메뉴 건너뛰기




Volumn 34, Issue 14, 2009, Pages 5846-5854

Safety studies of a hydrogen refuelling station: Determination of the occurrence frequency of the accidental scenarios

Author keywords

Fault tree analyses; FMEA; HAZOP; Hydrogen refuelling station; Risk analysis

Indexed keywords

DATA COLLECTION; FMEA; HAZOP; HIGH-PRESSURE STORAGE; HYDROGEN GAS; HYDROGEN VEHICLES; SAFETY ANALYSIS; SAFETY PRACTICES; SAFETY STUDIES;

EID: 67650751612     PISSN: 03603199     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijhydene.2009.01.096     Document Type: Article
Times cited : (68)

References (10)
  • 3
    • 67650716747 scopus 로고    scopus 로고
    • SEMATECH Technology Transfer 92020963B-ENG. Failure mode and effects analysis (FMEA): a guide for continuous improvement for the semiconductor equipment industry.
    • SEMATECH Technology Transfer 92020963B-ENG. Failure mode and effects analysis (FMEA): a guide for continuous improvement for the semiconductor equipment industry.
  • 5
    • 24944446591 scopus 로고    scopus 로고
    • Protection from potential exposures: application to selected radiation sources
    • Protection from potential exposures: application to selected radiation sources. Annals of the ICRP 27 2 (1997)
    • (1997) Annals of the ICRP , vol.27 , Issue.2
  • 10
    • 67650711144 scopus 로고    scopus 로고
    • Risk acceptance criteria for hydrogen refuelling stations, By Norsk Hydro ASA and DNV for WP 5.2 European integrated hydrogen project, EIHP2; February 2003.
    • Risk acceptance criteria for hydrogen refuelling stations, By Norsk Hydro ASA and DNV for WP 5.2 European integrated hydrogen project, EIHP2; February 2003.