메뉴 건너뛰기




Volumn 17, Issue 3, 2009, Pages 285-297

The voltammetric determination of phenolphthalein on multi-walled carbon nanotube-DHP composite film-modified glassy carbon electrode

Author keywords

Electrocatalysis; Linear sweep voltammetry; Modified electrode; Multi walled carbon nanotube; Phenolphthalein

Indexed keywords

A-CARBON; DIHEXADECYL PHOSPHATE; ELECTROCATALYTIC BEHAVIOR; ELECTROCATALYTIC EFFECTS; ELECTROCHEMICAL METHODS; EXPERIMENTAL PARAMETERS; FILM ELECTRODES; GLASSY CARBON ELECTRODES; HOMOGENEOUS SUSPENSIONS; IN-SITU; LINEAR RESPONSE; LINEAR SWEEP VOLTAMMETRY; MODIFIED ELECTRODE; MODIFIED GLASSY CARBON ELECTRODE; OPTIMAL CONDITIONS; OXIDATION CURRENTS; PHENOLPHTHALEIN; REAL SAMPLES; SENSITIVE MEASUREMENT; SMALL REDUCTION; SOLVENT EVAPORATION; UNIFORM FILMS; VOLTAMMETRIC; VOLTAMMETRIC DETERMINATION;

EID: 67650909130     PISSN: 1536383X     EISSN: 15364046     Source Type: Journal    
DOI: 10.1080/15363830902779619     Document Type: Article
Times cited : (7)

References (20)
  • 1
    • 0030718512 scopus 로고    scopus 로고
    • Persistence of selected pesticides and their phenolic transformation products in natural water using off-line liquid solid extraction followed by liquid chromatographic techniques
    • Castillo, M., Domingues, R., Alpendurada, M.F., and Barcel'o, D. (1997) Persistence of selected pesticides and their phenolic transformation products in natural water using off-line liquid solid extraction followed by liquid chromatographic techniques. Anal. Chim. Acta, 353: 133.
    • (1997) Anal. Chim. Acta , vol.353 , pp. 133
    • Castillo, M.1    Domingues, R.2    Alpendurada, M.F.3    Barcel'O, D.4
  • 2
    • 0035955814 scopus 로고    scopus 로고
    • Analysis of phenols in pharmaceuticals by liquid chromatography after pre-column labelling and on-line post-column photochemical derivatization
    • 10.1016/S0003-2670(01)01292-2, PII S0003267001012922
    • 2. Gatti, R., Gioia, M.G., Di Pietra, A.M., and Cavrini, V. (2001) Analysis of phenols in pharmaceuticals by liquid chromatography after precolumn labeling and on-line post-column photochemical derivatization. Anal. Chim. Acta, 447: 89. (Pubitemid 33044600)
    • (2001) Analytica Chimica Acta , vol.447 , Issue.1-2 , pp. 89-99
    • Gatti, R.1    Gioia, M.G.2    Di Pietra, A.M.3    Cavrini, V.4
  • 3
    • 0016532639 scopus 로고
    • Chromatographic determination of phenols in water
    • Chriswell, CD., Chang, R.C., and Fritz, J.S. (1975) Chromatographic determination of phenols in water. Anal. Chem., 47: 1325.
    • (1975) Anal. Chem. , vol.47 , pp. 1325
    • Chriswell, C.D.1    Chang, R.C.2    Fritz, J.S.3
  • 4
    • 7444226886 scopus 로고    scopus 로고
    • Extraction and analysis of phenolics in food
    • 10.1016/j.chroma.2004.08.059, PII S0021967304014098, Food Science
    • 4. Naczk, M. and Shahidi, F. (2004) Extraction and analysis of phenolics in food. J. Chromatogr. A, 1054: 95. (Pubitemid 39445814)
    • (2004) Journal of Chromatography A , vol.1054 , Issue.1-2 , pp. 95-111
    • Naczk, M.1    Shahidi, F.2
  • 5
    • 0038362475 scopus 로고    scopus 로고
    • Simultaneous determination of dopamine serotonin on a glassy carbon electrode coated with a film of carbon nanotubes
    • Wu, K.B., Fei, J.J., and Hu, S.S. (2003) Simultaneous determination of dopamine serotonin on a glassy carbon electrode coated with a film of carbon nanotubes. Anal. Biochem., 318: 100.
    • (2003) Anal. Biochem. , vol.318 , pp. 100
    • Wu, K.B.1    Fei, J.J.2    Hu, S.S.3
  • 6
    • 33947722557 scopus 로고    scopus 로고
    • Study on the electrochemical behavior and differential pulse voltammetric determination of rhein using a nanoparticle composite film-modified electrode
    • 10.1016/j.bioelechem.2006.05.007, PII S156753940600082X
    • 6. Fei, J.J., Tan, H.Y., Chen, X.M., Yang, J., and Li, J.N. (2007) Study on the electrochemical behavior and differential pulse voltammetric determination of rhein using a nanoparticle composite film-modified electrode. Bioelectrochem., 70: 369. (Pubitemid 46507954)
    • (2007) Bioelectrochemistry , vol.70 , Issue.2 , pp. 369-374
    • Fei, J.1    Peng, Y.2    Tan, H.3    Chen, X.4    Yang, J.5    Li, J.6
  • 7
    • 34547621063 scopus 로고    scopus 로고
    • Direct electron transfer of hemoglobin on dihexadecyl hydrogen phosphate/single-wall carbon nanotubes film modified Au electrode and its interaction with taxol
    • 10.1134/S102319350707004X
    • 7. Zhang, Y.Z., Cheng, W.X., and Li, S.P. (2007) Direct electron transfer of hemoglobin on dihexadecyl hydrogen phosphate/single-walled carbon nanotubes film modified Au electrode and its interaction with taxol. Ru. J. Electrochem., 43: 764. (Pubitemid 47206641)
    • (2007) Russian Journal of Electrochemistry , vol.43 , Issue.7 , pp. 764-769
    • Zhang, Y.Z.1    Cheng, W.X.2    Li, S.P.3
  • 8
    • 27344458557 scopus 로고    scopus 로고
    • Low potential amperometric determination of ascorbic acid at a single-walled carbon nanotubes dihexadecyl hydrogen phosphate composite film modified electrode
    • Fei, J.J., Wu, K.B., Yi, L.H., and Li, J.N. (2005) Low potential amperometric determination of ascorbic acid at a single-walled carbon nanotubes dihexadecyl hydrogen phosphate composite film modified electrode. Bull. Korean Chem. Soc., 26: 1403.
    • (2005) Bull. Korean Chem. Soc. , vol.26 , pp. 1403
    • Fei, J.J.1    Wu, K.B.2    Yi, L.H.3    Li, J.N.4
  • 9
    • 33746908582 scopus 로고    scopus 로고
    • Studies on electrochemical behaviors of acyclovir and its voltammetric determination with nano-structured film electrode
    • 10.1016/j.aca.2005.12.023, PII S000326700502057X
    • 9. Wang, F., Chen, L., Chen, X.X., and Hu, S.S. (2006) Studies on electrochemical behaviors of acyclovir and its voltammetric determination with nanostructured film electrode. Anal. Chim. Acta, 576: 17. (Pubitemid 44189282)
    • (2006) Analytica Chimica Acta , vol.576 , Issue.1 , pp. 17-22
    • Wang, F.1    Chen, L.2    Chen, X.3    Hu, S.4
  • 10
    • 34447519157 scopus 로고    scopus 로고
    • Enhanced oxidation of estrone at multi-walled carbon nanotubes film electrode: Direct evidence for the advantage of carbon nanotubes over other carbonaceous materials
    • Yu, J.J., Zhao, J., Hu, C.G., and Hu, S.S. (2007) Enhanced oxidation of estrone at multi-walled carbon nanotubes film electrode: Direct evidence for the advantage of carbon nanotubes over other carbonaceous materials. J. Nanosci. Nanotech., 7: 1631.
    • (2007) J. Nanosci. Nanotech. , vol.7 , pp. 1631
    • Yu, J.J.1    Zhao, J.2    Hu, C.G.3    Hu, S.S.4
  • 11
    • 34247337977 scopus 로고    scopus 로고
    • Development of an acetylspiramycin sensor based on a single-walled carbon nanotubes film electrode
    • Peng, Y., Lu, Q., Hu, B.L., Wang, Z.B., and Hu, S.S. (2007) Development of an acetylspiramycin sensor based on a single-walled carbon nanotubes film electrode. Microchim. Acta, 158: 79.
    • (2007) Microchim. Acta , vol.158 , pp. 79
    • Peng, Y.1    Lu, Q.2    Hu, B.L.3    Wang, Z.B.4    Hu, S.S.5
  • 12
    • 4444319913 scopus 로고    scopus 로고
    • Mercury-free simultaneous determination of cadmium and lead at a glassy carbon electrode modified with multi-walled carbon nanotubes
    • Wu, K.B., Hu, S.S., Fei, J.J, and Bai, W. (2003) Mercury-free simultaneous determination of cadmium and lead at a glassy carbon electrode modified with multi-walled carbon nanotubes. Anal. Chim. Acta, 489: 215.
    • (2003) Anal. Chim. Acta , vol.489 , pp. 215
    • Wu, K.B.1    Hu, S.S.2    Fei, J.J.3    Bai, W.4
  • 13
    • 67650954722 scopus 로고
    • Quantification of phenolphthalein in cosmetic products
    • Zoltainematolcsy, E. and Szaboneakos, Z. (1981) Quantification of Phenolphthalein in cosmetic products. Acta Pharm. Hung., 51: 204.
    • (1981) Acta Pharm. Hung. , vol.51 , pp. 204
    • Zoltainematolcsy, E.1    Szaboneakos, Z.2
  • 14
    • 84921180626 scopus 로고
    • H. M. Stationery Office: London
    • British Pharmacopoeia, Vol.2 (1993); H. M. Stationery Office: London, p. 430.
    • (1993) British Pharmacopoeia , vol.2 , pp. 430
  • 15
    • 44949266500 scopus 로고
    • Determination of Phenolphthalein by reverse phase high-performance liquid chromatography
    • Geeta, N. and Baggi, T.R. (1990) Determination of Phenolphthalein by reverse phase high-performance liquid chromatography. Microchem. J., 42: 170.
    • (1990) Microchem. J. , vol.42 , pp. 170
    • Geeta, N.1    Baggi, T.R.2
  • 16
    • 0029112061 scopus 로고
    • Comparison of reversed-phase liquid chromatography with colorimetry for analysis of Phenolphthalein preparations
    • Torrado, S., Fraile, S., Torrado, J.J.V., and Selles, E. (1995) Comparison of reversed-phase liquid chromatography with colorimetry for analysis of Phenolphthalein preparations. J. Pharm. Biomed. Anal., 13: 1167.
    • (1995) J. Pharm. Biomed. Anal. , vol.13 , pp. 1167
    • Torrado, S.1    Fraile, S.2    Torrado, J.J.V.3    Selles, E.4
  • 17
    • 33845713133 scopus 로고    scopus 로고
    • Highly stable electrochemical oxidation of phenolic compounds at carbon ionic liquid electrode
    • 10.1039/b612672c
    • 17. Safavi, A., Maleki, N., and Tajabadi, F. (2007) Highly stable electrochemical oxidation of phenolic compounds at carbon ionic liquid electrode. Analyst, 132: 54. (Pubitemid 44968851)
    • (2007) Analyst , vol.132 , Issue.1 , pp. 54-58
    • Safavi, A.1    Maleki, N.2    Tajabadi, F.3
  • 18
    • 27744541817 scopus 로고
    • Obtaining thin films of "reactive polymers" on metal surfaces by electrochemical polymerization part I. Reactivity of functional groups in a carbonyl substituted polyphenylene oxide film
    • Pham, M., Lacaze, P., and Dubois J. (1978) Obtaining thin films of "reactive polymers" on metal surfaces by electrochemical polymerization part I. Reactivity of functional groups in a carbonyl substituted polyphenylene oxide film. J. Electroanal. Chem., 86: 147.
    • (1978) J. Electroanal. Chem. , vol.86 , pp. 147
    • Pham, M.1    Lacaze, P.2    Dubois, J.3
  • 19
    • 0000663080 scopus 로고
    • Scanning tunneling microscopic investigation of surface fouling of glassy carbon surfaces due to phenol oxidation
    • Wang, J., Martinez, T., Yaniv, D.R., and McCormick, L.D. (1991) Scanning tunneling microscopic investigation of surface fouling of glassy carbon surfaces due to phenol oxidation. J. Electroanal. Chem., 313: 129.
    • (1991) J. Electroanal. Chem. , vol.313 , pp. 129
    • Wang, J.1    Martinez, T.2    Yaniv, D.R.3    McCormick, L.D.4
  • 20
    • 0032485165 scopus 로고    scopus 로고
    • Electrochemical quartz crystal microbalance investigation of surface fouling due to phenol oxidation
    • PII S0022072897005834
    • 20. Wang, J., Jiang, M., and Lu, F. (1998) Electrochemical quartz crystal microbalance investigation of surface fouling due to phenol oxidation. J. Electroanal. Chem., 444: 127. (Pubitemid 128413952)
    • (1998) Journal of Electroanalytical Chemistry , vol.444 , Issue.1 , pp. 127-132
    • Wang, J.1    Jiang, M.2    Lu, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.