메뉴 건너뛰기




Volumn 44, Issue 12, 2009, Pages 2521-2526

Wind effects on smoke motion and temperature of ventilation-controlled fire in a two-vent compartment

Author keywords

Compartment fire; Post flashover; Smoke; Wind

Indexed keywords

COMPARTMENT FIRE; COMPARTMENT FIRES; CRITICAL VALUE; CRITICAL WIND SPEED; FIRE BEHAVIOR; HIGH RISE BUILDING; HIGH-RISE BUILDING FIRE; POST-FLASHOVER; SMOKE MOVEMENT; SMOKE TEMPERATURE; STEADY STATE; WIND ENVIRONMENT; WIND SPEED;

EID: 67651014487     PISSN: 03601323     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.buildenv.2009.04.008     Document Type: Article
Times cited : (44)

References (21)
  • 2
    • 57749181799 scopus 로고    scopus 로고
    • Modeling thermal behaviors of window flame ejected from a fire compartment
    • Himoto K., Tsuchihashi T., Tanaka Y., and Tanaka T. Modeling thermal behaviors of window flame ejected from a fire compartment. Fire Safety Journal 44 2 (2009) 230-240
    • (2009) Fire Safety Journal , vol.44 , Issue.2 , pp. 230-240
    • Himoto, K.1    Tsuchihashi, T.2    Tanaka, Y.3    Tanaka, T.4
  • 3
    • 67651013377 scopus 로고    scopus 로고
    • Code of Practice in Wind Effects in Hong Kong. The Government of Hong Kong Special Administrative Region; 2004.
    • Code of Practice in Wind Effects in Hong Kong. The Government of Hong Kong Special Administrative Region; 2004.
  • 4
    • 27744489338 scopus 로고    scopus 로고
    • The new Hong Kong wind code 2004
    • Lo S.K.L. The new Hong Kong wind code 2004. Structural Engineer 83 (2005) 22-24
    • (2005) Structural Engineer , vol.83 , pp. 22-24
    • Lo, S.K.L.1
  • 6
    • 34548601961 scopus 로고    scopus 로고
    • Wind effects on performance of smoke exhaust systems for tall buildings in Taiwan
    • Yang Y.-C., Su C.-H., Hsieh T.-L., and Chung K.-C. Wind effects on performance of smoke exhaust systems for tall buildings in Taiwan. Journal of Applied Fire Science 14 (2005) 189-203
    • (2005) Journal of Applied Fire Science , vol.14 , pp. 189-203
    • Yang, Y.-C.1    Su, C.-H.2    Hsieh, T.-L.3    Chung, K.-C.4
  • 8
    • 4444220465 scopus 로고    scopus 로고
    • Impact of floor planning on airflow patterns in designated refuge floor in high-rise building
    • Lu W., Lu W.Z., Yuen K.K., Lo S.M., and Fang Z. Impact of floor planning on airflow patterns in designated refuge floor in high-rise building. Journal of Architectural Engineering 8 (2002) 108-115
    • (2002) Journal of Architectural Engineering , vol.8 , pp. 108-115
    • Lu, W.1    Lu, W.Z.2    Yuen, K.K.3    Lo, S.M.4    Fang, Z.5
  • 10
    • 43749115204 scopus 로고    scopus 로고
    • Effects of building wall arrangements on wind-induced ventilation through the refuge floor of a tall building
    • Cheng C., Lam K., and Demirbilek F. Effects of building wall arrangements on wind-induced ventilation through the refuge floor of a tall building. Journal of Wind Engineering and Industrial Aerodynamics 96 5 (2008) 656-664
    • (2008) Journal of Wind Engineering and Industrial Aerodynamics , vol.96 , Issue.5 , pp. 656-664
    • Cheng, C.1    Lam, K.2    Demirbilek, F.3
  • 11
    • 20344377643 scopus 로고    scopus 로고
    • Wind effects on performance of static smoke exhaust systems: horizontal ceiling vents
    • Chow W.K., and Li J. Wind effects on performance of static smoke exhaust systems: horizontal ceiling vents. ASHRAE 2004 Annual Meeting (2004) 1-10
    • (2004) ASHRAE 2004 Annual Meeting , pp. 1-10
    • Chow, W.K.1    Li, J.2
  • 12
    • 0347314918 scopus 로고    scopus 로고
    • Wind effects on smoke motion in buildings
    • Porch M., and Trebukov S. Wind effects on smoke motion in buildings. Fire Safety Journal 35 3 (2000) 257-273
    • (2000) Fire Safety Journal , vol.35 , Issue.3 , pp. 257-273
    • Porch, M.1    Trebukov, S.2
  • 13
    • 33748933887 scopus 로고    scopus 로고
    • Airflow rates by combined natural ventilation with opposing wind-unambiguous solutions for practical use
    • Andersen K.T. Airflow rates by combined natural ventilation with opposing wind-unambiguous solutions for practical use. Building and Environment 42 2 (2007) 534-542
    • (2007) Building and Environment , vol.42 , Issue.2 , pp. 534-542
    • Andersen, K.T.1
  • 14
    • 34250019396 scopus 로고    scopus 로고
    • Transitions between the multiple steady states in a natural ventilation system with combined buoyancy and wind driven flows
    • Yuan J., and Glicksman L.R. Transitions between the multiple steady states in a natural ventilation system with combined buoyancy and wind driven flows. Building and Environment 42 10 (2007) 3500-3516
    • (2007) Building and Environment , vol.42 , Issue.10 , pp. 3500-3516
    • Yuan, J.1    Glicksman, L.R.2
  • 15
    • 0035238968 scopus 로고    scopus 로고
    • Natural ventilation induced by combined wind and thermal forces
    • Li Y.G., and Delsante A. Natural ventilation induced by combined wind and thermal forces. Building and Environment 36 1 (2001) 59-71
    • (2001) Building and Environment , vol.36 , Issue.1 , pp. 59-71
    • Li, Y.G.1    Delsante, A.2
  • 16
    • 0033489551 scopus 로고    scopus 로고
    • The fluid mechanics of natural ventilation
    • Linden P.F. The fluid mechanics of natural ventilation. Annual Review of Fluid Mechanics 31 (1999) 201-238
    • (1999) Annual Review of Fluid Mechanics , vol.31 , pp. 201-238
    • Linden, P.F.1
  • 21
    • 34548381640 scopus 로고    scopus 로고
    • Multiple steady states in combined buoyancy and wind driven natural ventilation: The conditions for multiple solutions and the critical point for initial conditions
    • Yuan J.C., and Glicksman L.R. Multiple steady states in combined buoyancy and wind driven natural ventilation: The conditions for multiple solutions and the critical point for initial conditions. Building and Environment 43 1 (2008) 62-69
    • (2008) Building and Environment , vol.43 , Issue.1 , pp. 62-69
    • Yuan, J.C.1    Glicksman, L.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.