메뉴 건너뛰기




Volumn 24, Issue 8, 2008, Pages 1182-1185

Construction of targeted ultrasound microbubbles with anti P-selectin monoclone antibody via streptavidin bridge and evaluation of its reliability using fluorescence in vitro

Author keywords

Fluorescence; P selectin; Targeted ultrasound microbubbles

Indexed keywords


EID: 67651026428     PISSN: 10033289     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (3)

References (8)
  • 1
    • 67651063776 scopus 로고    scopus 로고
    • Evaluation of renal tissue ischemia-reperfusion injury with microbbles targeted to P-selectin and contrast ultrasound
    • Chen S M, Yang L, Bin J P, et al. Evaluation of renal tissue ischemia-reperfusion injury with microbbles targeted to P-selectin and contrast ultrasound. Chin J Med Imaging Technol, 2008, 24(7): 985-987.
    • (2008) Chin J Med Imaging Technol , vol.24 , Issue.7 , pp. 985-987
    • Chen, S.M.1    Yang, L.2    Bin, J.P.3
  • 2
    • 0344527897 scopus 로고    scopus 로고
    • Avidin-biotin system for delivery of diagnostic agents
    • Sakahara H, Saga T. Avidin-biotin system for delivery of diagnostic agents. Adv Drug Deliv Rev, 1999, 37(1-3): 89-101.
    • (1999) Adv Drug Deliv Rev , vol.37 , Issue.1-3 , pp. 89-101
    • Sakahara, H.1    Saga, T.2
  • 3
    • 58149527724 scopus 로고    scopus 로고
    • Binding capability of microbubbles targeted to P-selsctin under physiologic flow conditions
    • Wu J F, Yang L, Bin J P, et al. Binding capability of microbubbles targeted to P-selsctin under physiologic flow conditions. Chin J Med Imaging Technol, 2008, 24(7): 981-984.
    • (2008) Chin J Med Imaging Technol , vol.24 , Issue.7 , pp. 981-984
    • Wu, J.F.1    Yang, L.2    Bin, J.P.3
  • 4
    • 34948901570 scopus 로고    scopus 로고
    • Targeted ultrasound contrast agent for molecular imaging of inflammation in high-shear flow
    • Klibanov A L, Rychak J J, Yang W C, et al. Targeted ultrasound contrast agent for molecular imaging of inflammation in high-shear flow. Contrast Media and Molecular Imaging, 2006, 1(6): 259-266.
    • (2006) Contrast Media and Molecular Imaging , vol.1 , Issue.6 , pp. 259-266
    • Klibanov, A.L.1    Rychak, J.J.2    Yang, W.C.3
  • 5
    • 34547396737 scopus 로고    scopus 로고
    • Ultrasound radiation force modulates ligand availability on targeted contrast agents
    • Borden M A, Sarantos M R, Stieger S M, et al. Ultrasound radiation force modulates ligand availability on targeted contrast agents. Mol Imaging, 2006, 5(3): 139-147.
    • (2006) Mol Imaging , vol.5 , Issue.3 , pp. 139-147
    • Borden, M.A.1    Sarantos, M.R.2    Stieger, S.M.3
  • 6
    • 33748201140 scopus 로고    scopus 로고
    • Deformable gas-filled microbubbles targeted to P-selectin
    • Rychak J J, Lindner J R, Ley k, et al. Deformable gas-filled microbubbles targeted to P-selectin. J Controlled Release,2006, 114(3): 288-299.
    • (2006) J Controlled Release , vol.114 , Issue.3 , pp. 288-299
    • Rychak, J.J.1    Lindner, J.R.2    Ley, K.3
  • 7
    • 0035940372 scopus 로고    scopus 로고
    • Ultrasound assessment of inflammation and renal tissue injury with microbubbles targeted to P-selectin
    • Lindner J R, Song J, Christiansen J, et al. Ultrasound assessment of inflammation and renal tissue injury with microbubbles targeted to P-selectin. Circulation, 2001, 104(17): 107-112.
    • (2001) Circulation , vol.104 , Issue.17 , pp. 107-112
    • Lindner, J.R.1    Song, J.2    Christiansen, J.3
  • 8
    • 33846421119 scopus 로고    scopus 로고
    • Myocardial Ischemic Memory Imaging with Molecular Echocardiography
    • Villanueva F S, Lu E, Bowry S, et al. Myocardial Ischemic Memory Imaging with Molecular Echocardiography. Circulation, 2007, 115(3): 345-352.
    • (2007) Circulation , vol.115 , Issue.3 , pp. 345-352
    • Villanueva, F.S.1    Lu, E.2    Bowry, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.