메뉴 건너뛰기




Volumn 90 B, Issue 1, 2009, Pages 223-228

Acoustic emission monitoring and 3D visualization of polymerization-induced damage of acrylic polymer materials

Author keywords

Acrylic; Bone cement; Joint replacement; PMMA; Polymerization

Indexed keywords

ACOUSTIC EMISSION TESTING; ACOUSTIC EMISSIONS; ACOUSTICS; BONE; CEMENTS; COMPUTERIZED TOMOGRAPHY; CONCRETE MIXING; HIP PROSTHESES; INSPECTION; MEDICAL IMAGING; POLYMERIZATION; POLYMERS; SHRINKAGE; THREE DIMENSIONAL COMPUTER GRAPHICS; TOMOGRAPHY;

EID: 67650831903     PISSN: 15524973     EISSN: 15524981     Source Type: Journal    
DOI: 10.1002/jbm.b.31276     Document Type: Article
Times cited : (6)

References (23)
  • 1
    • 0034980107 scopus 로고    scopus 로고
    • Influence of mixing techniques on the physical properties of acrylic bone cement
    • DOI 10.1016/S0142-9612(00)00363-X, PII S014296120000363X
    • Dunne N, Orr J. Influence of mixing techniques on the physical properties of acrylic bone cement. Biomaterials 2001;22: 1819-1826. (Pubitemid 32564971)
    • (2001) Biomaterials , vol.22 , Issue.13 , pp. 1819-1826
    • Dunne, N.J.1    Orr, J.F.2
  • 2
    • 0027535641 scopus 로고    scopus 로고
    • Extensive porosity at the cement-femoral prosthesis interface: A preliminary study
    • James S, Schmalzried T, McGarry F, Harris W. Extensive porosity at the cement-femoral prosthesis interface: A preliminary study. J Biomed Mater Res 2004;27:71-78.
    • (2004) J Biomed Mater Res , vol.27 , pp. 71-78
    • James, S.1    Schmalzried, T.2    McGarry, F.3    Harris, W.4
  • 4
    • 34848908017 scopus 로고    scopus 로고
    • Vacuum-mixing cement does not decrease overall porosity in cemented femoral stems: An in vitro laboratory investigation
    • DOI 10.1302/0301-620X.89B8.19129
    • Messick K, Miller M, Damron L, Race A, Clarke MT, Mann KA. Vacuum-mixing cement does not decrease overall porosity in cemented femoral stems an in vitro laboratory investigation. J Bone Joint Surg Br 2007;89:1115-1121. (Pubitemid 47492811)
    • (2007) Journal of Bone and Joint Surgery - Series B , vol.89 , Issue.8 , pp. 1115-1121
    • Messick, K.J.1    Miller, M.A.2    Damron, L.A.3    Race, A.4    Clarke, M.T.5    Mann, K.A.6
  • 5
    • 0036909341 scopus 로고    scopus 로고
    • The dynamic volume changes of polymerising polymethyl methacrylate bone cement
    • DOI 10.1080/000164702321039688
    • Muller S, Green S, McCaskie A. The dynamic volume changes of polymerising polymethyl methacrylate bone cement. Acta Orthop Scand 2002;73:684-687. (Pubitemid 36020915)
    • (2002) Acta Orthopaedica Scandinavica , vol.73 , Issue.6 , pp. 684-687
    • Muller, S.D.1    Green, S.M.2    McCaskie, A.W.3
  • 6
    • 31144451199 scopus 로고    scopus 로고
    • A comparison of the shrinkage of commercial bone cements when mixed under vacuum
    • DOI 10.1302/0301-620X.88B1.16600
    • Kwong F, Power R. A comparison of the shrinkage of commercial bone cements when mixed under vacuum. J Bone Joint Surg Br 2006;88:120-122. (Pubitemid 43125327)
    • (2006) Journal of Bone and Joint Surgery - Series B , vol.88 , Issue.1 , pp. 120-122
    • Kwong, F.N.K.1    Power, R.A.2
  • 8
    • 0036171714 scopus 로고    scopus 로고
    • Residual stress due to curing can initiate damage in porous bone cement: Experimental and theoretical evidence
    • DOI 10.1016/S0021-9290(01)00216-0, PII S0021929001002160
    • Lennon A, Prendergast P. Residual stress due to curing can initiate damage in porous bone cement: Experimental and theoretical evidence. J Biomech 2002;35:311-321. (Pubitemid 34150175)
    • (2002) Journal of Biomechanics , vol.35 , Issue.3 , pp. 311-321
    • Lennon, A.B.1    Prendergast, P.J.2
  • 9
    • 0034255618 scopus 로고    scopus 로고
    • A theoretical and experimental analysis of polymerization shrinkage of bone cement: A potential major source of porosity
    • DOI 10.1002/1097-4636(200010)52:1<210::AID-JBM27>3.0.CO;2-R
    • Gilbert J, Hasenwinkel J, Wixson R, Lautenschlager E. A theoretical and experimental analysis of polymerization shrinkage of bone cement: A potential major source of porosity. J Biomed Mater Res 2000;52:210-218. (Pubitemid 30490999)
    • (2000) Journal of Biomedical Materials Research , vol.52 , Issue.1 , pp. 210-218
    • Gilbert, J.L.1    Hasenwinkel, J.M.2    Wixson, R.L.3    Lautenschlager, E.P.4
  • 10
    • 0038078475 scopus 로고    scopus 로고
    • Shrinkage stresses in bone cement
    • Orr J, Dunne N, Quinn J. Shrinkage stresses in bone cement. Biomaterials 2003;24:2933-2940.
    • (2003) Biomaterials , vol.24 , pp. 2933-2940
    • Orr, J.1    Dunne, N.2    Quinn, J.3
  • 11
    • 0037397195 scopus 로고    scopus 로고
    • Early cement damage around a femoral stem is concentrated at the cement/bone interface
    • DOI 10.1016/S0021-9290(02)00460-8
    • Race A, Miller M, Ayers D, Mann K. Early cement damage around a femoral stem is concentrated at the cement/bone interface. J Biomech 2003;36:489-496. (Pubitemid 36207579)
    • (2003) Journal of Biomechanics , vol.36 , Issue.4 , pp. 489-496
    • Race, A.1    Miller, M.A.2    Ayers, D.C.3    Mann, K.A.4
  • 12
    • 1642402000 scopus 로고    scopus 로고
    • Quantitative measurement of the stresses induced during polymerisation of bone cement
    • DOI 10.1016/j.biomaterials.2003.11.009, PII S0142961203010755
    • Roques A, Browne M, Taylor A, New A, Baker D. Quantitative measurement of the stresses induced during polymerisation of bone cement. Biomaterials 2004;25:4415-4424. (Pubitemid 38388601)
    • (2004) Biomaterials , vol.25 , Issue.18 , pp. 4415-4424
    • Roques, A.1    Browne, M.2    Taylor, A.3    New, A.4    Baker, D.5
  • 13
    • 0036378761 scopus 로고    scopus 로고
    • Mechanical testing of the wire clamping characteristics of the FixclipTM internal fixation system
    • Vadivelu R, Baker A, Chetwynd D. Mechanical testing of the wire clamping characteristics of the FixclipTM internal fixation system. J Eng Med 2002;216:347-351.
    • (2002) J Eng Med , vol.216 , pp. 347-351
    • Vadivelu, R.1    Baker, A.2    Chetwynd, D.3
  • 14
    • 85069132901 scopus 로고    scopus 로고
    • http://www.ndt.net/article/az/ae/hsunielsensource.htm.
  • 16
    • 85069142838 scopus 로고    scopus 로고
    • www.kulzer-technik.de.
  • 17
    • 85069134425 scopus 로고    scopus 로고
    • Comparison of bone cement shrinkage between different polymethylmethacrylate commercial preparations in use
    • Kwong F, Power R. Comparison of bone cement shrinkage between different polymethylmethacrylate commercial preparations in use. J Bone Joint Surg Br 2006;88(SUPP-II): 237.
    • (2006) J Bone Joint Surg Br , vol.88 , Issue.SUPPL.-II , pp. 237
    • Kwong, F.1    Power, R.2
  • 18
    • 0029311020 scopus 로고    scopus 로고
    • Does vacuum mixing of bone cement affect heat generation? Analysis of four cement brands
    • Wang J, Franzén H, Toksvig-Larsen S, Lidgren L. Does vacuum mixing of bone cement affect heat generation? Analysis of four cement brands. J Appl Biomater 2004;6:105-108.
    • (2004) J Appl Biomater , vol.6 , pp. 105-108
    • Wang, J.1    Franzén, H.2    Toksvig-Larsen, S.3    Lidgren, L.4
  • 19
    • 0026691685 scopus 로고
    • Thermal modelling of polymerizing polymethylmethacrylate, considering temperature dependent heat generation
    • Baliga B, Rose P, Ahmed A. Thermal modelling of polymerizing polymethylmethacrylate, considering temperature dependent heat generation. J Biomech Eng 1992;114:251-259.
    • (1992) J Biomech Eng , vol.114 , pp. 251-259
    • Baliga, B.1    Rose, P.2    Ahmed, A.3
  • 21
    • 0242522398 scopus 로고    scopus 로고
    • Investigation of fatigue crack growth in acrylic bone cement using the acoustic emission technique
    • DOI 10.1016/S0142-9612(03)00581-7
    • Roques A, Browne M, Thompson J, Rowland C, Taylor A. Investigation of fatigue crack growth in acrylic bone cement using the acoustic emission technique. Biomaterials 2004;25: 769-778. (Pubitemid 37371986)
    • (2004) Biomaterials , vol.25 , Issue.5 , pp. 769-778
    • Roques, A.1    Browne, M.2    Thompson, J.3    Rowland, C.4    Taylor, A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.