메뉴 건너뛰기




Volumn 54, Issue 10, 2009, Pages 3141-3159

Computed tomography dose assessment for a 160 mm wide, 320 detector row, cone beam CT scanner

Author keywords

[No Author keywords available]

Indexed keywords

DOSIMETRY; IONIZATION; IONIZATION CHAMBERS; MONTE CARLO METHODS; PHANTOMS; SCANNING;

EID: 67650735414     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/54/10/012     Document Type: Article
Times cited : (73)

References (19)
  • 2
    • 41349095522 scopus 로고    scopus 로고
    • Validation of a Monte Carlo tool for patient-specific dose simulations in multi-slice computed tomography
    • Deak P, van S M, Shrimpton P C, Zankl M and Kalender W A 2007 Validation of a Monte Carlo tool for patient-specific dose simulations in multi-slice computed tomography Eur. Radiol. 18 759-72
    • (2007) Eur. Radiol. , vol.18 , Issue.4 , pp. 759-772
    • Deak, P.1    Van S, M.2    Shrimpton, P.C.3    Zankl, M.4    Kalender, W.A.5
  • 3
    • 41049096079 scopus 로고    scopus 로고
    • Three-vessel coronary artery disease examined with 320-slice computed tomography coronary angiography
    • Dewey M, Zimmermann E, Laule M, Rutsch W and Hamm B 2008 Three-vessel coronary artery disease examined with 320-slice computed tomography coronary angiography Eur. Heart J. 29 1669
    • (2008) Eur. Heart J. , vol.29 , Issue.13 , pp. 1669
    • Dewey, M.1    Zimmermann, E.2    Laule, M.3    Rutsch, W.4    Hamm, B.5
  • 4
    • 34547450740 scopus 로고    scopus 로고
    • Experimental validation of a versatile system of CT dosimetry using a conventional ion chamber: Beyond CTDI100
    • Dixon R L and Ballard A C 2007 Experimental validation of a versatile system of CT dosimetry using a conventional ion chamber: beyond CTDI100 Med. Phys. 34 3399-413
    • (2007) Med. Phys. , vol.34 , Issue.8 , pp. 3399-3413
    • Dixon, R.L.1    Ballard, A.C.2
  • 6
    • 17844396202 scopus 로고    scopus 로고
    • The calibration of experimental self-developing Gafchromic HXR film for the measurement of radiation dose in computed tomography
    • Gorny K R, Leitzen S L, Bruesewitz M R, Kofler J M, Hangiandreou N J and McCollough C H 2005 The calibration of experimental self-developing Gafchromic HXR film for the measurement of radiation dose in computed tomography Med. Phys. 32 1010-6
    • (2005) Med. Phys. , vol.32 , Issue.4 , pp. 1010-1016
    • Gorny, K.R.1    Leitzen, S.L.2    Bruesewitz, M.R.3    Kofler, J.M.4    Hangiandreou, N.J.5    McCollough, C.H.6
  • 7
    • 51549088875 scopus 로고    scopus 로고
    • Converting dose-length product to effective dose at CT
    • Huda W, Ogden K M and Khorasani M R 2008 Converting dose-length product to effective dose at CT Radiology 248 995-1003
    • (2008) Radiology , vol.248 , Issue.3 , pp. 995-1003
    • Huda, W.1    Ogden, K.M.2    Khorasani, M.R.3
  • 8
    • 70350681944 scopus 로고    scopus 로고
    • IEC 2002 Medical electrical equipment: Part 2-44. Particular requirements for the safety of x-ray equipment for computed tomography IEC 60601-2-44
    • (2002)
  • 9
    • 0030022315 scopus 로고    scopus 로고
    • Calculation of computed tomography dose index to effective dose conversion factors based on measurement of the dose profile along the fan shaped beam
    • Jansen J T, Geleijns J, Zweers D, Schultz F W and Zoetelief J 1996 Calculation of computed tomography dose index to effective dose conversion factors based on measurement of the dose profile along the fan shaped beam Br. J. Radiol. 69 33-41
    • (1996) Br. J. Radiol. , vol.69 , Issue.817 , pp. 33-41
    • Jansen, J.T.1    Geleijns, J.2    Zweers, D.3    Schultz, F.W.4    Zoetelief, J.5
  • 11
    • 0037325935 scopus 로고    scopus 로고
    • Patient dose in cardiac computed tomography
    • McCollough C H 2003 Patient dose in cardiac computed tomography Herz 28 1-6
    • (2003) Herz , vol.28 , Issue.1 , pp. 1-6
    • McCollough, C.H.1
  • 12
    • 0036831529 scopus 로고    scopus 로고
    • AAPM/RSNA physics tutorial for residents: Topics in CT. Radiation dose in CT
    • McNitt-Gray M F 2002 AAPM/RSNA physics tutorial for residents: topics in CT. Radiation dose in CT Radiographics 22 1541-53
    • (2002) Radiographics , vol.22 , Issue.6 , pp. 1541-1553
    • McNitt-Gray, M.F.1
  • 13
    • 17844409887 scopus 로고    scopus 로고
    • Enlarged longitudinal dose profiles in cone-beam CT and the need for modified dosimetry
    • Mori S, Endo M, Nishizawa K, Tsunoo T, Aoyama T, Fujiwara H and Murase K 2005 Enlarged longitudinal dose profiles in cone-beam CT and the need for modified dosimetry Med. Phys. 32 1061-9
    • (2005) Med. Phys. , vol.32 , Issue.4 , pp. 1061-1069
    • Mori, S.1    Endo, M.2    Nishizawa, K.3    Tsunoo, T.4    Aoyama, T.5    Fujiwara, H.6    Murase, K.7
  • 14
    • 43449126798 scopus 로고    scopus 로고
    • Initial evaluation of coronary images from 320-detector row computed tomography
    • Rybicki F J et al 2008 Initial evaluation of coronary images from 320-detector row computed tomography Int. J. Cardiovasc. Imaging 24 535-46
    • (2008) Int. J. Cardiovasc. Imaging , vol.24 , Issue.5 , pp. 535-546
    • Rybicki, F.J.1
  • 15
    • 0019485556 scopus 로고
    • A method for describing the doses delivered by transmission x-ray computed tomography
    • Shope T B, Gagne R M and Johnson G C 1981 A method for describing the doses delivered by transmission x-ray computed tomography Med. Phys. 8 488-95
    • (1981) Med. Phys. , vol.8 , Issue.4 , pp. 488-495
    • Shope, T.B.1    Gagne, R.M.2    Johnson, G.C.3
  • 17
    • 34347388838 scopus 로고    scopus 로고
    • 16-slice CT: Achievable effective doses of common protocols in comparison with recent CT dose surveys
    • Van Der Molen A J, Veldkamp W J and Geleijns J 2007a 16-slice CT: achievable effective doses of common protocols in comparison with recent CT dose surveys Br. J. Radiol. 80 248-55
    • (2007) Br. J. Radiol. , vol.80 , Issue.952 , pp. 248-255
    • Van Der Molen, A.J.1    Veldkamp, W.J.2    Geleijns, J.3
  • 18
    • 34347388838 scopus 로고    scopus 로고
    • 16-slice CT: Achievable effective doses of common protocols in comparison with recent CT dose surveys
    • Van Der Molen A J, Veldkamp W J and Geleijns J 2007b 16-slice CT: achievable effective doses of common protocols in comparison with recent CT dose surveys Br. J. Radiol. 80 248-55
    • (2007) Br. J. Radiol. , vol.80 , Issue.952 , pp. 248-255
    • Van Der Molen, A.J.1    Veldkamp, W.J.2    Geleijns, J.3
  • 19
    • 70350653875 scopus 로고
    • Zankl M, Panzer W and Drexler G 1991 The calculation of dose from external photon exposures using reference human phantoms and Monte Carlo methods: Part VI. Organ doses from computed tomographic examinations GSF-Bericht 30/91 Neuherberg, Germany: Gesellschaft für Strahlen- und Umweltforschung
    • (1991) GSF-Bericht 30/91
    • Zankl, M.1    Panzer, W.2    Drexler, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.