1
-
-
0011802899
-
Reducing energy costs in vapor-compression refrigeration and air conditioning using liquid recycle-part 2: performance
-
No. 3222
-
Holtzapple M. Reducing energy costs in vapor-compression refrigeration and air conditioning using liquid recycle-part 2: performance. ASHRAE Trans. 95 1 (1989) 179-205 No. 3222
-
(1989)
ASHRAE Trans.
, vol.95
, Issue.1
, pp. 179-205
-
-
Holtzapple, M.1
-
2
-
-
0000748105
-
Study on scroll compressor behavior on case of liquid refrigerant injection
-
(in Japanese)
-
Hirano T., Hagimoto K., and Maysuda S. Study on scroll compressor behavior on case of liquid refrigerant injection. Trans. JAR 10 2 (1993) 227-238 (in Japanese)
-
(1993)
Trans. JAR
, vol.10
, Issue.2
, pp. 227-238
-
-
Hirano, T.1
Hagimoto, K.2
Maysuda, S.3
-
3
-
-
67651092514
-
High performance scroll compressor with liquid refrigerant injection
-
Compressor Eng. Conf, Purdue
-
H. Yamazaki, T. Itoh, T. Sato, H. Kobayashi, High performance scroll compressor with liquid refrigerant injection, in: Proc. of the Int. Compressor Eng. Conf., Purdue, 2002, p. C22-1.
-
(2002)
Proc. of the Int
-
-
Yamazaki, H.1
Itoh, T.2
Sato, T.3
Kobayashi, H.4
-
4
-
-
0037211454
-
Influence of liquid refrigerant injection on the performance of an inverter-driven scroll compressor
-
Cho H., Chung J.T., and Kim Y. Influence of liquid refrigerant injection on the performance of an inverter-driven scroll compressor. Int. J. Refrig. 26 (2003) 87-94
-
(2003)
Int. J. Refrig.
, vol.26
, pp. 87-94
-
-
Cho, H.1
Chung, J.T.2
Kim, Y.3
-
5
-
-
0036883468
-
Thermodynamic analysis on the performance of a variable speed scroll compressor with refrigerant injection
-
Park Y.C., Kim Y., and Cho H. Thermodynamic analysis on the performance of a variable speed scroll compressor with refrigerant injection. Int. J. Refrig. 25 (2002) 1072-1082
-
(2002)
Int. J. Refrig.
, vol.25
, pp. 1072-1082
-
-
Park, Y.C.1
Kim, Y.2
Cho, H.3
-
6
-
-
0035452618
-
An investigation of the performance of a scroll compressor under liquid refrigerant injection
-
Dutta A.K., Yanagisawa T., and Fukuta M. An investigation of the performance of a scroll compressor under liquid refrigerant injection. Int. J. Refrig. 24 (2001) 577-587
-
(2001)
Int. J. Refrig.
, vol.24
, pp. 577-587
-
-
Dutta, A.K.1
Yanagisawa, T.2
Fukuta, M.3
-
7
-
-
0036883490
-
Scroll compressors using gas and liquid injection: experimental analysis and modeling
-
Winandy E.L., and Lebrun J. Scroll compressors using gas and liquid injection: experimental analysis and modeling. Int. J. Refrig. 25 (2002) 1143-1156
-
(2002)
Int. J. Refrig.
, vol.25
, pp. 1143-1156
-
-
Winandy, E.L.1
Lebrun, J.2
-
8
-
-
0037211453
-
Experimental investigation of air source heat pump for cold regions
-
Ma G., Chai Q., and Jiang Y. Experimental investigation of air source heat pump for cold regions. Int. J. Refrig. 26 (2003) 12-18
-
(2003)
Int. J. Refrig.
, vol.26
, pp. 12-18
-
-
Ma, G.1
Chai, Q.2
Jiang, Y.3
-
9
-
-
0003284009
-
Liquid refrigerant injection in scroll compressors operating high compression ratios
-
S. Ayub, W.J. Bush, K.D. Haller, Liquid refrigerant injection in scroll compressors operating high compression ratios, in: Proc. of International Compressor Engineering Conference at Purdue, 1992, pp. 561-567.
-
(1992)
Proc. of International Compressor Engineering Conference at Purdue
, pp. 561-567
-
-
Ayub, S.1
Bush, W.J.2
Haller, K.D.3
-
10
-
-
16644378318
-
An implicit curve fitting method for thermodynamic refrigerant gas
-
(in Chinese)
-
Zhang C., Ding G., and Li H. An implicit curve fitting method for thermodynamic refrigerant gas. J. Eng. Thermophys. 21 (2000) 533-536 (in Chinese)
-
(2000)
J. Eng. Thermophys.
, vol.21
, pp. 533-536
-
-
Zhang, C.1
Ding, G.2
Li, H.3
-
11
-
-
33750602623
-
Fast calculation method for sub-cooled pure refrigerant thermodynamic properties
-
(in Chinese)
-
Long H., Ding G., and Wu Z. Fast calculation method for sub-cooled pure refrigerant thermodynamic properties. Fluid Machinery 34 (2006) 78-81 (in Chinese)
-
(2006)
Fluid Machinery
, vol.34
, pp. 78-81
-
-
Long, H.1
Ding, G.2
Wu, Z.3
|