메뉴 건너뛰기




Volumn 18, Issue 5, 2009, Pages 382-387

Fatigue and fluoride corrosion on streptococcus mutans adherence to titanium-based implant/component surfaces

Author keywords

Bacterial adhesion; Corrosion; Dental implants; Fluoride

Indexed keywords

ANTICARIES AGENT; BIOMEDICAL AND DENTAL MATERIALS; FLUORIDE; TITANIUM;

EID: 67651089882     PISSN: 1059941X     EISSN: 1532849X     Source Type: Journal    
DOI: 10.1111/j.1532-849X.2009.00463.x     Document Type: Article
Times cited : (45)

References (28)
  • 1
    • 0036210742 scopus 로고    scopus 로고
    • Influence of fluoride content and pH on the corrosion resistance of titanium and its alloys
    • Schiff N, Grosgogeat B, Lissac M, et al : Influence of fluoride content and pH on the corrosion resistance of titanium and its alloys. Biomaterials 2002 23 : 1995 2002
    • (2002) Biomaterials , vol.23 , pp. 1995-2002
    • Schiff, N.1    Grosgogeat, B.2    Lissac, M.3
  • 2
    • 60649098078 scopus 로고    scopus 로고
    • Materials used in implantology
    • In. O'Brien, W.J. ed. Chicago. Quintessence. pp.
    • O'Brien WJ : Materials used in implantology. In O'Brien WJ (ed Dental Materials and Their Selection, Vol 1 (ed 2). Chicago, Quintessence, 1997, pp. 320 324
    • (1997) Dental Materials and Their Selection , vol.12 , pp. 320-324
    • O'Brien, W.J.1
  • 3
    • 0030155880 scopus 로고    scopus 로고
    • In vivo measurements of some functional aspects with mandibular fixed prostheses supported by implants
    • Mericske-Stern R, Zarb GA : In vivo measurements of some functional aspects with mandibular fixed prostheses supported by implants. Clin Oral Implants Res 1996 7 : 153 161
    • (1996) Clin Oral Implants Res , vol.7 , pp. 153-161
    • Mericske-Stern, R.1    Zarb, G.A.2
  • 4
    • 0036885837 scopus 로고    scopus 로고
    • Fatigue resistance of two implant/abutment joint designs
    • Khraisat A, Stegaroiu R, Nomura S, et al : Fatigue resistance of two implant/abutment joint designs. J Prosthet Dent 2002 88 : 604 610
    • (2002) J Prosthet Dent , vol.88 , pp. 604-610
    • Khraisat, A.1    Stegaroiu, R.2    Nomura, S.3
  • 5
    • 67651109479 scopus 로고
    • Wide diameter implants: Indications, considerations and preliminary results over a two-year period
    • Graves SL, Jansen CE, Siddiqui AA, et al : Wide diameter implants: indications, considerations and preliminary results over a two-year period. Aust Prosthodont J 1992 7 : 353 359
    • (1992) Aust Prosthodont J , vol.7 , pp. 353-359
    • Graves, S.L.1    Jansen, C.E.2    Siddiqui, A.A.3
  • 6
    • 0038167504 scopus 로고    scopus 로고
    • In vitro corrosion behavior of bioceramic, metallic and bioceramic-metallic coated stainless steel dental implants
    • Fathi MH, Salehi M, Saatchi A, et al : In vitro corrosion behavior of bioceramic, metallic and bioceramic-metallic coated stainless steel dental implants. Dent Mater 2003 19 : 188 198
    • (2003) Dent Mater , vol.19 , pp. 188-198
    • Fathi, M.H.1    Salehi, M.2    Saatchi, A.3
  • 7
    • 0029685412 scopus 로고    scopus 로고
    • Corrosive properties of fluoride containing odontologic gels against titanium
    • Toumelin-Chemla F, Rouellet F, Burdairon G : Corrosive properties of fluoride containing odontologic gels against titanium. J Dent 1996 24 : 109 115
    • (1996) J Dent , vol.24 , pp. 109-115
    • Toumelin-Chemla, F.1    Rouellet, F.2    Burdairon, G.3
  • 9
    • 0034910625 scopus 로고    scopus 로고
    • The corrosion resistance of pure titanium in organic acids
    • Koike M, Fujii H : The corrosion resistance of pure titanium in organic acids. Biomaterials 2001 22 : 2931 2936
    • (2001) Biomaterials , vol.22 , pp. 2931-2936
    • Koike, M.1    Fujii, H.2
  • 10
    • 0036027441 scopus 로고    scopus 로고
    • Effects of fluoride concentration and elastic tensile strain on the corrosion resistance of commercially pure titanium
    • Huang HH : Effects of fluoride concentration and elastic tensile strain on the corrosion resistance of commercially pure titanium. Biomaterials 2002 23 : 59 63
    • (2002) Biomaterials , vol.23 , pp. 59-63
    • Huang, H.H.1
  • 11
    • 0031864346 scopus 로고    scopus 로고
    • Effects of fluoride on titanium and other dental alloys in dentistry
    • Reclaru L, Meyer JM : Effects of fluoride on titanium and other dental alloys in dentistry. Biomaterials 1998 19 : 85 92
    • (1998) Biomaterials , vol.19 , pp. 85-92
    • Reclaru, L.1    Meyer, J.M.2
  • 12
    • 33644803496 scopus 로고    scopus 로고
    • Influence of fluoride, hydrogen peroxide and lactic acid on the corrosion resistance of commercially pure titanium
    • Mabilleau G, Bourdon S, Joly-Guillou ML, et al : Influence of fluoride, hydrogen peroxide and lactic acid on the corrosion resistance of commercially pure titanium. Acta Biomaterialia 2006 2 : 121 129
    • (2006) Acta Biomaterialia , vol.2 , pp. 121-129
    • Mabilleau, G.1    Bourdon, S.2    Joly-Guillou, M.L.3
  • 13
    • 0031002425 scopus 로고    scopus 로고
    • The effect of surface roughness on early in vivo plaque colonization on titanium
    • Rimondini L, Fare S, Brambilla E, et al : The effect of surface roughness on early in vivo plaque colonization on titanium. J Periodontol 1997 68 : 556 562
    • (1997) J Periodontol , vol.68 , pp. 556-562
    • Rimondini, L.1    Fare, S.2    Brambilla, E.3
  • 14
    • 0034942733 scopus 로고    scopus 로고
    • The effects of surface roughness and type of denture acrylic on biofilm formation by Streptococcus oralis in a constant depth film fermenter
    • Morgan TD, Wilson M : The effects of surface roughness and type of denture acrylic on biofilm formation by Streptococcus oralis in a constant depth film fermenter. J Appl Microbiol 2001 91 : 47 53
    • (2001) J Appl Microbiol , vol.91 , pp. 47-53
    • Morgan, T.D.1    Wilson, M.2
  • 15
    • 1642312001 scopus 로고    scopus 로고
    • A Bacterial adhesion on commercially pure titanium and zirconium oxide disks: An in vivo human study
    • Scarano A, Piattelli M, Caputi S, et al : A. Bacterial adhesion on commercially pure titanium and zirconium oxide disks: an in vivo human study. J Periodontol 2004 75 : 292 296
    • (2004) J Periodontol , vol.75 , pp. 292-296
    • Scarano, A.1    Piattelli, M.2    Caputi, S.3
  • 16
    • 0030224970 scopus 로고    scopus 로고
    • The influence of an abutment surface roughness on plaque accumulation and peri-implant mucositis
    • Bollen CML, Papaioannou W, Van Eldere J, et al : The influence of an abutment surface roughness on plaque accumulation and peri-implant mucositis. Clin Oral Implants Res 1996 7 : 201 211
    • (1996) Clin Oral Implants Res , vol.7 , pp. 201-211
    • Bollen, C.M.L.1    Papaioannou, W.2    Van Eldere, J.3
  • 17
    • 0026124943 scopus 로고
    • The effect of oral topical fluorides on the surface of commercially pure titanium
    • Siirilä HS, Könönen M : The effect of oral topical fluorides on the surface of commercially pure titanium. Int J Oral Maxillofac Implants 1991 6 : 50 54
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 50-54
    • Siirilä, H.S.1    Könönen, M.2
  • 18
    • 0034218915 scopus 로고    scopus 로고
    • Mechanics of the implant-abutment connection: An 8 degree taper compared to a butt joint connection
    • Merz BR, Hunenbart S, Belser UC : Mechanics of the implant-abutment connection: an 8 degree taper compared to a butt joint connection. Int J Oral Maxillofac Implants 2000 15 : 519 526
    • (2000) Int J Oral Maxillofac Implants , vol.15 , pp. 519-526
    • Merz, B.R.1    Hunenbart, S.2    Belser, U.C.3
  • 22
    • 60649118084 scopus 로고
    • EDS titanium
    • In. James, W.J. Straumanis, M.E. eds. New York. Marcel Dekker. pp.
    • Barjj A : EDS titanium. In James WJ, Straumanis ME (eds Encyclopedia of Electrochemistry of the Elements, Vol 5. New York, Marcel Dekker, 1976, pp. 305 395
    • (1976) Encyclopedia of Electrochemistry of the Elements , vol.5 , pp. 305-395
    • Barjj, A.1
  • 23
    • 0038532459 scopus 로고    scopus 로고
    • Fluoride concentration in saliva after use of oral hygiene products
    • Campus G, Lallai MR, Carboni R : Fluoride concentration in saliva after use of oral hygiene products. Caries Res 2003 37 : 66 70
    • (2003) Caries Res , vol.37 , pp. 66-70
    • Campus, G.1    Lallai, M.R.2    Carboni, R.3
  • 24
    • 0024233982 scopus 로고
    • Periodontal consideration of implants and implant associated microbiota
    • Newman MG, Fleming TF : Periodontal consideration of implants and implant associated microbiota. J Dent Educ 1988 52 : 737 744
    • (1988) J Dent Educ , vol.52 , pp. 737-744
    • Newman, M.G.1    Fleming, T.F.2
  • 25
    • 0022032459 scopus 로고
    • Long-term effects on chewing with mandibular fixed prostheses on osseointegrated implants
    • Lindquist LW, Carlsson GE : Long-term effects on chewing with mandibular fixed prostheses on osseointegrated implants. Acta Odontol Scand 1985 43 : 39 45
    • (1985) Acta Odontol Scand , vol.43 , pp. 39-45
    • Lindquist, L.W.1    Carlsson, G.E.2
  • 26
    • 0029440456 scopus 로고
    • Oral bacterial attachment to titanium surfaces: A scanning electron microscopy study
    • Wu-Yuan CD, Eganhouse KJ, Keller JC, et al : Oral bacterial attachment to titanium surfaces: a scanning electron microscopy study. J Oral Implantol 1995 21 : 207 213
    • (1995) J Oral Implantol , vol.21 , pp. 207-213
    • Wu-Yuan, C.D.1    Eganhouse, K.J.2    Keller, J.C.3
  • 27
    • 0023386602 scopus 로고
    • Adherence of Streptococcus mutans to implant materials
    • Fujioka-Hirai Y, Akagawa Y, Minagi S, et al : Adherence of Streptococcus mutans to implant materials. J Biomed Mater Res 1987 21 : 913 920
    • (1987) J Biomed Mater Res , vol.21 , pp. 913-920
    • Fujioka-Hirai, Y.1    Akagawa, Y.2    Minagi, S.3
  • 28
    • 60649095997 scopus 로고
    • Introduction
    • In. Donachie, M.J.Jr. ed. Materials Park, OH. ASM international. pp.
    • Donachie MJ Jr. : Introduction. In Donachie MJ Jr. (ed Titanium: A Technical Guide. Materials Park, OH, ASM international, 1987, pp. 9 19
    • (1987) Titanium: A Technical Guide. , pp. 9-19
    • Donachie, Jr.M.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.