved results for the surgical treatment of acute type A dissection
    • Bavaria JE, Pochettino A, Brinster DR, et al : New paradigms and improved results for the surgical treatment of acute type A dissection. Ann Surg 2001 234 (3 336 343.
    • (2001) Ann Surg , vol.234 , Issue.3 , pp. 336-343
    • Bavaria, J.E.1    Pochettino, A.2    Brinster, D.R.3    Al, E.4
  • 18
    • 0345688633 scopus 로고    scopus 로고
    • BioGlue: Albumin/glutaraldehyde sealant in cardiac surgery
    • Chao H, Torchiana DF : BioGlue: Albumin/glutaraldehyde sealant in cardiac surgery. J Card Surg 2003 18 : 500 503.
    • (2003) J Card Surg , vol.18 , pp. 500-503
    • Chao, H.1    Torchiana, D.F.2
  • 19
    • 18144423828 scopus 로고    scopus 로고
    • Release of glutaraldehyde from an albumin-glutaraldehyde tissue adhesive causes significant in vitro and in vivo toxicity
    • Fürst W, Banerjee A : Release of glutaraldehyde from an albumin-glutaraldehyde tissue adhesive causes significant in vitro and in vivo toxicity. Ann Thorac Surg 2005 79 : 1522 1528.
    • (2005) Ann Thorac Surg , vol.79 , pp. 1522-1528
    • Fürst, W.1    Banerjee, A.2
  • 23
    • 0141459701 scopus 로고    scopus 로고
    • N-2-butyl-cyanoacrylate for bleeding gastric varices: A United States pilot study and cost analysis
    • Greenwald BD, Caldwell SH, Hespenheide EE, et al : N-2-butyl- cyanoacrylate for bleeding gastric varices: A United States pilot study and cost analysis. Am J Gastroenterol 2003 98 : 1982 1988.
    • (2003) Am J Gastroenterol , vol.98 , pp. 1982-1988
    • Greenwald, B.D.1    Caldwell, S.H.2    Hespenheide, E.E.3    Al, E.4
  • 24
    • 33846386514 scopus 로고    scopus 로고
    • Prospective randomized study evaluating an absorbable cyanoacrylate for use in vascular reconstructions
    • Closure Medical Surgical Sealant Study Group
    • Lumsden AB, Heyman ER, Closure Medical Surgical Sealant Study Group : Prospective randomized study evaluating an absorbable cyanoacrylate for use in vascular reconstructions. J Vasc Surg 2006 44 : 1002 1009.
    • (2006) J Vasc Surg , vol.44 , pp. 1002-1009
    • Lumsden, A.B.1    Heyman, E.R.2
  • 25
    • 67650772422 scopus 로고    scopus 로고
    • Protein polymers
    • In. Quinn, J.V. ed. B.C. Decker, Inc. Hamilton, ON. p.
    • Yuksel KU : Protein polymers. In Quinn JV (ed Tissue Adhesives in Clinical Medicine. B.C. Decker, Inc, Hamilton, ON, 2004, p. 113.
    • (2004) Tissue Adhesives in Clinical Medicine. , pp. 113
    • Yuksel, K.U.1
  • 26
    • 67651161234 scopus 로고    scopus 로고
    • Baxter Healthcare. Westlake Village, CA
    • Tisseel [Package Insert]. Baxter Healthcare, Westlake Village, CA, 2007.
    • (2007) Tisseel [package Insert].
  • 27
    • 32644434328 scopus 로고    scopus 로고
    • Hemostatic agents and tissue glues in urologic injuries and wound healing
    • Evans LA, Morey AF : Hemostatic agents and tissue glues in urologic injuries and wound healing. Urol Clin N Am 2006 33 : 1 12.
    • (2006) Urol Clin N Am , vol.33 , pp. 1-12
    • Evans, L.A.1    Morey, A.F.2
  • 28
    • 67651182987 scopus 로고    scopus 로고
    • Johnson & Johnson. Somerville, NJ
    • Evicel [Package Insert]. Johnson & Johnson, Somerville, NJ, 2006.
    • (2006) Evicel [package Insert].
  • 29
    • 0038038285 scopus 로고    scopus 로고
    • The safety of fibrin sealants
    • Joch C. The safety of fibrin sealants. Cardiovasc Surg 2003 11 (S1 23 28.
    • (2003) Cardiovasc Surg , vol.11 , Issue.S1 , pp. 23-28
    • Joch, C.1
  • 30
    • 67651173686 scopus 로고    scopus 로고
    • Baxter Healthcare. Westlake Village, CA
    • Coseal [Instructions for Use]. Baxter Healthcare, Westlake Village, CA, 2006.
    • (2006) Coseal [instructions for Use].
  • 31
    • 67651179945 scopus 로고    scopus 로고
    • Confluent Surgical, Inc. Waltham, MA
    • DuraSeal [Package Insert]. Confluent Surgical, Inc, Waltham, MA, 2006.
    • (2006) DuraSeal [package Insert].
  • 32
    • 20544468247 scopus 로고    scopus 로고
    • The threat of adhesive embolization: BioGlue leaks through needle holes in aortic tissue and prosthetic grafts
    • discussion 110-101.
    • LeMaire SA, Carter SA, Won T, Wang X, Conklin LD, Coselli JS : The threat of adhesive embolization: BioGlue leaks through needle holes in aortic tissue and prosthetic grafts. Ann Thorac Surg 2005 80 : 106 110 discussion 110-101.
    • (2005) Ann Thorac Surg , vol.80 , pp. 106-110
    • Lemaire, S.A.1    Carter, S.A.2    Won, T.3    Wang, X.4    Conklin, L.D.5    Coselli, J.S.6
  • 33
    • 4444384157 scopus 로고    scopus 로고
    • Embolus of surgical adhesive to the extremities causing acute ischemia: Report of two cases
    • Guerrero MA, Cox M, Lumsden AB, Reardon M, Howell J : Embolus of surgical adhesive to the extremities causing acute ischemia: Report of two cases. J Vasc Surg 2004 40 : 571 573.
    • (2004) J Vasc Surg , vol.40 , pp. 571-573
    • Guerrero, M.A.1    Cox, M.2    Lumsden, A.B.3    Reardon, M.4    Howell, J.5
  • 34
    • 34548132114 scopus 로고    scopus 로고
    • Use of bovine albumin-glutaraldehyde glue in cardiovascular surgery
    • Zehr KJ : Use of bovine albumin-glutaraldehyde glue in cardiovascular surgery. Ann Thorac Surg 2007 84 : 1048 1052.
    • (2007) Ann Thorac Surg , vol.84 , pp. 1048-1052
    • Zehr, K.J.1
  • 35
    • 0038798476 scopus 로고    scopus 로고
    • Surgical sealant in the prevention of early vein graft injury in an ex vivo model
    • Stooker W, Niessen HW, Jansen EK, et al : Surgical sealant in the prevention of early vein graft injury in an ex vivo model. Cardiovasc Pathol 2003 12 (4 202 206.
    • (2003) Cardiovasc Pathol , vol.12 , Issue.4 , pp. 202-206
    • Stooker, W.1    Niessen, H.W.2    Jansen, E.K.3    Al, E.4
  • 37
    • 0034801735 scopus 로고    scopus 로고
    • A tissue sealant based on reactive multifunctional polyethylene glycol
    • Wallace DG, Cruise GM, Rhee WM, et al : A tissue sealant based on reactive multifunctional polyethylene glycol. J Biomed Mater Res 2001 58 : 545 555.
    • (2001) J Biomed Mater Res , vol.58 , pp. 545-555
    • Wallace, D.G.1    Cruise, G.M.2    Rhee, W.M.3    Al, E.4
  • 38
    • 0034794185 scopus 로고    scopus 로고
    • Evaluation of a novel synthetic sealant for inhibition of cardiac adhesions and clinical experience in cardiac surgery procedures
    • Hendrikx M, Mees U, Hill AC, Egbert B, Coker GT, Estridge TD : Evaluation of a novel synthetic sealant for inhibition of cardiac adhesions and clinical experience in cardiac surgery procedures. Heart Surg Forum 2001 4 : 204 210.
    • (2001) Heart Surg Forum , vol.4 , pp. 204-210
    • Hendrikx, M.1    Mees, U.2    Hill, A.C.3    Egbert, B.4    Coker, G.T.5    Estridge, T.D.6
  • 39
    • 0141786599 scopus 로고    scopus 로고
    • Reducing the incidence and severity of pericardial adhesions with a sprayable polymeric matrix
    • Konertz WF, Kostelka M, Mohr FW, et al : Reducing the incidence and severity of pericardial adhesions with a sprayable polymeric matrix. Ann Thorac Surg 2003 76 : 1270 1274.
    • (2003) Ann Thorac Surg , vol.76 , pp. 1270-1274
    • Konertz, W.F.1    Kostelka, M.2    Mohr, F.W.3    Al, E.4
  • 40
  • 41
    • 0036266279 scopus 로고    scopus 로고
    • BioGlue surgical adhesive impairs aortic growth and causes anastomotic strictures
    • LeMaire SA, Schmittling ZC, Coselli JS, et al : BioGlue surgical adhesive impairs aortic growth and causes anastomotic strictures. Ann Thorac Surg 2002 73 (5 1500 1505.
    • (2002) Ann Thorac Surg , vol.73 , Issue.5 , pp. 1500-1505
    • Lemaire, S.A.1    Schmittling, Z.C.2    Coselli, J.S.3    Al, E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.