메뉴 건너뛰기




Volumn 10, Issue 5, 2009, Pages 619-624

Assessment of right ventricular function by real-time three-dimensional echocardiography improves accuracy and decreases interobserver variability compared with conventional two-dimensional views

Author keywords

Right ventricle function; Three dimensional echocardiography

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; FUNCTIONAL ASSESSMENT; HEART RIGHT VENTRICLE EJECTION FRACTION; HEART RIGHT VENTRICLE FUNCTION; HUMAN; INTERMETHOD COMPARISON; MATHEMATICAL COMPUTING; OBSERVER VARIATION; PRIORITY JOURNAL; REAL TIME ECHOGRAPHY; STANDARDIZATION; THREE DIMENSIONAL ECHOCARDIOGRAPHY;

EID: 67650908410     PISSN: 15252167     EISSN: 15322114     Source Type: Journal    
DOI: 10.1093/ejechocard/jep013     Document Type: Article
Times cited : (31)

References (27)
  • 1
    • 3242707807 scopus 로고    scopus 로고
    • Impact of pregnancy on the systemic right ventricle after a Mustard operation for transposition of the great arteries
    • Guedes A, Mercier LA, Leduc L, Berube L, Marcotte F, Dore A. Impact of pregnancy on the systemic right ventricle after a Mustard operation for transposition of the great arteries. J Am Coll Cardiol 2004;44:433-7.
    • (2004) J Am Coll Cardiol , vol.44 , pp. 433-437
    • Guedes, A.1    Mercier, L.A.2    Leduc, L.3    Berube, L.4    Marcotte, F.5    Dore, A.6
  • 2
    • 16544395077 scopus 로고    scopus 로고
    • Right ventricular function after pulmonary valve replacement in patients with tetralogy of Fallot
    • Van Straten A, Vliegen HW, Hazekamp MG, Bax JJ, Schoof PH, Ottenkamp J et al. Right ventricular function after pulmonary valve replacement in patients with tetralogy of Fallot. Radiology 2004;233: 824-9.
    • (2004) Radiology , vol.233 , pp. 824-829
    • Van Straten, A.1    Vliegen, H.W.2    Hazekamp, M.G.3    Bax, J.J.4    Schoof, P.H.5    Ottenkamp, J.6
  • 3
    • 8744253594 scopus 로고    scopus 로고
    • Assessment of systemic right ventricular function in patients with transposition of the great arteries using the myocardial performance index: Comparison with cardiac magnetic resonance imaging
    • Salehian O, Schwerzmann M, Merchant N, Webb GD, Siu SC, Therrien J. Assessment of systemic right ventricular function in patients with transposition of the great arteries using the myocardial performance index: comparison with cardiac magnetic resonance imaging. Circulation 2004;110:3229-33.
    • (2004) Circulation , vol.110 , pp. 3229-3233
    • Salehian, O.1    Schwerzmann, M.2    Merchant, N.3    Webb, G.D.4    Siu, S.C.5    Therrien, J.6
  • 4
    • 7444226207 scopus 로고    scopus 로고
    • Long-term outcome after senning operation for transposition of the great arteries
    • Agnetti A, Carano N, Cavalli C, Tchana B, Bini M, Squarcia U et al. Long-term outcome after senning operation for transposition of the great arteries. Clin Cardiol 2004;27:611-4.
    • (2004) Clin Cardiol , vol.27 , pp. 611-614
    • Agnetti, A.1    Carano, N.2    Cavalli, C.3    Tchana, B.4    Bini, M.5    Squarcia, U.6
  • 5
    • 18744395217 scopus 로고    scopus 로고
    • Correlation between right ventricular indices and clinical improvement in epoproste- nol treated pulmonary hypertension patients
    • Nath J, Demarco T, Hourigan L, Heidenreich PA, Foster E. Correlation between right ventricular indices and clinical improvement in epoproste- nol treated pulmonary hypertension patients. Echocardiography 2005; 22:374-9.
    • (2005) Echocardiography , vol.22 , pp. 374-379
    • Nath, J.1    Demarco, T.2    Hourigan, L.3    Heidenreich, P.A.4    Foster, E.5
  • 7
    • 0026751295 scopus 로고
    • Three-dimensional echocardiography: Techniques and applications
    • Levine RA, Weyman AE, Handschumacher MD. Three-dimensional echocardiography: techniques and applications. Am J Cardiol 1992;69:121-34.
    • (1992) Am J Cardiol , vol.69 , pp. 121-134
    • Levine, R.A.1    Weyman, A.E.2    Handschumacher, M.D.3
  • 9
    • 0030827844 scopus 로고    scopus 로고
    • Comparison of transthoracic three-dimensional echocardiography with magnetic resonance imaging in the assessment of right ventricular volume and mass
    • Vogel M, Gutberlet M, Dittrich S, Hosten N, Lange PE. Comparison of transthoracic three-dimensional echocardiography with magnetic resonance imaging in the assessment of right ventricular volume and mass. Heart 1997;78:127-30.
    • (1997) Heart , vol.78 , pp. 127-130
    • Vogel, M.1    Gutberlet, M.2    Dittrich, S.3    Hosten, N.4    Lange, P.E.5
  • 10
    • 0029130447 scopus 로고
    • In vitro validation of right ventricular volume measurement by three-dimensional echocardiography
    • Vogel M, White PA, Redington AN. In vitro validation of right ventricular volume measurement by three-dimensional echocardiography. Br Heart J 1995;74:460-3.
    • (1995) Br Heart J , vol.74 , pp. 460-463
    • Vogel, M.1    White, P.A.2    Redington, A.N.3
  • 12
    • 0028399727 scopus 로고
    • Three-dimensional echocardiographic reconstruction of right ventricular volume: In vitro comparison with two-dimensional methods
    • Jiang L, Handschumacher MD, Hibberd MG, Siu SC, King ME, Weyman AE et al. Three-dimensional echocardiographic reconstruction of right ventricular volume: in vitro comparison with two-dimensional methods. J Am Soc Echocardiogr 1994;7:150-8.
    • (1994) J Am Soc Echocardiogr , vol.7 , pp. 150-158
    • Jiang, L.1    Handschumacher, M.D.2    Hibberd, M.G.3    Siu, S.C.4    King, M.E.5    Weyman, A.E.6
  • 13
    • 0031025850 scopus 로고    scopus 로고
    • Trans- thoracic three-dimensional echocardiographic reconstruction of left and right ventricles: In vitro validation and comparison with magnetic resonance imaging
    • Pini R, Giannazzo G, Di Bari M, Innocenti F, Rega L, Casolo G et al. Trans- thoracic three-dimensional echocardiographic reconstruction of left and right ventricles: in vitro validation and comparison with magnetic resonance imaging. Am Heart J 1997;33:221-9.
    • (1997) Am Heart J , vol.33 , pp. 221-229
    • Pini, R.1    Giannazzo, G.2    Di Bari, M.3    Innocenti, F.4    Rega, L.5    Casolo, G.6
  • 14
    • 33747892717 scopus 로고    scopus 로고
    • Quantitation of right ventricular volumes and ejection fraction by three- dimensional echocardiography in patients: Comparison with magnetic resonance imaging and radionuclide ventriculography
    • Nesser HJ, Tkalec W, Patel AR, Masani ND, Niel J, Markt B et al. Quantitation of right ventricular volumes and ejection fraction by three- dimensional echocardiography in patients: comparison with magnetic resonance imaging and radionuclide ventriculography. Echocardiography 2006;23:666-80.
    • (2006) Echocardiography , vol.23 , pp. 666-680
    • Nesser, H.J.1    Tkalec, W.2    Patel, A.R.3    Masani, N.D.4    Niel, J.5    Markt, B.6
  • 15
    • 33847306718 scopus 로고    scopus 로고
    • Optimal assessment of right ventricular size and function by real-time 3D echocardiography: Comparison to cardiac magnetic resonance imaging
    • No. 2654, 110Suppl. III-570
    • Nabeel H. Optimal assessment of right ventricular size and function by real-time 3D echocardiography: comparison to cardiac magnetic resonance imaging. Circulation (No. 2654) 2004;110(Suppl. III-570).
    • (2004) Circulation
    • Nabeel, H.1
  • 16
    • 1842778839 scopus 로고    scopus 로고
    • Determination of asymmetric cavity volumes using real-time three-dimensional echocardiography: An in vitro Balloon Model Study
    • Prakash K, Li X, Hejmadi A, Hashimoto I, Sahn DJ. Determination of asymmetric cavity volumes using real-time three-dimensional echocardiography: an in vitro Balloon Model Study. Echocardiography 2004;21:257-63.
    • (2004) Echocardiography , vol.21 , pp. 257-263
    • Prakash, K.1    Li, X.2    Hejmadi, A.3    Hashimoto, I.4    Sahn, D.J.5
  • 17
    • 34247629514 scopus 로고    scopus 로고
    • Normal values of right ventricular size and function by real-time 3- dimensional echocardiography: Comparison with cardiac magnetic resonance imaging
    • Gopal AS, Chukwu EO, Iwuchukwu CJ, Katz AS, Toole RS, Schapiro W et al. Normal values of right ventricular size and function by real-time 3- dimensional echocardiography: comparison with cardiac magnetic resonance imaging. J Am Soc Echocardiogr 2007;20:445-55.
    • (2007) J Am Soc Echocardiogr , vol.20 , pp. 445-455
    • Gopal, A.S.1    Chukwu, E.O.2    Iwuchukwu, C.J.3    Katz, A.S.4    Toole, R.S.5    Schapiro, W.6
  • 18
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 19
    • 2342585477 scopus 로고    scopus 로고
    • Right ventricular volumes are rarely right and are right hard to do
    • Bashore TM. Right ventricular volumes are rarely right and are right hard to do. Catheter Cardiovasc Interv 2004;62:52-5.
    • (2004) Catheter Cardiovasc Interv , vol.62 , pp. 52-55
    • Bashore, T.M.1
  • 20
    • 2342635221 scopus 로고    scopus 로고
    • Measurement of right ventricular volume from biplane contrast ventriculograms: Validation by cast and three- dimensional echo
    • Sheehan FH, Bolson EL. Measurement of right ventricular volume from biplane contrast ventriculograms: validation by cast and three- dimensional echo. Catheter Cardiovasc Interv 2004;62:46-51.
    • (2004) Catheter Cardiovasc Interv , vol.62 , pp. 46-51
    • Sheehan, F.H.1    Bolson, E.L.2
  • 22
    • 0842304408 scopus 로고    scopus 로고
    • Inter- study reproducibility of right ventricular volumes, function, and mass with cardiovascular magnetic resonance
    • Grothues F, Moon JC, Bellenger NG, Smith GS, Klein HU, Pennell DJ. Inter- study reproducibility of right ventricular volumes, function, and mass with cardiovascular magnetic resonance. Am Heart J 2004;147:218-23.
    • (2004) Am Heart J , vol.147 , pp. 218-223
    • Grothues, F.1    Moon, J.C.2    Bellenger, N.G.3    Smith, G.S.4    Klein, H.U.5    Pennell, D.J.6
  • 23
    • 12544258711 scopus 로고    scopus 로고
    • Assessment of right ventricular function by 16-detector-row CT: Comparison with magnetic resonance imaging
    • Koch K, Oellig F, Oberholzer K, Bender P, Kunz P, Mildenberger P et al. Assessment of right ventricular function by 16-detector-row CT: comparison with magnetic resonance imaging. Eur Radiol 2005;15:312-8.
    • (2005) Eur Radiol , vol.15 , pp. 312-318
    • Koch, K.1    Oellig, F.2    Oberholzer, K.3    Bender, P.4    Kunz, P.5    Mildenberger, P.6
  • 24
    • 0032321648 scopus 로고    scopus 로고
    • Estimation of the right ventricular volume and ejection fraction by transthoracic three- dimensional echocardiography. A validation study using magnetic resonance imaging
    • Fujimoto S, Mizuno R, Nakagawa Y, Dohi K, Nakano H. Estimation of the right ventricular volume and ejection fraction by transthoracic three- dimensional echocardiography. A validation study using magnetic resonance imaging. Int J Card Imaging 1998;14:385-90.
    • (1998) Int J Card Imaging , vol.14 , pp. 385-390
    • Fujimoto, S.1    Mizuno, R.2    Nakagawa, Y.3    Dohi, K.4    Nakano, H.5
  • 25
    • 0024624821 scopus 로고
    • Determination of right ventricular volume by two-dimensional echocardiography with a crescentic model
    • Aebischer NM, Czegledy F. Determination of right ventricular volume by two-dimensional echocardiography with a crescentic model. J Am Soc Echocardiogr 1989;2:110-8.
    • (1989) J Am Soc Echocardiogr , vol.2 , pp. 110-118
    • Aebischer, N.M.1    Czegledy, F.2
  • 26
    • 0021321797 scopus 로고
    • Assessment of right ventricular function using two-dimensional echocardiography
    • Kaul S, Tei C, Hopkins JM, Shah PM. Assessment of right ventricular function using two-dimensional echocardiography. Am Heart J 1984; 107:526-31.
    • (1984) Am Heart J , vol.107 , pp. 526-531
    • Kaul, S.1    Tei, C.2    Hopkins, J.M.3    Shah, P.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.